Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹27.6 L+₹4.9 L (21.8%)Rejected-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹28.3 L+₹5.7 L (25.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹27.8 L
EMD Value
₹55,500
Closing Date
28 Jan 2019, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
AS PER BOQ AND TENDER DOCUMENTS
2019_MES_230821_1
GE FORT KOCHI/8602
Open Tender
Civil Works
Item Rate
365 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹55,500
Yes
22 May 2021
4 Jan 2019
29 Jan 2019
5 Jan 2019
28 Jan 2019
17 Jan 2019
5 Jan 2019 - 16 Jan 2019
Amount
M & L repairs to unserviceable street/security lights fittings of LED, of any wattage and size by taking down from poles/buildings after disconnecting the electric connection, replace the unserviceable drive ,PVC connector etc, cleaninng, refixing the light fittings at its original position after rectifying the defects and connecting to street light feeder including testing complete all as specified and directed. Note :- (i) Replacement of parts like drive , will be measured and paid seperatily as supply only (ii) The cost of labour ,tools and minor spares required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
M & L repairs to unserviceable Post Top Lantern / CFL lamp fittings / Bulk Head fittings/Flood lights by taking down from poles/wall/roof after disconnecting the electric connection, replace the unserviceable parts refixing the light fittings at its original position after rectifying the defects and make it operational complete all as specified and directed. Note :- (i) Replacement of parts like ballast,lamp,ignitors/drive will be measured and paid seperatily as supply only (ii) The cost of labour and tools required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
Supply only LED drive suitable for LED street light 60/72/80W 230V , all as specified and directed .
Supply only LED drive suitable for LED street light 90W 230V ,all as specified and directed .
Supply only LED drive suitable for LED Flood light 120W 230V all as specified and directed .
S & F doom post top lantern LED type 12V 230V all as specified and directed Make :-Cat Part No HPLLEDPDC12W of HPL or its equivalent in Havells/ Bajaj/ Philips/Wipro /Crompton
Supply only open construction ballast for HID lamps 70W 230V SON/MH all as specified and as directed .
Supply only 70W high pressure sodium vapour elliptical coated lamp all as specified and directed .
Taking down unserviceable street light/flood light luminaires post top lantern of any type and capacity from existing pole / tower/ building complete, all as specified and as directed .
Supply and fix LED street light fitting 60 W preessure die cast alluminum alloy for housing (heat sink) for effective thermal management,sturdiness & excellent corrotion resistant,Heigh efficiency long life LED lumen efficiency of >/130lum/watt with PC lens to ensure to better unifomity of light distribution,Spread-(beam angle alnong the drive way)-160 degree,Throw( beam angle across the drive way) -110 digree,Asymmetrical batwing epoxy powder coated gray after phosphochramate treatment ,inbuilt electronic driver with APFC and THD</10% surge protection up to 5 KV all as specified and as directed . Make:-Havells Cat Part No ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent in Philips/Crompton/HPL//Wipro/Bajaj
S & F LED flood light fitting with high power LED with die cast aluminium, IP 65 protection, 50 watts including fixing arrangement for walls / poles complete all as specified.nd as directed . LED, 5000K Make- Cat Part No JETACOMPECTOFL50WLED757LTG of Havells or equivalent in Philips / Wipro / Grompton Greaves
S & F in replacement of 200x160x98mm PVC junction box having IP 65 protection with metric knockouts for 16/25 sqmm cable entry with terminalals /bus bar 4 pole including provn of one MCB 6 Amps to 32 Amps 'SP C' series,240 Volts, having breaking capacity 10 kA dual termination, mid trip ,all as specified and as directed. Make Sintex/Hensel
S & F 2 core, 6 Sqmm PVC flat weather proof aluminum cable including taking down old unserviceable cable of any size complete all as specified.
S & F 2 core, 10 Sqmm PVC flat weather proof aluminum cable including taking down old unserviceble cable of any size complete all as specified.
M & L applying a coat of Cement base paint to PCC Pole 9 metre long and writing pole number with synthetic enamel paint (White with black base) including applying a coat of aluminium paint to FI Clamps/ Brackets/Cross Arms including preparation of old PCC Pole / steel surface complete all as specified. complete all as specified.
M & L preparation of old steel surfaces over 10cm width or girth not otherwise described and applying a coat of synthetic enamel paint to steel tubular pole complete all as specified.
Supply and fix in repair PVC insulated 3 core copper conductor cable of size 1.5 Sqmm sheathed 1100 volts conforming to IS 694 fron junction box to street light fitting , all as specified and directed
Supply and fix in repair GI bracket made out of GI pipe 50mm dia medium grade, 1.5 mtr long bent to shape and fixing on poles with MS clamps of suitable sizes etc complete, all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out in soft /loose soil complete all as specified.
M & L Returning and filling in of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified.
M & L Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified.
M&L sand cushioning in trenches using clean dry river sand for cable cushioning all as specified and as directed. Note : Thickness of sand cushioning after punning down will be measured and paid.
Supply and fixing / laying in repair GI tubing 50mm dia light grade for cable protection all as specified and directed .
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
Supply and errect Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom,class 10( SBE/ISI make approved).including taking down old unserviceable concrete pole,all as directed Note:- Earth work and foundation measured and paid seperatily
M & L PCC 1 : 4 : 8, type D-2, using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed
M & L PCC 1:3:6, type C-1, using 20mm graded stone aggregate as in coping for pole including necessary form work complete all as specified.and directed
Demolition of cement concrete unreinforced in ground floors and pavings not exc 15 cm thickness (below or above ground level) for laying UG cable complete all as specified and directed
M & L 100mm thick, PCC 1 : 2 : 4, type B-1, (using 20mm graded stone aggregate) as in flooring / filling of road cutting etc complete all as specified.and directed
Supply and lay LT cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoued , electric power cables (heavy duty) 1100 volts with stranded aluminium conductor of size 4 core16 sqmm laid in trenches,ducts etc all as specified.and directed
Supply and lay LT cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoued , electric power cables (heavy duty) 1100 volts with stranded aluminium conductor of size 2 core 16 sqmm laid in trenches,ducts etc all as specified.and directed
Supply and lay LT cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoued , electric power cables (heavy duty) 1100 volts with stranded alum inium conductor of size 2 core 10 sqmm laid in trenches,ducts etcall as specified.and directed
Suply and lay XLPE cable 1100 volts grade, armoured, insulated and sheathed with multistranded aluminium conductor conforming to IS specifications of size 3.5 core 150 Sqmm and laid in ground, trays, through pipes, on walls, floors etc complete all as specified.and directed
Suply and lay XLPE cable 1100 volts grade, armoured, insulated and sheathed with multistranded aluminium conductor conforming to IS specifications of size 3.5 core 95 Sqmm and laid in ground, trays, through pipes, on walls, floors etc all as specified.and directed
Suply and lay XLPE cable 1100 volts grade, armoured, insulated and sheathed with multistranded aluminium conductor conforming to IS specifications of size 3.5 core 70 Sqmm and laid in ground, trays, through pipes, on walls, floors etc all as specified.and directed
Suply and lay XLPE cable 1100 volts grade, armoured, insulated and sheathed with multistranded aluminium conductor conforming to IS specifications of size 3.5 core 50 Sqmm and laid in ground, trays, through pipes, on walls, floors etc all as specified.and directed
Suply and lay XLPE cable 1100 volts grade, armoured, insulated and sheathed with multistranded aluminium conductor conforming to IS specifications of size 3.5 core 35 Sqmm and laid on walls, floors fixed with shaddle ,clamp etc all as specified.and directed
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for heat shrink straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for heat shrink straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 150 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for heat shrink straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 Sqmm to 300 Sqmm complete all as specified.
S & F 50mm dia GI pipe, light grade, as in cable protection including taking up old unserviceable pipe complete all as specified.
S & F 80mm dia GI pipe, light grade, as in cable protection including taking up old unserviceable pipe complete all as specified.
M & L preparation of old steel surfaces over 10cm width or girth not otherwise described and applying a coat of synthetic enamel paint to LT feeder pillar box complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI strip 32x6mm mm by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
S & F MCCB with Fixed Thermal* & Fixed Magnetic setting | Ics = 100% of Icu 250 Amps 4 pole having breaking capacity 36 kA in existing panel compatible with existing MCCB in fit and finish including taking out old unserviceable MCCB complete all as specified.
S & F MCCB with Fixed Thermal* & Fixed Magnetic setting | Ics = 100% of Icu 200 Amps 4 pole having breaking capacity 36 kA in existing panel compatible including taking out old unserviceable MCCB complete all as specified
S & F MCCB with Fixed Thermal* & Fixed Magnetic setting | Ics = 100% of Icu Four Pole 160 Amps having breaking capacity 25 kA in existing panel compatible including taking out old unserviceable MCCB complete all as specified
S & F MCCB with Fixed Thermal* & Fixed Magnetic setting | Ics = 100% of Icu Four Pole, 125 Amps having breaking capacity 25 kA in existing panel compatible including taking out old unserviceable MCCB complete all as specified
S & F MCCB withFixed Thermal* & Fixed Magnetic setting | Ics = 100% of Icu Four Pole 100 Amps having breaking capacity 25 kA in existing panel compatible including taking out old unserviceable MCCB complete all as specified
Taking down old UG cable of any size all as specified and directed
M&L for locating the fault of LT cable manually or with the help of necessory fault locating instruments including disconnecting connection both side and reconnecting the same after rectify the defect on the same day all as directed by Engineer-in-Charge. Note : If contractor failed to provide the necessory T & P including manpower after receiving the complaint Rs: 500/per hour per complaint will be recovered from the contractor.
Taking out from trenches, Testing of LT UG Cables, carrying out of jointing works and relaying of UG cable nominal crosss section Area of 10 to 35 sqmm 2/3.5/4 core jointing kit incl connecting and disconnecting complete all as specd and directed.
Taking out from trenches, Testing of LT UG Cables, carrying out of jointing works and relaying of UG cable nominal crosss section Area of 50 to 95 sqmm 3.5 core jointing kit connecting and disconnecting complete all as specd and directed.
Taking out from trenches, Testing of LT UG Cables, carrying out of jointing works and relaying of UG cable nominal crosss section Area of 120 to 240 sqmm 3.5 core jointing kit connecting and disconnecting complete all as specd and directed.
S&Joining LT Cable jointing kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cable of size upto 10/16 Sqmm 2 core all as directed
S&Joining LT Cable joining kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cable of size upto 10 Sqmm to 16 Sqmm 3.5/4 core all as specd and directed.
M & L pre cast cement concrete block masonry with solid blocks type C1, 1:3:6 using 20 mm size graded stone aggregatge , exc 10 cm in width and set in cement mortar 1;6 complete including demolition of existing masonary all as specified and as directed.
S & F Mild steel work in framed work such as grills, Gates, framed guard bars, gratings, ladders, Cable trays, Fencing etc., with ends of bars welded and/ riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O including taking down old rusted steel work all as specd and directed.
M&L double wall HDPE Corrugated flexible pipe heavy duty of internal dia 80 mm incl all accessories in walls or laying in trenches including taking down of damaged pipes, all as specd and directed. Make:- Apollo, Jain, gamson,.
M&L double wall HDPE Corrugated flexible pipe heavy duty of internal dia 50 mm incl all accessories in walls or laying in trenches including taking down of damaged pipes, all as specd and directed. Make:- Apollo, Jain, gamson,.
Supplying and laying 80mm GI tubing light grade incl all accessories for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works incl taking down old GI tubing all as specified and directed
All as per item No 62 here in above but for 50mmm bore
All as per item No 62 here in above but for 40mmm bore
All as per item No 62 here in above but for 32mmm bore
Supply and fix in repairs G I strip 32 x 6 mm burried in ground laid in floor fixed to wall on PVC/Epoxy saddles etc .
Routine Maintenance and minor overhauling/periodic servicing of DG sets on-site complete to engine and alternator, consisting of normal periodic repairs, whenever specified by opening of head, checking of pulleys/belts, checking desired output values of alternator, and checking for any defects, allignment and rectification of the same, replacement of necessary gaskets incl top gasket, valves and alligning to ensure smooth operation. replacement of defective / worn out parts by new spares such as filters, gaskets , V belts, rubber hoses , worm drive clamps ,nuts & bolts and cleaning of alternator with vaccum cleaner including complete lubrication of moving parts for DG Set 500 KVA capacity in various locations of Zone B:- Note : - Spares except Gaskets and seals, Lubrication required for above maintenance will be measured and paid in relevant item.
All as per item No 67 here in above but for DG Set 380 KVA capacity
All as per item No 67 here in above but for DG Set 200 KVA capacity
All as per item No 67 here in above but for DG Set 100 to 160 KVA capacity
All as per item No 67 here in above but for DG Set 75 KVA capacity
All as per item No 67 here in above but for DG Set 20 KVA capacity
Supply only Air filter element with O ring suitable for DG Set 500 KVA capacity all as directed.
All as per item No 73 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 73 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 73 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 73 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 73 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply only oil filter assembly including element with O ring suitable for DG Set 500 KVA capacity all as directed.
All as per item No 79 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 79 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 79 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 79 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 79 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply only fuel filter element-assembly suitable for DG Set 500 KVA capacity all as directed.
All as per item No 85 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 85 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 85 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 85 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 85 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply only Radiator fan belt set suitable for DG Set 500 KVA capacity all as directed.
All as per item No 91 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 91 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 91 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 91 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 91 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply only battery charging alternator belt suitable for DG Set 500 KVA capacity all as directed.
All as per item No 97 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 97 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 97 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 97 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 97 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply only coolant circulating rubber hose pipe set with rust-proof hose clamps and all connectors suitable for DG Set 500 KVA capacity all as directed.
All as per item No 103 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 103 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 103 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 103here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 103 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply only Turbo charger repair kit complete suitable for DG Set 500 KVA capacity all as directed.
All as per item No 109 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 109 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 109 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 109 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 109 here in above but suitable for DG Set 20 KVA capacity all as directed.
Calibration and overhauling of fuel injection pump and complete injection system incl injectors from the authorised dealer to make the FIP functional incl tuning it in the engine to receive optimum exhaust out put for DG Set 500 KVA capacity all as directed.
All as per item No 115 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 115 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 115 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 115 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 115 here in above but suitable for DG Set 20 KVA capacity all as directed.
Dismantling of radiator, overhauling & cleaning by descaling with acid, removal of leakage by welding brazing & refixing it duly repaired complete for DG Set 500 KVA capacity all as directed.
All as per item No 121 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 121 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 121 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 121 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 121 here in above but suitable for DG Set 20 KVA capacity all as directed.
M & L Preparation of old steel surfaces of any description for DG Sets and alternator after scrubbing of rusted surfaces and applying with two coats of synthetic enamel desired metallic paint by spray painting complete for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 127 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 127 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply and fixing in replacement water pump including seals/gaskets with necessary washers for DG Set 500 KVA capacity,complete all as directed.
All as per item No 130 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 130 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 130 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 130 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 130 here in above but suitable for DG Set 20 KVA capacity all as directed.
Supply and fixing in repairs 12/24 Volts self starter assembly including pinion, solenoid switch complete suitable for DG Set 500 KVA capacity,complete all as directed. Make: Lucas/Siemens/Bosch/Minda/TVS.
All as per item No 136 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 136here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 136 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 136 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 136 here in above but suitable for DG Set 20 KVA capacity all as directed.
M &L for repair / overhauling of self starter incl. replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for DG Set 500 KVA capacity,complete all as directed.
All as per item No 142 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 142 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 142 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 142 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 142 here in above but suitable for DG Set 20 KVA capacity all as directed.
M &L for fixing in repairs automatic voltage regulator complete all as directed for DG Set 500 KVA capacity,
All as per item No 148 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 148 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 148 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 148 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 148 here in above but suitable for DG Set 20 KVA capacity all as directed.
M & L Preparation of old steel surfaces of Sound proof enclosures of any description after scrubbing of rusted surfaces and applying with two coats of synthetic enamel desired metallic paint by spray painting complete for DG Set 100 to 160 KVA capacity all as directed.
M&L in repairs Engine-Alternator coupling assembly with bushings complete suitable for DG Set 500 KVA capacity,
All as per item No 155 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 20 KVA capacity all as directed.
M&L in repairs Anti vibration mounting pads including complete mounting accessories complying to existing dimensions for DG Set 500 KVA capacity, Make:- Dunlop/Goodyear/MRF/Michellin.
All as per item No 155 here in above but suitable for DG Set 380 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 200 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 100 to 160 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 75 KVA capacity all as directed.
All as per item No 155 here in above but suitable for DG Set 20 KVA capacity all as directed.
M&L for topping up of coolant anti-freeze in pre-mixed condition brought to site in sealed containers and topping up of the same when and where as directed in DG Sets of capacities 20 to 500 kVA as required at site.
M&L for topping up of distilled water zero TDS, brought to site in sealed containers and topping up of the same when and where as directed in batteries of capacities upto 180 Ah as directed by Engr in Charge.
M&L for fixing in repairs, push button suitable for 230/12 Volts AC/DC as required at site incl making connections complete all as directed.. Make:- C&S/ Schneider/ Ashwin/L&T.
M&L for fixing in repairs, metric water temperature gauge including sensor and cable complete all as directed. Make:- Pricol / Yenkey.
M&L for fixing in repairs, metric oil pressure guage including sensor and cable complete all as directed. . Make:- Pricol / Yenkey.
M&L for fixing in repairs, LED Indicator lamps of desired colour 230/12 Volts AC/DC as required at site incl making connections complete all as specified and as directed. Make:- C&S, Schneider, Ashwin/L&T.
M&L for fixing, installation, testing and connecting of Flooded cell Lead Acid Battery of capacity 180 Ah 12 volts with charged/discharged and water level indicators including taking down of old damaged battery, all as specified. and as directed.
M&L for fixing, installation, testing and connecting of Flooded cell Lead Acid Battery of capacity 88 Ah 12 volts with charged/discharged and water level indicators including taking down of old damaged battery , all as specified
M&L for fixing in repairs, battery lead 120 sqmm single core multistranded copper conductor cable, red and black for positive and negative terminals respectively incl making of necessary connections from battery to self starter using copper lugs of adequate size, all as specified. and as directed..
M&L for fixing in repairs, battery lead 70 sqmm single core multistranded copper conductor cable, red and black for positive and negative terminals respectively incl making of necessary connections from battery to self starter using copper lugs of adequate size, all as specified. and as directed.
M&L for fixing in repairs, battery lead 16 sqmm single core multistranded copper conductor cable, red and black for positive and negative terminals respectively incl making of necessary connections from battery to self starter using copper lugs of adequate size all as specified
M&L for fixing in repairs, Brass Battery clamps/terminals of required size for use in lead acid batteries of upto 180 Ah incl fixing the same to battery posts and making necessary connections as directed.
S & F Heat proof Asbestos rope 12 mm dia on engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding / tightening in leakage exhaust pipe complete all as directed conforming to IS specification fire proof /flame proof all as specified
M&L for cleaning of fuel tanks of DG Sets mounted in any position by draining out fuel and keeping aside in safe custody and refilling of the same after cleaning of deposited sludge and all visible impurities for DG Sets installed at INS Dronacharya and SMA Rameswaram 20-500 kVA all as directed by Engr in charge.
M&L for fabrication in repairs external fuel tank cylindrical or cube shape using 1.6 mm thick CRCA sheet and fixing the same at desired height and location incl application of two coats of epoxy paint over a coat of epoxy primer of desired colour all to the satisfaction of Engr in charge.
M&L for Shifting of DG sets from one location to another (INS Dronacharya to SMA Rameswaram) in case of Emergency, in the event of major faults/failures using all necessary manual and mechanical means incl disconnecting and reconnecting of Distribution cables for capacities upto 380-500 kVA all to the satisfaction of Engr-in-charge.
M&L for Engine Oil 15W40 in sealed HDPE container of 100/50 Litres opened at site and toping up/refilling in DG Sets after draining of unserviceable engine oil by qualified meachanic as and when directed by Engr-in-charge.
AR Traders
General Engineering and Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .