| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹43.7 L+₹5.3 L (13.7%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Due to higher rate | |
| 3 | L3₹47.1 L+₹8.6 L (22.5%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance Due to Higher rate. |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
27 Dec 2024, 12:00 pmClosed
SE, PWD, Kolkata Electrical Circle
P-16, India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Vertical Extension of existing Hostel Building from 4th Floor to 7th Floor at West Bengal Judicial Academy, New Town, Kolkata-700160-SITC of split type AC machines and allied works.
2024_WBPWD_778201_1
PWD/SE/KEC/NIT-18/24-25
Open Tender
A/C ORG
Item Rate
45 days
WBJA, Newtown
Please refer Tender documents.
8 documents required · 8 mandatory
₹80,000
Office of the SE, PWD, Kolkata Electrical Circle
19 Mar 2025
3 Dec 2024
30 Dec 2024
3 Dec 2024
27 Dec 2024
13 Dec 2024
11 Dec 2024
Amount
Supply, Installation, Testing and Commissioning of Inverter type Split AC machine having Cooling Capacity range (6.8 kw - 7.7 kw) with variable speed Rotary compressor, Refrigerant gas R32 / R410A, BEE star rating - 3, (ISEER range 3.5 to 3.99), Air flow range CFM (780 - 880 or better), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 139 l (Part-I & Part-II) with all amendments (Make - O-General, Model: ASGG24CPTB-B(R.-32) / MITSUBISHI HEAVY, Model: SRK24YYM-W6 / Mistubishi Electric, Model: RJS22VF) as per choice of E.I.C. (at Ground floor & lst floor of Club House)
Supply, Installation, Testing and Commissioning of Inverter type Split AC machine having Cooling Capacity range (5.2 kw - 5.6 kw) with variable speed Rotary compressor, Refrigerant gas R32 / R410A, BEE star rating - 3, (ISEER range 3.5 to 3.99), Air flow range CFM (600 - 780 or better), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 139 l (Part-I & Part-II) with all amendments (Make - O-General, Model: ASGGI8CPTB-B (R-32) / MITSUBISHI HEAVY, Model: SRK18YXP-W6 / Mistubishi Electric, Model: RJSI8VF) as per choice of E.I.C.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
S & F 1.1 KV grade, PVC insulated & unsheathed 3 Core 2.5 Sqmm Copper flexible Cable for Indoor to outdoor connection as per direction of EIC.
S & F of Single Phase automatic Stabilizer for inverter AC machine (Upto 2.0 Ton) and necessary connection. Specification Input Voltage Range. 130 V -280 V. Current Capacity. 15 Ampere. Application: One Inverte AC Up to 2 Ton or 24000 BTU/Hour Time Delay: 3 Minutes ± 20 Seconds lTDS(Intelligent Time Delay System) Digital display for electrical parameter monitoring. EMI filter protection Intelligent Time Delay System Mounting Type:- Wall Mounting. Wananty:-3 Year. (make- Microtech/Hitachi RYOKU/ V-guard Model-VWI500)
Supply & Laying 20mm dia PVC flexible Drain Pipe(Good quality) for draining of water from AC machines.
Supply & Laying PVC Drain Pipe 25mm dia with 6mm thick nitrile rubber insulation (Make-supreme/Ori-Plast)
Supply & fixing of of 40mm UPVC pipe on wall with saddles and other accessories as required and mending good the damages to building works as per direction of EIC.(Mk.-Supreme/Skipper/Florex)
Supply and fixing of 40mm UPVC pipe elbow(Mk.-Supreme/Skipper/Florex)
S & fixing of 40mm UPVC pipe TEE (Mk.-Supreme/Skipper/Florex)
S and fixing of 40mmUPVC pipe couplingMk.-Supreme/Skipper/Florex)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. Note: N.B: (a) The Agency must procure the materials from the Manufacturer / OEM or from their authorized sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. (b) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. (c) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. (d) Rates are inclusive of all taxes and duties including GST & LWC.
Lyric International (BID ID -5920266)
MILLENNIUM AIRCON (BID ID -5904085)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .