Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance JAKHANI BAND PO BIN PITHORAGARH UK PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
22 Mar 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RWD DIVISION PITHORAGARH
EE RWD DIVISON PITHORAGARH
RAJKIY KUTKUT PRICHETRA BIN MI NEW HECHRI HOUSE KA NIRMAN KARY AT BIN
2021_RES_31023_4
2649 Dated 06-03-2021
Open Tender
Civil Works - Buildings
Item Rate
300 days
BIN
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
Yes
EE RWD DIVISON PITHORAGARH
₹54,000
Yes
25 Mar 2021
8 Mar 2021
23 Mar 2021
8 Mar 2021
22 Mar 2021
8 Mar 2021
90 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Providing and laying in position cement concrete of specified grade cost of centring and shuttering - -All work upto plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth i levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Reinforced cement concrete work in excluding shuttering, finishing and reinforcement--- 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Substructure
Reinforced cement concrete work in excluding shuttering, finishing and reinforcement--- 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Superstructure
Centring and shuttering including strutting,ropping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete.
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Brick work with F.P.S. bricks of class designation 75 in superstruct level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a float cement. 12 mm cement plaster
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 grad finished with a floating coat of neat cement including cement slurry 40mm thick with 20mm nominal size stone aggregate.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
S/F of glass paneswith putty & nails whereever necessary Float glass panes of thickness 4mm
Providing and fixing aluminium handles ISI marked anodised (anod less than grade AC 10 as per IS : 1868) transparent or dyed to req less than grade AC 10 as per IS : 1868) transparent or dyed to req shade with necessary screws etc. complete :125 mm
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete 250x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete 150X10 mm
Providing and fixing aluminium hanging floor door stopper ISI mar (anodic coating not less than grade AC 10 as per IS : 1868) transp required colour and shade with necessary screws etc. complete.Single rubber stopper
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centring, shuttering and finishing. 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A,including jointing with seal ring conforming to IS:5382,leaving 10mm gap for thermal expansion (i) single socket 110 mm dia
Providing and fixing on wall face unplasticised -PVC moulded fittings /accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A,including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5° 110 mm bend
Marble stone flooring with 18 mm thick marble stone, as per sample ofmarble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Excavation in soil in Hilly Area by mechanical means Without useinng Dozer including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWD Uttarakhand specifications
Random Rubble Masonary laid dry in breast wall,retaining wall, parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .