Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAdmitted-Finance V P O MANPURA TEHSIL BADDI DISTT SOLAN H P | SOLAN | HIMACHAL PRADESH | 171102 | L1 | Admitted-Finance | |
| 2 | L2₹63.1 L+₹29.7 L (89.1%)Admitted-Finance 1286 3 SHASHRI NAGAR MEERUT | MEERUT | L2 | Admitted-Finance | |
| 3 | L3₹66.1 L+₹32.8 L (98.2%)Admitted-Finance NIL | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | mohd anwar L3 | ARUN ELECTRICALS INDIA L2 | M/S AMAN ELECTRICAL AND ENGG WORKS L1 |
|---|---|---|---|---|---|---|
| 1.00Electrical Part A 33 KV Line to Kut Bounger | ||||||
| 2.00 | Steel Tubular Poles with base plate (13 m, Working Load > 227 kg) (with Ruling Span 90 m, 10 No. Run thro' and 3 No. Dead End Structures per KM ) | 106 | No | 12,500 ₹13,25,000 | 10,000 ₹10,60,000 | 8,000 ₹8,48,000 Lowest |
| 3.00 | Muffs with concerete filling | 106 | No | 450 ₹47,700 | 450 ₹47,700 | 290 ₹30,740 Lowest |
| 4.00 | ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3Φ and Additional 3% (Sag, Jumpering and wastage} | 15.62 | Km | 65,000 ₹10,15,365 | 65,000 ₹10,15,365 | 20,000 ₹3,12,420 Lowest |
| 5.00 | Earth wire (GI, 6 SWG) {Includes 2 wire lengths and Additional 3% (Sag and wastage)}@ 150 kg/km | 1,710 | Kg | 25 ₹42,750 | 25 ₹42,750 | 20 ₹34,200 Lowest |
| 6.00 | 33 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per single pole structure | 153 | No | 150 ₹22,950 | 150 ₹22,950 | 50 ₹7,650 Lowest |
| 7.00 | Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 2 No sides) / Dead structures. | 78 | No | 200 ₹15,600 | 200 ₹15,600 | 150 ₹11,700 Lowest |
| 8.00 | X-Arm: - MS Channel Iron: 3050x125X65x5, Length Tolerance in length - (+) 30 mm on either side (74 No.) | 222.65 | m | 250 ₹55,662.5 | 250 ₹55,662.5 | 100 ₹22,265 Lowest |
| 9.00 | X-Arm: - MS Channel Iron: 3300x125X65x5, Length Tolerance in length - (+) 30 mm on either side (for guarding) (55 No.) | 181.5 | m | 250 ₹45,375 | 250 ₹45,375 | 100 ₹18,150 Lowest |
| 10.00X-Bracing Set - MS Angle Iron: [2(4000x50x50+ 2200x65x65x 6mm] 2 Tolerance I length -(+) 30 mm on either side (53 Set) | ||||||
Tender Value
Refer Docs
EMD Value
₹4.4 L
Closing Date
21 May 2021, 5:00 pmClosed
Chief Engineer Operation Central Zone HPSEBL Mandi
Chief Engineer Operation Central Zone HPSEBL Mandi
Construction of 33 KV line to proposed 33/11 KV Sub station along with 11 KV line and DTRS AT Kut Bounger under ESD Talai, ED Ghumarwin of Operation Circle HPSEBL Bilaspur
2021_HPSEB_47120_1
NIT 05/2021-22
Open Tender
Electrical Works
Turn-key
150 days
Ghumarwin
Tender cost, EMD and Tender qualifying documents along with technocommercial sheets
5 documents required · 5 mandatory
₹5,900
Sr Executive Engineer ED Mandi
₹4.4 L
Chief office Mandi
15 Jun 2021
4 May 2021
24 May 2021
4 May 2021
21 May 2021
16 May 2021
13 May 2021 - 15 May 2021
15 May 2021
Amount
Electrical Part A 33 KV Line to Kut Bounger
Steel Tubular Poles with base plate (13 m, Working Load > 227 kg) (with Ruling Span 90 m, 10 No. Run thro' and 3 No. Dead End Structures per KM )
Muffs with concerete filling
ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3Φ and Additional 3% (Sag, Jumpering and wastage}
Earth wire (GI, 6 SWG) {Includes 2 wire lengths and Additional 3% (Sag and wastage)}@ 150 kg/km
33 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per single pole structure
Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 2 No sides) / Dead structures.
X-Arm: - MS Channel Iron: 3050x125X65x5, Length Tolerance in length - (+) 30 mm on either side (74 No.)
X-Arm: - MS Channel Iron: 3300x125X65x5, Length Tolerance in length - (+) 30 mm on either side (for guarding) (55 No.)
X-Bracing Set - MS Angle Iron: [2(4000x50x50+ 2200x65x65x 6mm] 2 Tolerance I length -(+) 30 mm on either side (53 Set)
MS Angle Iron: [2(4000x50x50]
MS Angle Iron: [2(2200x65x65x 6mm]
Stay set complete in all respect (83 No.)
Stay Wire (7/4.00 mm) (9.0 kg Per Stay Set) (83 No.)
HT Earthing set complete
Full Clamp for Pole
Eye Hook for earth wire
Half Clamp for Pole
Danger Plate (203X200X1.6mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed wire
Aluminium Paint
33 KV Isolator(2000 A without ES)
B 11 KV HT Line a 11 KV HT Line to at Kut Bounger
Steel Tubular Poles with base plate (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures per Km)
Muffs with concerete filling
AAAC 7/3.81 (80 mm²) {Includes 3 conductor lengths for 3Φ and Additional 3% (Sag, Jumpering and wastage}
A.I. knee bracing set 2x(750x50x50x6)mm for single pole (2No.)
X-Arm MS Channel Iron 100x50x6, Length [1500] mm (1 No.)
X-Arm MS Channel Iron 100x50x6, Length [2400] mm (4 no.)
A.I. bracing set for double pole structure 2(2700x50x50x6mm+1500x50x50x6mm) (2 No.)
A.I. X-arm for Guarding (1800x50x50x5) mm (1 no.)
A.I. X-arm for Guarding (3000x50x50x5) mm (2 no.)
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN):
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
HT Stay set complete in all respect
Stay Wire (7/3.15 mm2) (9.0 Kg per Stay Set)
HT Earthing set complete
Danger Plate (250X200X1.6 mm)
Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Pole Top Bracket
Half Clamp
Full Clmap
Barbed Wire
Aluminium Paint
Earth Hook
b 11 KV HT Line to Gangloh
Steel Tubular Poles with base plate(11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures per Km)
Muffs with concerete filling
AAAC 7/3.81 (80 mm²) {Includes 3 conductor lengths for 3Φ and Additional 3% (Sag, Jumpering and wastage}
A.I. knee bracing set 2x(750x50x50x6)mm for single pole (138 No.)
X-Arm MS Channel Iron 100x50x6, Length [1500] mm (69 No.)
X-Arm MS Channel Iron 100x50x6, Length [2400] mm (30 no.)
X-Arm MS Channel Iron 100x50x6, Length [2400] mm (26 No.)
A.I. bracing set for double pole structure 2(2700x50x50x6mm+1500x50x50x6mm) (13 No.)
A.I. X-arm for Guarding (1800x50x50x5) mm (69 no.)
A.I. X-arm for Guarding (3000x50x50x5) mm (13 no.)
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN):
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
HT Stay set complete in all respect
Stay Wire (7/3.15 mm2) (9.0 Kg per Stay Set)
HT Earthing set complete
Danger Plate (250X200X1.6 mm)
Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Pole Top Bracket
Half Clamp
Full Clmap
Barbed Wire
Aluminium Paint
Earth Hook
11 KV G.O. Switch (400 A, 25 KA without ES)
C 11 KV HT Line to Badhatar
Steel Tubular Poles with base plate (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures per Km)
Steel Tubular Poles with base plate (9 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
AAAC 7/3.81 (80 mm²) {Includes 3 conductor lengths for 3Φ and Additional 3% (Sag, Jumpering and wastage}
X-Arm MS Channel Iron 100x50x6, Length [1500] mm (1 No.)
X-Arm MS Channel Iron 100x50x6, Length [2800] mm (2 No.)
X-Arm MS Channel Iron 75x40x6, Length [2800] mm ( No.) for supporting GO Switch.
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN):
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
HT Stay set complete in all respect
Stay Wire (7/3.15 mm2) (9.0 Kg per Stay Set)
HT Earthing set complete
Danger Plate (250X200X1.6 mm)
Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Pole Top Bracket
Full Clmap
Barbed Wire
Aluminium Paint
Earth Hook
11 KV G.O. Switch (400 A, 25 KA without ES)
C Distribution Transformer a Distribution Transformer (630 KVA, 11/0.4 KV)
Prov. 11/0.4 kV 630 KVA Distribution Transformer
Prov. STP Pole with base plate 9.00 mtr W/L 200 KG
Prov. Muff with Cement Concrete filling
Prov. M.S.C.I. X-Arm (100x50x5 mm),Length 2800 mm X 2 Nos.
Prov. M S C.I. (75X40 X 6 mm), Length : 2800 mm X 4 Nos = 11200 mm=11.20 Mtr for supporting DO fuse unit & G.O. Switch
Prov. M S A.I X Arm (50X50 X 5 mm) Length 2800 mm x( 1 No. for LA's + 2 Nos. for Distribution Box = 2800 X 3 nos.= 8400 mm= 8.40 Mtr.
Prov. G.O. AB Switch Unit ( 11kV, 400A 25 KA )
Prov. D.O.Fuse Unit
Prov Lightning Arrestor (Surge Arrester, 9kV Station Class Porcelain Type )
Prov. Discs Insulator sets (Comprising 1 No. Disc: ^^ (Porcilain, BS, 12 kV 90 kN) i/c Dead End Clamps etc.)
Prov. Stay Set complete
Prov. Stay Wire 7/4.00 mm ( @6.00 / 9.0 kg Per Stay Set)
Prov. Pipe Earthing set (With G.I. Strips 50x6mm,40x6mmx 25x6mm)
Prov. LT Distribution Panel Box with ACB (1000A, 50 kA, 4P, 1No.) and MCCB 600 Amp 3 Nos
Prov. Half Clamp with Nuts & Bolts (M.S. Flat Iron 50X6 mm)
Prov. Full Clamp with Nuts & Bolts ( M.S. Flat Iron 50X6 mm )
Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers))
Prov. Aluminium. Thimble
Prov. Aluminium. Thimble
Prov. Danger Plate
Prov. Barbed Wire
Prov. Aluminium Paint
Prov. LT Cable (3.5 Core) 500 mm2
b Distribution Transformer (250 KVA, 11/0.4 KV)
Prov. 11/0.4 kV 250 KVA Distribution Transformer
Prov. STP Pole with base plate 9.00 mtr W/L 200 KG
Prov. Muff with Cement Concrete filling
Prov. M.S.C.I. X-Arm (100x50x5 mm),Length 2800 mm X 2 Nos.
Prov. M S C.I. (75X40 X 6 mm), Length : 2800 mm X 4 Nos = 11200 mm=11.20 Mtr for supporting DO fuse unit & G.O. Switch
Prov. M S A.I X Arm (50X50 X 5 mm) Length 2800 mm x( 1 No. for LA's + 2 Nos. for Distribution Box = 2800 X 3 nos.= 8400 mm= 8.40 Mtr.
Prov. G.O. AB Switch Unit ( 11kV, 400A 25 KA )
Prov. D.O.Fuse Unit
Prov Lightning Arrestor (Surge Arrester, 9kV Station Class Porcelain Type )
Prov. Discs Insulator sets (Comprising 1 No. Disc: ^^ (Porcilain, BS, 12 kV 90 kN) i/c Dead End Clamps etc.)
Prov. Stay Set complete
Prov. Stay Wire 7/4.00 mm ( @6.00 / 9.0 kg Per Stay Set)
Prov. Pipe Earthing set (With G.I. Strips 50x6mm,40x6mmx 25x6mm)
Prov. LT Distribution Panel Box with ACB (400A, 50 kA, 4P, 1No.) MCCB 300 Amp 3 Nos.
Prov. Half Clamp with Nuts & Bolts (M.S. Flat Iron 50X6 mm)
Prov. Full Clamp with Nuts & Bolts ( M.S. Flat Iron 50X6 mm )
Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers))
Prov. Aluminium. Thimble
Prov. Aluminium. Thimble
Prov. Danger Plate (11KV)
Prov. Barbed Wire
Prov. Aluminium Paint
Prov. LT Cable (3.5 Core) 240 mm2
c Distribution Transformer (400 KVA, 11/0.4 Kv) a/w CT PT Metering unit
Prov. 11/0.4 kV400 KVA Distribution Transformer
Prov. STP Pole with base plate 9.00 mtr W/L 200 KG
Prov. Muff with Cement Concrete filling
Prov. M.S.C.I. X-Arm (100x50x5 mm),Length 2800 mm X 4 Nos.
Prov. M S C.I. (75X40 X 6 mm), Length : 2800 mm X 4 Nos = 11200 mm=11.20 Mtr for supporting DO fuse unit & G.O. Switch
Prov. C.I (100X50 X 6 mm), Length : 460 mm X 2 Nos. = 920 mm = 0.920 Mtrs. for supporting Main Channel of transformer/ CT-PT
Prov. M S A.I X Arm (50X50 X 5 mm) Length 2800 mm x( 1 No. for LA's + 2 Nos. for Distribution Box = 2800 X 3 nos.= 8400 mm= 8.40 Mtr.
Prov. CT-PT Belting & Knee Bracing
I) M S A.I (50X50x 5 mm), Length: 2800 mm X 4 Nos.= 11200 mm = 11.20 Mtr
II) M S A.I (35X35X 5 mm) Length: 460 mm X 2 Nos.= 920 mm = 0.920 Mtr.
Prov. G.O. AB Switch Unit ( 11kV, 400A 25 KA )
Prov. D.O.Fuse Unit
Prov Lightning Arrestor (Surge Arrester, 9kV Station Class Porcelain Type )
Prov. Discs Insulator sets (Comprising 1 No. Disc: ^^ (Porcilain, BS, 12 kV 90 kN) i/c Dead End Clamps etc.)
Prov. Stay Set complete
Prov. Stay Wire 7/4.00 mm ( @6.00 / 9.0 kg Per Stay Set)
Prov. Pipe Earthing set (With G.I. Strips 50x6mm,40x6mmx 25x6mm)
Prov. LT Distribution Panel Box with ACB (630A, 50 kA, 4P, 1No.) and MCCB 300 Amp 3 Nos and 100 Amp 2 Nos.
Prov. Half Clamp with Nuts & Bolts (M.S. Flat Iron 50X6 mm)
Prov. Full Clamp with Nuts & Bolts ( M.S. Flat Iron 50X6 mm )
Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers))
Prov. Aluminium. Thimble
Prov. Aluminium. Thimble
Prov. Danger Plate (11KV)
Prov. Barbed Wire
Prov. Aluminium Paint
Prov. LT Cable (3.5 Core) 400 mm2
Prov. 11 KV CT-PT combined unit outdoor,Oil Immersed, Class.5 Consisting of three CT on R,Y & B and 1 No. 11KV/110V PT. Accuracy Class 0 .5S - (10-400/5A) - 25/5 Amps
Prov. Energy Meter 3Ø, 3/4 wire CT-PT Operated Static Tri-Vector Meter. (PT ratio-/110V, CT ratio-/5A), Accuracy Class:0.5S, Category-B, DLMS Compliant with RS 232 & RS 485 port.
d Distribution Transformer (250 KVA, 11/0.4 KV) a/w CT PT Metering unit
Prov. 11/0.4 kV 250 KVA Distribution Transformer
Prov. STP Pole 9.00 mtr W/L 200 KG with base plate.
Prov. Muff with Cement Concrete filling
Prov. M.S.C.I. X-Arm (100x50x5 mm),Length 2800 mm X 4 Nos.
Prov. M S C.I. (75X40 X 6 mm), Length : 2800 mm X 4 Nos = 11200 mm=11.20 Mtr for supporting DO fuse unit & G.O. Switch
Prov. C.I (100X50 X 6 mm), Length : 460 mm X 2 Nos. = 920 mm = 0.920 Mtrs. for supporting Main Channel of transformer/ CT-PT
Prov. M S A.I X Arm (50X50 X 5 mm) Length 2800 mm x( 1 No. for LA's + 2 Nos. for Distribution Box = 2800 X 3 nos.= 8400 mm= 8.40 Mtr.
Prov. CT-PT Belting & Knee Bracing
I) M S A.I (50X50x 5 mm), Length: 2800 mm X 4 Nos.= 11200 mm = 11.20 Mtr
II) M S A.I (35X35X 5 mm) Length: 460 mm X 2 Nos.= 920 mm = 0.920 Mtr.
Prov. G.O. AB Switch Unit ( 11kV, 400A 25 KA )
Prov. D.O.Fuse Unit
Prov Lightning Arrestor (Surge Arrester, 9kV Station Class Porcelain Type )
Prov. Discs Insulator sets (Comprising 1 No. Disc: ^^ (Porcilain, BS, 12 kV 90 kN) i/c Dead End Clamps etc.)
Prov. Stay Set complete
Prov. Stay Wire 7/4.00 mm ( @6.00 / 9.0 kg Per Stay Set)
Prov. Pipe Earthing set (With G.I. Strips 50x6mm,40x6mmx 25x6mm)
Prov. LT Distribution Panel Box with ACB (400A, 50 kA, 4P, 1No.) and MCCB 300 Amp 3 Nos.
Prov. Half Clamp with Nuts & Bolts (M.S. Flat Iron 50X6 mm)
Prov. Full Clamp with Nuts & Bolts ( M.S. Flat Iron 50X6 mm )
Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers))
Prov. Aluminium. Thimble
Prov. Aluminium. Thimble
Prov. Danger Plate (LT)
Prov. Barbed Wire
Prov. Aluminium Paint
Prov. LT Cable (3.5 Core) 240 mm2
Prov. 11 KV CT-PT combined unit outdoor,Oil Immersed, Class.5 Consisting of three CT on R,Y & B and 1 No. 11KV/110V PT. Accuracy Class 0 .5S - (10-400/5A) - 25/5 Amps
Prov. Energy Meter 3Ø, 3/4 wire CT-PT Operated Static Tri-Vector Meter. (PT ratio-/110V, CT ratio-/5A), Accuracy Class:0.5S, Category-B, DLMS Compliant with RS 232 & RS 485 port.
A Construction of 630,400 & 250 KVA Transformer foundation
Excavation in foundation,trenches etc.in earth work, lift upto 1.50 metres stacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacked soil in 15 cm.layers, when required in to plinth sides of foundations etc. and then disposing of all surplus excavated earth as directed with in a lead of 20 mtrs. (PW/JW ). 50% each
Providing and laying Cement concrete 1:6:12 (1Cement:6 Sand: 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of centring and shuttering in: foundation and plinth
Providing and laying Cement concrete 1:2:4(1Cement:2 Sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work foundation and plinth
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give fair finish i/c centring,shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs etc.In (i) vertical surface such as walls (any thickness) partitions and the like.
B Providing wooven mesh fencing with steel Gate & locking arrangement around 630,400 and 250 KVA Transformer
Excavation in foundation,trenches etc.in earth work, lift upto 1.50 metres stacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacked soil in 15 cm.layers, when required in to plinth sides of foundations etc. and then disposing of all surplus excavated earth as directed with in a lead of 20 mtrs. (PW/JW ) 50% each
Providing and laying Cement concrete 1:2:4(1Cement:2 Sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work foundation and plinth
Steel work in single section i/c cutting, hoisting, fixing in position and applying a priming coat of red paint in R.S. joists, channels, angles etc.
Supply and fixing wovenplane G I wire fencing of mesh 50mm to 150mm to any type of standard rails, straining bolts.etc. including provision of binding wire staples etc.
P/F M.S pressed butt hinges with necessary screws -75 x 47 x 1.70mm
Providing & fixing oxidized M.S. sliding door bolt with bolts and nuts, screws etc. complete (Size 250x16mm)
ARUN ELECTRICALS INDIA
mohd anwar
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .