Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAccepted-AOC PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹6.8 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹7.2 Cr+₹32.9 L (4.80%)Rejected-Finance | ₹7.2 Cr+₹32.9 L (4.80%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹7.4 Cr+₹55.2 L (8.07%)Rejected-Finance HOUSE NO 2 BYELANE ANJALI UPA PATH AJANTA PATH SURVEY P O BELTOLA GUWAHATI 781028 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781028 | ₹7.4 Cr+₹55.2 L (8.07%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹8.0 Cr+₹1.2 Cr (17.4%)Rejected-Finance MAZUMDER LANE VILL P O BERENGA PT II P S SILCHAR DIST CACHAR ASSAM 788005 | SILCHAR | CACHAR | ASSAM | 788005 | ₹8.0 Cr+₹1.2 Cr (17.4%) | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | VARNI BUILDERS L1 | Gravell L3 | BAYAJ UDDIN MAZUMDER L4 | M/S YESHI THINLEY L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE "A" Part - I
(BUILDINGS/STRUCTURES WORK)
Details of Buildings are given here-in-before:- | 1 | Lump sum | 5,68,00,000 ₹5,68,00,000 Lowest | 6,30,00,000 ₹6,30,00,000 | 6,40,10,000 ₹6,40,10,000 | 5,90,00,000 ₹5,90,00,000 |
| 2.00 | SCHEDULE "A" PART- II
(SITE CLEARANCE AND DEVELOPMENT)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 2,19,359.77 ₹2,19,359.77 Lowest | 3,00,000 ₹3,00,000 | 3,10,000 ₹3,10,000 | 2,92,479.69 ₹2,92,479.69 |
| 3.00 | SCHEDULE "A" PART- III
( INTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 19,37,527.74 ₹19,37,527.74 | 19,00,000 ₹19,00,000 Lowest | 21,00,000 ₹21,00,000 | 19,37,527.74 ₹19,37,527.74 |
| 4.00 | SCHEDULE "A" PART-IV
( INTERNAL WATER SUPPLY )
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 2,26,742.6 ₹2,26,742.6 | 1,98,000 ₹1,98,000 | 1,80,000 ₹1,80,000 | 1,71,774.7 ₹1,71,774.7 Lowest |
| 5.00 | SCHEDULE "A" PART- V
(ROAD/PATH/CULVERT)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 10,90,224.95 ₹10,90,224.95 | 10,00,000 ₹10,00,000 | 8,40,000 ₹8,40,000 | 7,78,732.11 ₹7,78,732.11 Lowest |
| 6.00 | SCHEDULE "A" PART- VI
(AREA DRAINAGE)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 3,22,090.76 ₹3,22,090.76 | 3,00,000 ₹3,00,000 | 3,10,000 ₹3,10,000 | 2,87,581.04 ₹2,87,581.04 Lowest |
| 7.00 | SCHEDULE "A" PART- VII
(SEWAGE DISPOSAL)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 1,82,996.03 ₹1,82,996.03 | 1,54,600 ₹1,54,600 | 1,35,000 ₹1,35,000 | 1,26,204.16 ₹1,26,204.16 Lowest |
| 8.00 | SCHEDULE "A" PART- VIII
(EXTERNAL WATER SUPPLY)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 4,08,027.1 ₹4,08,027.1 | 3,75,648 ₹3,75,648 | 3,45,000 ₹3,45,000 | 3,16,300.08 ₹3,16,300.08 Lowest |
| 9.00 | SCHEDULE "A" PART- IX
(EXTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 4,35,305.99 ₹4,35,305.99 | 3,50,000 ₹3,50,000 Lowest | 3,90,000 ₹3,90,000 | 3,56,808.19 ₹3,56,808.19 |
| 10.00 | SCHEDULE "A" PART- X
(FIRE FIGHTING SYSTEM)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 5,67,298.91 ₹5,67,298.91 | 5,87,000 ₹5,87,000 | 3,35,000 ₹3,35,000 | 3,11,702.7 ₹3,11,702.7 Lowest |
Tender Value
₹5.9 Cr
EMD Value
₹6.2 L
Closing Date
18 Sept 2025, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF DEFICIENT MARRIED ACCN FOR AIRMEN AT AF ATN TEZPUR PH I
2025_MES_712817_1
88668/TEZ/E8
Open Tender
Civil Works
Lump-sum
545 days
Tezpur
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE(AF) Tezpur
₹6.2 L
Yes
28 Nov 2025
5 Jun 2025
20 Sept 2025
30 Jun 2025
18 Sept 2025
4 Sept 2025
Amount
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
SCHEDULE "A" PART- II (SITE CLEARANCE AND DEVELOPMENT) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- X (FIRE FIGHTING SYSTEM) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- XI (LIFT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- XII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- XIII (HOT WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule and Sch 'A' Part IX is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION Supply and fixing Modular metal fluxh box with modular white cover plate with frame 8 module complete all as directed and specified.
S&F LED lamp 10 Watt, complete all as directed and specified.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including street light GI pipe bracket of medium grade 40mm dia. ,1.5m long bend to required size and shape including two coat of aluminum paint over a coat of red oxide primer complete in all respect all as specified and directed.
S&F concealed MCCB distribution box, double door, vertical type, TPN, 415V, 8 way, IP 43 suitable for MCCB of 100 Amps, 4P, 25 kA as incomer and MCB SP/TP as outgoing complete with suitable bus bar, neutral link, earth link complete all as specified and directed. Note : (i) MCCB/MCBs shall be measured and paid separately (ii) Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
Supply and fix MCCB 230 Volts, 4 pole, 100 Amp, 50Hz, 25 KA with thermal magnetic release complete all as specified and as directed.
S&F MCB SPN 20 Amps (C-Curve), breaking capacity 10 kA, 240 volts complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (light grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate. (For Internal and External Electrification)
INTERNAL WATER SUPPLY S&F brass angle stop cock CP high pressure with capstan head long shank screwed down 15mm dia. bore, complete all as specified and directed.
S&F brass CP two way angle valve of 15mm dia., complete all as specified and directed.
External Water Supply Supply & fixing 50 mm dia bore Cast Iron Air Valves with single air outlets, bearing specification as per IS 14845 and fixing up in GI water supply mains of size 50 mm dia., complete all as specified and as directed.
Supply and fixing DOL 3 phase Starter for 05 HP Capacity, complete all as specified and as directed.
Supply and fixing Gun metal gate valve/glove valve ISI marked with Iron wheel head screwed both end for GI tubing of size 25 mm dia for iron pipe and fixed, complete all as specified and as directed.
M&L for construction of brick massonry valve pit chamber of inner dimension 120x120x120 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, 15mm thick rendering in CM 1:4, coping in PCC 1:2:4 type B-1, including necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement, complete all as specified and directed.
M&L for cutting and screwing exsisting steel tubing for alterations or additionsdone in position without taking down of 100/80mm dia. pipe, complete all as specified and directed.
EXTERNAL ELECTRIFICATION Horizontal boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, of any length, complete all as specified and as directed.
Supply and fixing double compression medium duty armoured brass cable gland for fixing armoured cable in panel of size 3.5 core 50 sqmm to 70 sqmm, complete all as specified and as directed.
Supply and fixing double compression medium duty armoured brass cable gland for fixing armoured cable in panel of size 3.5 core 95 sqmm to 120 sqmm, complete all as specified and as directed.
Supply and fixing double compression medium duty armoured brass cable gland for fixing armoured cable in panel of size 2 core 6 sqmm to 16 sqmm, complete all as specified and as directed.
Supply and fix cable route indicators of size as specified and as directed by Engineer in Charge.
M&L for outdoor industrial factory made pedestal type cubical panel board of size 1500x1500x600 mm made out of MS sheet 3.15 mm thick & surface provided by equal angle 50x50x5mm protection paneling for instrument/electrical items by 2mm thick MS sheet including surface painted with powder coated ionized spray paint by spraying including filling cavities of pillar, 2 coats of painting after primary coat (red oxide) , front and back opening with locking arrangement . Provision of danger notice board and the following electrical items including all connection , grouting etc. LT panel with following accessories :- Note:-Contractor should submit the drawing for approval of GE befor Procurement
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate. (For External Electrification, Lightning Protection and DG Set)
FIRE FIGHTING SYSTEM Supply and fixing 50mm bore gun metal, automatic air release valve suitable for domestic water supply, complete all as specified and directed.
Supply and fix 20 mm dia branch pipe with nozzle for hose reelbearing specification as per IS 8090, complete all as specified and directed.
Supply and installation of Fire Extinguisher, dry chemical powder (ABC)type of 6 kg capacity with gun housing, complete all as specified and directed.
Supply and fixing 4 Pole MCCB 16 Amps 10 KA 415V with MCCB enclosure complete all as specified and as directed. (For Fire Fighting System and DG Set)
Supply and installation of Fire Extinguisher, water sprinkler of 9 ltr capacity with gun housing, complete all as specified and directed.
LIFT Supply and fixing 4 Pole MCCB 40 Amps 16 KA 415V with MCCB enclosure, complete all as specified and as directed. (For Lift and DG Set)
Supplying, installation of silent Diesel Engine Driven generating set 415 volt, 3 phase 4 wire 0.8 PF,engine as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for Automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation of capacity 30 KVA Comprising and including of following:- (A) DIESEL ENGINE: Water cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete with following:- (a) Radiator with blower fan or heat exchangar with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter complete with first filling of lub oil (iii) Bypass filter (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type replaceable air cleaners and vacuum indicators. (j) Residential silencers.
Serial Item No. 43.00 (Contd....) (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC 'C' class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class (s) Self starter (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) Battery as per manufacturer recommendation. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500 RPM (v) Engine hours (vi) Frequency. (vii) Voltage. (viii) Safety control (Trip and indication). (ix) High water temperature (x) Low lube oil temperature & (xi) Overspeed stop
Serial Item No. 43.00 (Contd....) (c) Suitable battery charger connected to load side to charger battery including connecting leads. (Note: AMF Panel shall be installed out side the acoustic enclosure). (E) BASE PLATE: Common fabricated base frame for engine & alternator made from structural Steel channel, jerk proof on PCC 1:2:4 type B1 foundation including adequate number of anti-vibration pads in adequate quantity all as per the recommendation of the manufacturer. (Note:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor). (F) DIESEL STORAGE TANK: Fuel tank of MS sheet of capacity not less than 12 Hrs continuous operation on full load with fuel level guage, drain plug, locking arrengements, etc including connection to Engine through fuel filter/ manual feed pump as per manufacturer recommendation. (G) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and power coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, laveling certification etc as laid down in GSR No.371(E) dt 17 May 2002 or latest. (H) MISC: Tool kit operation, maint cat, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturers standard practice. (j) PCC foundation for DG Set to be provided as per OEM standard foundation drawing and foundation cost shall deemed to be included on the quoted rate. (k) Adequate diesel and load bank for 12 Hrs fall load testing shall be provided by the contractor during testing and commissioning of DG Set.
M&L for earthing complete with copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to copper strip as earthing lead of size 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (light grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate.
Supply and fixing MCCB VTPN DB, 6 way double door 415V, IP 43 for mounting of enclosure, complete all as specified and directed.
Supply and fixing 4 Pole MCCB 63 Amps 16 KA 415V, complete all as specified and as directed.
Serial Item No. 50.00 (Contd....) Notes: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES and the cost of the same is deemed to be included in the quoted rate for Smart Energy Meters. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry minimum 5 years warranty. (d) The OEM would need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. The OEM should provide complete support to MES to be able to integrate the AMI infrastructure with any IS 16444 compliant meters and connected accessories such as RF/GPRS/Hybrid Infrastructure including supporting software without any extra cost to the department.
Serial Item No. 52.00 (Contd....) (iv) Occupation and Vacation Module: Provision to enter admin controls for transfers/vacations. The system would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (v) Customer Module: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis. (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case tally with incomer EB energy meter. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export:The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself.
Serial Item No. 52.00 (Contd....) (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Notes - The additional functional requirements of MDMS are as follows: (A) Asset Management: i) Meter Location (Apartment, shop, industry/address etc). ii) Consumer Information (Name, Account, ID etc) iii) Meter details (Meter No. 1 phase/3 phase, with or without relay etc). iv) Meter Configuration (Demand integration period, load profile capture period etc). v) GIS information (connection, feeder/transformer/pole etc) (B) Meter data: i) Schedule and on demand meter reads and pinging of meter. ii) Storage of all connected meter events and alarm. (storing of 5 years data or more via archiving) iii) Provide complete history and audit trail for all data for 30 days (configurable period) iv) Handle net metering/meters at the same premises. v) Manage at a minimum 15 minutes interval data.
Serial Item No. 52.00 (Contd....) (C) Data validation, Estimation and Editing (VEE): i) Registered Read Data: Daily Billiing Cycle, as well as derived billing determinants like TOU. ii) Interval Data: Variable intervals and variable units of measure. iii) Calculated Data: Derived or computed such as determinants billing and aggregated loads. iv) Event Data: Event and alarm data from meters, network equipment and MDMS itself. (D) Billing Determinants: i) Configuration multiple TOU/TOD options by customer type, day type (Weekend, Weekdays, and holidays) and by season. ii) Processing of interval data into billing determinants. a) Total consumption b) Consumption in different time blocks for TOU billing. c) Maximum demand (KW and KVA) d) Number of tamper counts e) Average power factor f) Ability for check metering, sub metering prepaid metering and net metering. (E) Exceptions: i) Capture and log data exceptions, problems and failures and send emails/SMS. ii) Generate exceptions for a) Meter tamper alerts b) Communication module health alerts c) Communication is less/more than pre-defined average consumption d) Negative consumption e) Power Outage f) Demand/Load g) Renewable Energy/EV
Serial Item No. 52.00 (Contd....) (H) Reporting: i) Daily data collection report. ii) Usage exceptions iii) VEE validations failures. iv) Physical meter events (install, remove, connect, disconnect) and meter resent report. v) Meter flags. vi) Meter inventory. vii) Defective meters. viii) Interface exception reports between MDM and other subsystems eg. billing, outage etc.
HOT WATER SUPPLY S&F 15mm nominal size, non rising spindle type fancy bib tap as per IS 8931:1993, one way long body, made of cast brass including knob, knob components, diverter & components, nickel-chromium plated finish, complete all as specified and directed.
S&F 15mm bore, stop valve, cast copper alloy, fancy types, chromium plated, screwed down, high pressure with long shank and cup (Concealed type) screwed both ends for steel pipe for unions, complete all as specified and directed.
S&F 15mm bore, GI/steel pipe medium grade and connection including GI fittings in short lengths, complete all as specified and directed.
Comprehensive maintenance of lift for 1st year after expiry of 02 yrs defect liability period installed at AF Stn Tezpur in reliable safe and efficient operating condition through MOU with OEM by regularly examining, lubricating and adjusting the equipments and carry out planned maintenance in systematic and controlled manner suitable for serving Ground + 3 floors (total four landings) 13 Passanger (844 Kg) Lift with electric power operated doors, auto electric levelling device installed complete all type of mechanical and electrical items, governor sleeve, gears, gear shaft assembly, bearings, brake contact, brake shoe liner, brake magnets, governor jaws, sheave or main rope, trailing cable, speed governor rope, all type of electric motors, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, car and counter weight guide rails and buffers, wire, lugs, nut, bolts, screws, hand rails, light luminaries, ventilating fan, hooter, lubricant, gear oil, aircord, rollers, landing wheel, aircord wheel, rubber bush, rail guide shoe, infra red door sensors, automatic door operating system, travelling cables, ARD, Batteries, car doors, landing gates, door sills, 3-Way intercom system, CVT, all types of control panel PCBs, transducers, transformers, rectifires, phase sequence corrector & single phase preventer, relays & cards etc and all machine works i.e. welding, cutting, drilling etc as and when required incl sunday and holidays, during 1st year after completion of defect liability period, complete all as directed to entire satisfaction of Engineer-in-charge.
Srl Item No. 61.00 Contd... Comprehensive, preventive, periodical maintenance after completion of defects liability period and attending day to day complaints for smooth functioning of lifts/elevators (01 Nos) installed at Blocks mentioned here in under:- (a) Bldg No. Airmen Md Accn((AFS Tezpur)- (01 Nos Lifts). Note :- (i) Comprehensive maintenance will start only after completion of 02 years of defect liability period, complete all as directed to entire satisfaction of Engineer-in-charge. (ii) Any Maintenance/replacement of any items during 02 years of defect liability period will be borne by the contractor. Note for item No 1.00 : - (i) The entire work relating to comprehensive, preventive and periodical maintenance of lifts/elvators (including supply of spares) as mentioned above, shall be got executed through the manufacturer from whom the new lifts/elevators are procured. (ii). The cost of all kind of replaced defective part(s) / spare(s) / control card(s) / oil / lubricants etc or any other component(s) / item(s) whether mentioned or not mentioned here-in-before, as and when required to make the lift/elevator fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor on this account. (iii). The comprehensive / preventive / periodical maintenance includes monthly, inspection/testing as per service manual or as per IS standard. The inspection / test report will be submitted to GE.
Srl Item No. 61.00 Contd... (iv) The contractor will have to submit MOU existing OEM within 15 days of date of commencement of work , failing which the contract will be liable to be cancelled and work shall be executed at risk & cost of the contractor. (v) Contractor will conclude AMC for contract with OEM and copy of the agreement will be submitted to Engineer-in-Charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (vi) The above maintenance include complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as required for smooth and efficient functioning of the equipment/lift. (vii) The OEM will also detail one technical staff to inspect the lift every week. regarding its functioning operation or any other issue arising in the lift.Technician should always carry service tool along with himself during each weekly visit. (viii) Sufficient stores should be kept in stock with OEM to address the problem/complaints immediately. (ix) Contractor to note that monthly service will not be paid for the building undergoing special repairs/ unoccupied buildings and no penalty shall be imposed upon contractor, or all as per direction of Engr-in-Charge. (x) All existing earthing of the lifts shall be watering of all existing earthing of the lifts and cheacking for functional shall be done by the contractor to the entire satisfaction of the Engr-in-Charge. (xi) Comprehensive maintenance of lift during defect liability period (02 Yrs after complition of work) shall deemed to included in quoted rates and noting extra shall be given to contractor for the same.
All as per Srl item No. 61.00 here-in-before but for 2nd year after complition of 02 yrs defects liability period
All as per Srl item No. 61.00 here-in-before but for 3rd year after expiry of 02 yrs defects liability period
M/S YESHI THINLEY (BID ID -3429126)
Gravell (BID ID -3421441)
BAYAJ UDDIN MAZUMDER (BID ID -3422245)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.rar
Tender Documents • 23.63 MB
Tenderdocument_2.rar
Tender Documents • 17.20 MB
BOQ.xls
BOQ • 0.36 MB
Tenderdocument_3.rar
Tender Documents • 15.34 MB
Tenderdocument.pdf
Tender Documents • 4.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .