| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.8 L+₹2.0 L (7.98%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Being other than lowest | |
| 3 | L3₹28.1 L+₹3.3 L (13.1%)Rejected-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L3 | Rejected-AOC Being other than lowest | |
| 4 | L4₹30.7 L+₹5.9 L (23.6%)Rejected-AOC H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-AOC Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
7 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
PROVN OF PERIMETER SECURITY LIGHTS AT CERTAIN LOCATIONS, LIGHTENING PROTECTION, FLAME PROOF LIGHTS AND FANS TO CERTAIN BUILDINGS AT AF STN HIGHGROUNDS
2023_MES_602040_1
CWE/AF CHD/CHD/T-02/2023-24
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per NIT
7 documents required · 7 mandatory
₹500
AGE(I)(AF) Highgrounds
₹70,000
12 Sept 2023
8 Jun 2023
14 Jul 2023
8 Jun 2023
7 Jul 2023
23 Jun 2023
Amount
EXTERNAL ELECTRIFICATION
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and as directed.
All as per item No. 1.01 here-in-before but exc 1.5 metre and not exceeding 3.0 metre deep complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying bricks common burnt clay sub class 'B' old size laid dry for cable protection, complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation filling, complete all as specified and directed.
Material and Labour for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate cast-in-situ as mass filling and coping of poles and struts, stay around the poles etc all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point complete all as specified and directed.
Demolition of cement concrete (unreinforcement) as in coping /foundation of poles and other similar work including removal of rubbish outside MOD land complete all as specified.
Supply and laying / fixing , GI pipe light grade 50mm bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including flat iron clamp, nut, bolt, wahser etc of required size with and including taking out old unserviceable protection pipe & complete all as specified and directed. Note: Boring of holes under road etc. if required as per site requirement shall deemed to be included in the quoted rates
Supply and laying / fixing in replacement HDPE (DWC) pipe of outer dia not less 50 mm fixing on poles, walls, under floors, road, drain crossing, laying on surface etc complete all as specified and directed and as per direction of Engr-in-Charge.. Note: Rates quoted shall be inclusive of all items and accessories , bend, joints, nut bolts, clamps etc as required as per site requirements.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 50 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, removing, returning filling and pipe will be measured and paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, removing, returning filling and pipe will be measured and paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Supply and errection in true vertical position steel tubular swaged pole type 410 SP-22 , 8.5 mtr long complete with cast iron base plate and finial taper plug, bolts, nuts, washers and screws incl painting with synthetic anamelled aluminium paint two coat over one coat of red oxide primer after errection and providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole all as specified and as directed by Engr-in-charge. Note: (i) Earth work and PCC shall be measured and paid separately. (ii) Serial No and description in different tint as directed by Engr-in-Charge shall be marked on each pole without any extra cost.
Supply and fixing in replacement of LED street light fittings of 60-62 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, IP 66 protection suitable for pole mounting E17 LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, built in surge protection of up to 5kV with facility of power supply making proper electric connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge.
Material and labour for Cross arms, bracing, supports, clamps and back plates fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer with and including dismantling old unservicable cross arma coms lete all as specified and directed.
Supply and laying PVC insulated flexible unarmoured cable three core with copper conductor 1.5 Sqmm size 1100 volt grade from junction box to security light through PVC conduit incl complete connection all as specified and directed by Engr-in-Charge.
Supply and fixing Rigid non-metallic PVC conduit of external dia 20mm exclusive of boxes (junction/ terminal) incl fixing on poles for security light flexible cable with & including clamps etc for fixing on poles complete all as specfied and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire (all as shown in Plate No. 2 on SSR Part I 2009) to the earthing test point all as specified and indicated including testing on completion complete all as specfied & directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh, watering pipe, earth lead protection pipe deemed to be included in the quoted rate.
Supply and fixing of MCCB, four pole, 125Amps, 415 volts, 16 KA, 16Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
S & F KIOSK box weather proof made out of PVC , pole mounted, hinged door size 333 x 233 x 200mm out side and 300 x 200 x 105mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp including clamps with necessary MS nuts bolts and washer complete all as directed.
S & F in replacement of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 8 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Beutral loss & Phase reverse incl Power contactors (3 nos) and incoming (3 nos of capacity 32 amps each)- outgoing MCB(3 nos of capacity 32 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 02EC8kW3P-VMS or equivqlent model in Schneider/Havells/Legrand Make (i)Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof,FR rade) (v) Circuit wiring-Polycab/Finolex Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of minimum of 1 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box shall be iincluded in the quoted quoted rates.
Supply and fix in replacement, on-load change over switch four pole, 200Amp in steel sheet enclosure, complete all as specified and directed.
Supply & Fixing Busbar Chamber of size not less than 400x400x300mm with set of 04 aluminium busbar 200 Amps rating each fixed on suitable insulators with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. Bus bar chamber shall be fixed on 04 nos of legs made with MS Angle iron 40x40x6mm. Length of each leg shall be not less than 600mm. The Chamber shall be fixed more than 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engr in charge.
Supply and fixing MCCB sheet metal enclosure on wall/surface/Penal/concealed in wall as per site complete all as per direction of Engr-in-charge.
S & F of street light bracket made out of GI pipe 32mm bore light grade suitable to fit with LED street light approx length not less than 120 cm bent to shape including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed. Note: Rate quoted shall be inclusive of necessary clamps, nut & bolts etc
FLAME PROOF LIGHTING
M&L for Flame proof point wiring zone I&II gas group 11A/11B PVC insulated unsheathed multistranded copper conductor FRLSH cable using two single core 1.5 Sq.mm (nominal area) in and including 20mm dia metallic stove enamalled steel conduit concealed including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified and as directed.
Supply and fixing switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed
Supply and fixing flame proof Ceiling fan 1200mm sweep single phase 240V 50 Hz and making connection with flexible three core pvc insulated copper conductor cable 1 sqmm of required length from ceiling rose complete all as specified and as directed
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories with and including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed
Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, complete all as specified and directed.
LIGHTENING PROTECTION
Supply and fixing Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as spd and directed by Engr-in- charge
Supply and fixing aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in- charge
Supply and fixing Galvanised iron strip 32 x 6mm buried in ground complete all as specified and directed by Engr-in- charge
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in- charge
Supply and fixing GI pipe light grade 32mm bore with all fittngs and fixed complete to walls and ceilings all as specified and directed
M&L Providing, cement concrete type B1 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel , protrcted by galvanised Iron pipe 40mm bore medium grade and watering pipe 20mm bore light grade with funnel and wire mesh with and including necessary earth work/excavation, PCC chamber in PCC 1:3:6 type C2 and RCC cover complete all as shown in electrical plate No. 3 of SSR Pt-I (2009) connected to earthing test point including testing complete all as specified and directed. Note:RCC Pit cover shall be of RCC 1:2:4 Type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of cast iron.
M/s badrinath Traders
GULSHAN SINGH GHAI AND SON
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .