| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33 LAdmitted-Finance NO 13 GROUND FLOOR EVALAPPAN STREET TAMBARAM SANITORIUM KANCHIPURAM TAMIL NADU 600047 | CHENGALPATTU | TAMIL NADU | 600047 | L1 | Admitted-Finance | |
| 2 | L2₹1.2 Cr+₹84 L (254.5%)Admitted-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Admitted-Finance | |
| 3 | L3₹1.3 Cr+₹1.0 Cr (304.8%)Admitted-Finance D II BLOCK MIDC RAMNAGAR CHINCHWAD PUNE MAHARASHTRA 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical TECHNICALLY DISQUALIFIED | |
| 5 | Rejected-Technical | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
Refer Docs
EMD Value
₹3.4 L
Closing Date
5 Dec 2019, 2:00 pmClosed
SMPM
C.NO.62, MPM DEPT., NAVAL DOCKYARD MUMBAI.
UP-GRADATION OF 03 IN NOS. 250KW (220V) DC RECTIFIER UNITS 400 KW (200 TO 400 VDC) DC RECTIFIER UNITS AT SUBSTATION-3 OF SOUTH WHARF FOR C.NO. 60, YAS DEPT. AT NAVAL DOCKYARD MUMBAI.
2019_NAVY_297103_1
DYT/CC/0154/10/19-20/103(A)6
Open Tender
Miscellaneous Services
Multi-stage
180 days
C.NO.60, YAS DEPT., AT NAVAL DOCKYARD MUMBAI.
AS PER RFP
4 documents required · 4 mandatory
₹0
₹3.4 L
Yes
C.NO.60, YAS DEPT.
17 Mar 2020
13 Nov 2019
6 Dec 2019
13 Nov 2019
5 Dec 2019
13 Nov 2019
13 Nov 2019 - 20 Nov 2019
21 Nov 2019
Amount
Opening of Soft patch (RCC Cover), Disconnection and removal of existing 250KW DC rectifier units (Qty-03 Nos) and its accessories from substation -03 for upgradation
Provisioning, factory trials and full load trials at shop floor at ND(MB) of 400KW (200 to 400VDC) DC rectifier units (Qty-03 Nos) meeting following specifications per rectifier unit :- i) Input - 415V (+/-10%), 50Hz(+/-2%), 3 Phase (3 Wire) ii) Output Voltage - 200VDC to 400 VDC Step less iii) Current - 1000AMP iv) Transformer KVA - 2 x 260 KVA Continuous v) Ripple - Less than 3% RMS of rated output at full load and nominal AC input voltage. vi) Control - 2 nos. of 3 phase full wave fully control SCR controlled 12 pulse bridge. Regulation: +/-1% of rated output current from 100Amp to 1000Amp. vii) Indication - Mains ON, Rectifier ON, Charger ON, SCR Fuse fail, Transformer & Devices overtemp. Indicator, single Phase/Phase Failure Indication. viii) Protection - Surge protection for SCR, line Fuse for SCR, Thermostat for over temp. for SCR & Transformer. ix) Cooling - force air cooled by fans. x) Internal Wiring - All wires of LFH (DEF. STANDARD. NES 518 & IS 694 GEN.) Grade multistrand flexible of 1.5/0.5 sq.mm of 1100V grade for internal wiring, with electrolytic annealed grade copper bus bar of adequate rating. xi) Hardware - SS316 grade xii) Main Parts of DC Power Supply - - 3 pole, 1000Amp ACB for input – 03 Nos (01 each) - Main step down Transformers - 06 Nos (02 each) and IPT - 03 Nos (01 each) - SCR Bridge for AC to DC conversion and current control – 06 Nos (02 each) - Filter chokes - 03 Nos (01 each) - 3 pole, 400 Amp MCCB for output – 12 Nos (04 each). - Digital Meters for input & output Voltage & current control – 06 Nos (02 each) xiii) Cable Entry - from the bottom of the cabinet. xiv) IP Protection for Indoor Installation – IP56 xiii) Operating conditions - Max Temp. 50°C Max, Humidity: 95% non Condensing with Max Ambient temp. not occurring simultaneously,
Painting details – Two coats of anticorrosive paints and two coats of epoxy paint (powder coated-spray printing) shade – RAL 7032 (Siemens Grey) for upgraded DC rectifier units (Qty-03 Nos)
Fitment and connectorisation of upgraded rectifier Units (Qty-03 Nos) at Substation-3 of south wharf jetty with associated cabling, accessories and updated wiring diagram
Closing of soft patch (RCC Cover) and waterproofing of the soft patch of substation-3
In-situ trials and commissioning of the DC rectifier units (Qty-03 Nos) as per approved QAP
Transportation charges
Chakshu Enterprise
ADOR DIGATRON PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .