Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.2 L+₹34,070 (1.80%)Rejected-Finance JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹20.7 L+₹1.8 L (9.53%)Rejected-Finance 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹20.8 L+₹1.9 L (10.1%)Rejected-Finance PALACE COMPOUND AGARTALA TRIPURA WEST | GOMATI | TRIPURA | 799013 | L4 | Rejected-Finance L4 |
Tender Value
₹22.1 L
EMD Value
₹44,240
Closing Date
26 Dec 2022, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, installation, testing and commissioning of split window type Air Conditioning system as an emergently required in essential areas of AGMC and GBP Hospital, Agartala for 1 year period during the year 2022 23 during the year 2022 23
2022_CEPWD_35065_1
96/EE/DNIeT/MECH.DIVN/AGT/2022
Open Tender
Electrical Works
Works
365 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹44,240
3 May 2023
12 Dec 2022
26 Dec 2022
12 Dec 2022
26 Dec 2022
12 Dec 2022
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split /window type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
1.0 TR split type high wall AC machine (rated cooling capacity should not be less than 3000 Kcal/hr or 12000 BThu/hr or 3500 watt)
1.5 TR split type high wall AC machine (rated cooling capacity should not be less than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt)
2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt)
1.5 TR window type AC machine (rated cooling capacity should not be less than 4500cal/hr or 18000 Thu/hr or 5250 watt)
Providing star rated (with applicable ISEER according to current industry standard) high wall/ ceiling mounting split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall/ceiling mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 420 volt, 50 Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
2.5 TR split type high wall AC machine ( Minimum 2 star, rated cooling capacity should not be less than 7500 Kcal/hr or 30000 BThu/hr or 8750 watt)
3.0 TR split type high wall AC machine (rated cooling capacity should not be less than 9000 Kcal/hr or 36000 BThu/hr or 10500 watt)
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) ceiling mounting cassette / floor mounting vertical split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall/ceiling mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 420 volt, 50 Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
3.0 TR floor mounting vertical type split AC machine (rated cooling capacity should not be less than 10500 Kcal/hr or 42000 BThu/hr or 10500 watt)
4.0 TR floor mounting vertical type split AC machine (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 BThu/hr or 14000 watt)
Standard installation, testing and commissioning of 1.0/1.5/2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 2.5/3.0/4.0 TR high wall and ceiling mounting cassette type split machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 3.0/4.0 TR floor mounting vertical split type AC machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.0/1.5/2.0 as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 2.5/3.0/4.0 as per manufacturer guideline ( 5/8”,3/8” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
R.P.ELECTRONICS
STANDARD ELECTRONICS
M/S SHISHIR DAS CHOWDHURY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_35614.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .