Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.8 LAccepted-AOC D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L1 | Accepted-AOC Since lowest | |
| 2 | L2₹87.6 L+₹11.9 L (15.7%)Rejected-Finance HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | L2 | Rejected-Finance Since not lowest bidder | |
| 3 | Rejected-Technical 45 58 5 15A AKSHAYA NARASIMHANAGAR VISAKHAPATNAM 530 024 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530024 | - | Rejected-Technical Requisite documents not submitted |
Tender Value
₹76.5 L
EMD Value
₹89,825
Closing Date
14 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
Office of HQ Chief Engineer (CG) Visakhapatnam-530007
As per BOQ
2022_MES_570602_2
CE (CG)/VIZ/TOKEN16 OF 2022-2023
Open Tender
Civil Works - Others
Item Rate
120 days
BHUBANESWAR
As per tender documents
7 documents required · 7 mandatory
₹1,000
Garrison Engineer I CG Bhubneswar
₹89,825
Yes
31 Mar 2023
16 Feb 2023
16 Mar 2023
16 Feb 2023
14 Mar 2023
2 Mar 2023
Amount
SCHEDULE 'A' PART -I (MISC B/R WORKS)
M&L for Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc n.exc 15mm average thickness from ground floor to 3rd floor.
M&L for Cutting openings through Old masonry walls built in Cement mortar for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for under pinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises
M&L for Making good under cills (or over arches, lintels and bressummers) including all pinning as necessary in cement mortar 1:4
M&L for Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement.
S&F 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite from ground floor to 4th floor
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified.
M&L for Preparation of old treated surfaces of wall and applying one coat of white wash complete all as specified
M&L for Preparation of old treated surfaces of wall and applying one coat of Oil bound distemper complete all as specified
SCHEDULE 'A' PART -II (LIFT WORK)
(g) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.(h) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery.(j) Decorative ceiling panel light (LED)(k) One sleek circular PVC heavy duty fan in false ceiling make for manufacturer.(l) continuous earting for machine and equipment.(m) Steel wire rope of adequate size as per relevant IS and as per manufacturer specification.(n) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes control panel, locks governor, car operational panel power control and trailing cables complete.(o) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage.
Note 2: (a) The bidder to visit the shafts where lift is to be installed. (b) The lift Machine is to be installed above the shaft. (c) Addition alteration to the approach of the lift machines is to be done in the rate quoted. (d) Lift panel and Machine should be easily accessible for repair and Maintenance. (e) Locking arrangement to the lift machine room is to be provided in the rate quoted. (f) defect liability period will be two years from the date of completion / commissioning . (g) Cost of spares required during DLP will be arranged by the contractor. (h) Comprehensive maintenance of the lift during the defect liability period is responsibility of the contractor and the quoted rate deemed to be included against this item.
M&L for earthing complete with M.S galvanized earth plate electrode 600 x 600 x 6 mm thick burried directly in ground ( earth pit not less than 2.25 metre deep below normal GL) with top edge of the earth plate not less than 1.5 metre below normal GL. connected to galvanized earth strip 32 x 6 mm dia by means of bolts , nuts, check nuts & washers of GI or steel including excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6mm dia bar, 3 Nos both way, 40 mm dia light grade GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia medium grade ,lugs, main Earthing lead upto 7.5 mtr including Charcoal dust , salt etc. all as shown in electrical plate No. 3 of SSR part -1, 2009 specification.
M&L for earth continuity conductor or main earthing strip 25 x 4 mm dia Galvanised Iron strip fixed to wall on batten or recessed or burried in ground or drawn in conduit/ pipe all as required at site complete all as specified and as directed. Make: Polycab/Gloster/Havells
Supply and laying underground XLPE insulated screened PVC bedded galvanized steel strap or wire armoured heavy duty electric power cable with aluminum conductor 1100 volt grade cross sectional area 50 Sq mm 3.5 Core complete all as directed. Make: Polycab/Gloster/Havells
Supply and laying underground XLPE insulated screened PVC bedded galvanized steel strap or wire armoured heavy duty electric power cable with aluminum conductor 1100 volt grade cross sectional area 25 Sq mm 4 Core complete all as directed. Make: Polycab/Gloster/Havells
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line etc complete all as specified and directed for laying of cable, erecting of poles, stay and pipe line, complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified.
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engineer-in-Charge.
M&L for MCCB 3 Pole .415 V. fixed type,100 Amps with breaking capacity 16 KA in existing LT panel all as specified and directed by Engineer-in-charge. Make: L&T/Legrand/Havells
Supply & fixing testing and commissioning CPRI approved LT panel board out door type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out from 3.15 mm thick CRCA sheet powder coated mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs/MCBs, cable glands of suitable sizes for incoming and outgoing cables complete all as specified and directed including the necessary PCC work and with and including following :- (a) MCCB 100 Amp,36 KA,4 Pole-01 No (Incomer from Existing Panel) (b) MCCB 40 Amp,16KA,4 Pole-03 No (Outgoing for 2 Nos of new lift & one spare) (c) MCB SPN 32 amps-01 No.(d) LED indicator lamp set of 3(e) Voltmeter digital type with of (0-440) Volt- 1 No (f) Ammeter digital type ( 0 to 100 Amps)- 1No
SCHEDULE 'A' PART -III (COMPREHENSIVE MAINTENANCE OF LIFT WORK)
(a) AMC on 1st year after expiry of defects liability period.
(b) AMC on 2nd year after expiry of defects liability period.
(c) AMC on 3rd year after expiry of defects liability period. Notes for Serial Item Nos -27 to 30 above :- (i) Unit rate quoted is deemeded to be inclusive of comprenhensive maintaince for two lifts per one month.
Notes :- (i) The rate quoted are deemed to include all/any charges related to renewal of lift license and lift insurance from State Govt/Other Agency.(ii) The rate is inclusive of all items as required at site including any spares to keep the lift operated all the time.(iii) The Maintenance of the lifts should be done through the OEM.(iv) The contractor should attend the complaint/breakdown immediately.(v) Maintenance of the lift should be done as per manufacturer instructions
UNIVERSAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .