Loading…
Loading…
Tender Value
₹56.7 L
EMD Value
₹1.1 L
Closing Date
12 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS 2
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; Where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. The Definition of similar nature in this tender means "Any Electrical work related to HT/LT installations". (Authority: PCEE / NWR / JP letter No EL/50/0/SNW/Vol.I Dtd. 08.01.2016).
3 conditions · 1 needing a document upload
Bidder / Tenderer should submit GST registration certificate along with PAN card & Bank mandate while bidding / uploading tender documents.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions
Electrical work in connection with (i) replacement of old/dilapidated quarters by 16 unit Type-III quarters in SMR-MBF Section under ADEN/HQ (ii)Electrical work in connection with improvement of staff quarters in the section of ADEN/Barmer
19Rof2026-27~NWR
19Rof2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹1.1 L
18 Sept 2026
18 Sept 2026
28 Sept 2026
93 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 56,70,332.86 | ||
| — | 1250.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x6 sq mm PVC insulated multi-strand ( 84 /.30 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,54,462.5 | |
| — | 2700.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x4 sq mm PVC insulated multi-strand ( 56 /0.3 mm ) cooper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,36,115 | |
| — | 4120.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x2.5 sq mm PVC insulated ( 36 /0.3 mm ) multi-strand copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,82,961.6 | |
| — | 4600.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class P.V.C. Pipe along with accessories as required in recess on walls/roof properly including cutting of wall /roof and making good the damages as per specifications attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,67,816 | |
| — | 700.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class PVC Pipe along with accessories as required in surface on walls/roof properly with saddles and wooden gutties etc. complete as per specifications attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 36,673 | |
| — | 592.00 | — | — | ||
| Supply, install, test commission of 8Moduler metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,25,913.12 | |
| — | 360.00 | — | — | ||
| Supply, install, test commission of 4Moduler metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,03,557.6 | |
| — | 230.00 | — | — | ||
| Supply, install, test commission of 3Moduler metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil | — | — | — | 50,363.1 | |
| — | 148.00 | — | — | ||
| Supply, install, test &commission of 2 Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 26,884.2 | |
| — | 740.00 | — | — | ||
| Supply, install, test &commission of Modular6amp, 5 Pin Socket as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 99,108.2 | |
| — | 1100.00 | — | — | ||
| Supply, install, test & commission of Modular6amp one way/SP Switch, ISI marked as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 77,176 | |
| — | 540.00 | — | — | ||
| Supply, install, test commissioning of Modular 16 amp, 3/3(6Pin) Socket as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,16,353.8 | |
| — | 540.00 | — | — | ||
| Supply, install, test commission ofModular16 amp one way/SP Switch , 2 Modular ,ISI marked including connection / wiring on lighting switch board as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 79,785 | |
| — | 540.00 | — | — | ||
| Supply, install, test &commission of Modular blank plate as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 6,717.6 | |
| — | 264.00 | — | — | ||
| Supply, install, test commission of Modular type Fan regulator (5step , 2 Modular)including connection/wiring on lighting switchboard as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,31,725.44 | |
| — | 1580.00 | — | — | ||
| Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bell point with single core multi strand copper conductor size 1.5 Sq.mm in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc. As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 6,57,690.8 | |
| — | 60.00 | — | — | ||
| Supply, testing, fixing &commissioning of Exhaust fan 250-300 mm sweep 1200-1440 RPM speed and as per specification attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,36,477.8 | |
| — | 300.00 | — | — | ||
| Supply of material & commissioning of PVC casing caping 25X12 mm with accessories for surface wiring as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 7,335 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mmthick size 600x300x600mmwith suitable MS stand Copper bus bar of 200Acapacity and 2x63A MCB 4pole as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 34,552.98 | |
| — | 160.00 | — | — | ||
| Assembling, fixing, hanging and making connection of Surface pendent mounted box type tube light fitting/street light fitting as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 11,520 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of VTPN DB 8-way enclosure with provision of incoming MCCB of 125A,IP 43/IK09, double door at suitable locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 46,256.94 | |
| — | 3.00 | — | — | ||
| Supply, Fixing of MCCB to be provided in the VTPN given above including supply of material as required & as per specifications attached- MCCB 4-pole 100/125A, 25 KA (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 41,651.7 | |
| — | 280.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB (SP-) 6-32 A (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 67,312 | |
| — | 44.00 | — | — | ||
| Supply, Fixing of RCCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-RCCB - 25 A/30mA two pole (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,11,519.32 | |
| — | 20.00 | — | — | ||
| Supply, Fixing of MCB TP 63A to be provided in the MCB DB including supply of material as required & as per specifications attached (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 41,737.2 | |
| — | 44.00 | — | — | ||
| Supply. fixing, testing and commissioning of SPN DB 8-way with provision of incoming MCB of 63A,IP 43/IK09, double door at suitable locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,12,773.32 | |
| — | 126.00 | — | — | ||
| Supply & fixing of 7W LED Tilt able Mirror light in Aluminium body with glass cover in sand gray finish in 6000k, Approx dimension 320x78x28mm, catalogue no. LLT 004 (make Ledlum, Bajaj, Wipro or equivalent) as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,00,139.76 | |
| — | 26.00 | — | — | ||
| "B" Class 50 mm dia GI pipe earth Station with digging pit & refilling with charcoal & salt as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 36,006.1 | |
| — | 26.00 | — | — | ||
| Inspection Chamber with cover as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 10,026.38 | |
| — | 260.00 | — | — | ||
| Supply & laying of earth connection from earth electrode with 4 mm GI wire properly fixed on wall with wooden gutties etc. as required.(Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,047.2 | |
| — | 1400.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed armoured Aluminium multistrand conductor cable 1100V grade, as per specification attached. 4 Core 16 sq mm (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,49,492 | |
| — | 2000.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed armoured Aluminum multistrand conductor cable 1100V grade, as per specification attached. 4 Core 35 sq mm (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,64,900 | |
| — | 800.00 | — | — | ||
| Supply of cable 4Cx70 sqmm, LT XLPE Cable as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,80,528 | |
| — | 2200.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec (trench work may be on kuchcha/ pucca land and all type of soil as per site requirement and without protective layer of brick). Surface of trench shall be made good in all respect and satisfaction of site engineer. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 89,518 | |
| — | 150.00 | — | — | ||
| laying cable in Air/Wall/Pole etc with fixture(02 nos. per mtrs) as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,648 | |
| — | 2200.00 | — | — | ||
| Supply and laying of HDPE pipe confirming to IS 4984:1995, 50 mm dia, wall thickness 3 mm, PN 6 under the road. The work involves laying cable in HDPE pipe as spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,16,964 | |
| — | 180.00 | — | — | ||
| Drilling of horizontal bore below track/road by pushing method for laying of RCC/HDPE/DWC pipe of various sizes (As per specifications) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,56,366.8 | |
| — | 180.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 160 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,42,277.4 | |
| — | 20.00 | — | — | ||
| Supplying., laying of GI pipe size 50 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 6,881.6 | |
| — | 20.00 | — | — | ||
| Supply of AC single phase static Energy Meter 5-30 A capacity to measure & display of unit (KWH), Ampere (I), Voltage (V), Load (KW), maximum demand (KW) including last six month history of Energy etc. of accuracy class 1.0, 240 V, 50 Hz with backlit LCD display confirming to IS:13779 or latest. Make: Secure, Indotech, L&T, HPL, CG, Genus or similar (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 51,473.6 | |
| — | 5.00 | — | — | ||
| Supply installation, testing and commissioning of 0.5 HP Mono block Pump as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 30,194.7 | |
| — | 3.00 | — | — | ||
| L.T. Panel-I Manufacturing, supplying, testing and commissioning of wall/floor mounted (as per site requirement) LT Distribution board with 01 No. 200 Amp. 4 pole 415 Volt, 50 Hz, thermal magnetic MCCB as incoming and 02 No.100 Amp. 4 pole MCCB, 03 Nos. 40 Amp. 4 pole MCCB as outgoing. .(As per Specification attached) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,65,049.84 | |
| — | 20.00 | — | — | ||
| Supply fabrication, erection, testing and commissioning of G.I. octagonal pole 5 mtrs. long double arm suitable for street light fixture, 2 x36/70w including digging of pit, making foundation and muffing with cement, concrete 1:2:6. As per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,95,704.8 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing and commissioning of call bell220/230V as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 9,342.8 | |
| — | 74.00 | — | — | ||
| Supply, install, test & commission of Ray roll plug socket 20amp SPN Ray Roll Plug socket including connection /wiring of "C" series 32 amps SP-MCB as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 66,295.86 | |
| — | 220.00 | — | — | ||
| Cable duct A45(H)x45(W) along with duct cover A45 in length of 1mtr standard slot make- L&T, PHONIEX or similar. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 28,036.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1TO12newCOMPRESSED.pdf ACS01to12of GCC2022
ATTACHMENT
SOR19Rof2026-27.pdf
ATTACHMENT
TD19Rof26-27.pdf
ATTACHMENT
ACS1TO12newCOMPRESSED.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .