Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹4.1 L+₹80,835 (24.4%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹4.2 L+₹86,500 (26.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹4.8 L+₹1.5 L (45.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹5.5 L
EMD Value
₹11,000
Closing Date
12 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur - 342011 (Raj)
PETTY REPAIR AND DAY TO DAY MAINTENANCE OF E AND M WORKS IN ZONE-B AND ZONE-C AT DEFENCE LAB JODHPUR
2022_MES_531898_1
8483/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹11,000
Yes
23 Jan 2023
18 Jun 2022
14 Jul 2022
18 Jun 2022
12 Jul 2022
28 Jun 2022
20 Jun 2022 - 27 Jun 2022
60 days
Amount
S&F in repairs Modular Switch one way 6A,1 module combined complete all as specified and directed by engineer in charge. NOTE :-(Applicable to All Items Sr No:-01 to 38 ) (i) Contractor or his/her representative will report to E/M complaint cell with 01 Electrician and 01 Helper along with T&P to receive complaints in the morning 0900 hrs with necassary daily stores as requested to attend day to day complaints (ii) The complaints should be attended & completed within 72 Hrs after receiving the complaint slip failing which a penality of Rs 500 /-will be recovered for each complaint from the contractor payment (iii) The cost of Electrician (Skilled ) & Helper(Semiskilled ) should be deemed to be included in the item rates quoted by the contractor,nothing will be paid extra for hiring the skilled labour (iv) The contract can be made operational for 09 months irrespective of qty provided in BOQ (v) The contractor shall note that the electrician and the helper should have their individual bycycle/vehicle to attend the complaints (vi) The contractor shall note that electrician and helper employed should have basic/keypad mobile with them for the easy communication with E/M complaint cell/user/JE/Engr-in-charge.
S&F in repairs Modular Switch one way 16A,1 module combined complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular Socket 6A 2/3 pin combined 2 module complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular Socket 6/16A 2/3 pin combined 2 module complete all as specified and directed by engineer-in-charge.
M&L modular switch socket outlet 3 pin 6 amp flush type complete all as specified and directed by engineer-in-charge.
M&L modular switch socket outlet 3 pin 16 amp flush type complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular white cover plate with frame 2 module complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular white cover plate with frame 3 module complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular white cover plate with frame 4 module complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular white cover plate with frame 6 module complete all as specified and directed by engineer-in-charge.
S&F in repairs Modular white cover plate (Vertical/Horizontal) with frame 8 module complete all as specified and directed by engineer-in-charge.
S&F in repairs MCB SP ‘C’ curve, 10KA 6 to 32 amps including necessary connection complete all as specified and directed by engineer-in-charge.
S&F in repairs MCB SP ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed by engineer-in-charge.
S&F in repairs MCB SPN ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed by engineer-in-charge.
S&F in repairs MCB TP ‘C’ curve, 10KA 25 to 63 amps including necessary connection complete all as specified and directed by engineer-in-charge.
S&F in repairs MCCB Thermal magnetic protection type, 16KA, 125 amps,3 pole including necessary connection complete all as specified and directed by engineer-in-charge.
S&F in repairs Ceiling rose, 3 phase / PVC / Polycarbonate, isolated body complete all as specified and directed by engineer-in-charge.
S&F in repairs 3 pin,6 Amps plug top, 230 V AC complete all as specified and directed by engineer-in-charge.
S&F in repairs 3 pin,16 Amps plug top, 230 V AC complete all as specified and directed by engineer-in-charge.
S&F in repairs Single pole enclosure with two pin and earth plug and socket with one single pole MCB 20 Amps complete all as specified and directed by engineer-in-charge.
S&F in repairs Factory made DB SPN 8 way double door with 200 Amps rated bus bar concealed in wall IP 43 protection for fixing MCB complete all as specified and directed by engineer-in-charge.
S&F in repairs Factory made DB TPN 12 way double door with 200 Amps rated bus bar concealed in wall IP 43 protection for fixing MCB including taking down old unserviceable DB of any type complete all as specified and directed by engineer-in-charge.
Supply and fix in repairs Vertical TP&N MCCB 125A Distribution Board 8 way double door with provision for (MCB/Isolator/RCB) ,IP:43 protection,isolated Neutral bar,door earthing,suitable for MCCB's upto 125A as I/C, complete with insulated bus bar arrangement complete all as specified and directed by engineer-in-charge.
Supply and fix 2.50 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable for connections including taking down old unserviceable connections complete all as specified and directed by engineer-in-charge. Note:- Each wire shall be measured.
Supply and fix 4.0 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable for connections including taking down old unserviceable connections complete all as specified and directed by engineer-in-charge. Note:- Each wire shall be measured.
M&L for fixing PVC white rectangular/pipe casing capping of 20/25 mm bore/width size complete all as specified and directed by engineer-in-charge.
Taking down Ceiling fan/exhuast fan, sealing cable end dismantling blades and removing fan and blades to store for refixing complete all as specified and directed by engineer-in-charge.
M&L for repair of Ceiling fan 1200/1400 mm sweep of any make obtained from above item, rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
M&L for repair of Exhaust fan of any sweep of any make obtained from taking down, rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
Supply and fix in repairs suitable Step type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by engineer-in-charge.
S&F in repairs capacitor 2.5 MFD suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and directed by Engineer-in-charge.
S&F in repairs capacitor 4 MFD suitable for ceiling fan / exhaust fan / wall mountaining fan/desert cooler of any sweep complete all as specified and directed by Engineer-in-charge.
S&F in repairs Batten holder ISI marked complete all as specified and directed by engineer-in-charge.
S&F in replacement LED bulb of 9watt,6500K complete all as specified and directed by engineer-in-charge.
S&F in repairs 8/12 watts Round/Square shaped surface/wall mounted LED flat panel PDC aluminium housing and PMMA diffuser,robust type, complete all as specified and directed by engineer in charge. Make Bajaj/CG/Havell/philips.
Supply and fixing in replacement LED lumanaire 600mm X600 mm 35/36 watt 220 V AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver ,holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-charge. Make Bajaj/CG/Havell/philips.
S&F in repairs radiance ray plus LED batten for home 2400 lumens cool day light 24 watt ,operating voltages:140-270 volts environmentalfriendly,energy efficient ready to use pack complete all as specified and directed by Engineer-in-charge. (Crompton cat part No:LDRR24-CDL or equivalent make as approved by AGE(I) R&D Jodhpur)
S&F in replacement of LED Tube light rod 20 watt complete all as specified and directed by engineer-in-charge. .(Crompton cat part No:LED20TLCDL or equivalent make as approved by AGE(I) R&D Jodhpur)
M/s B. S. Solanki Builders
vinayandsons
SHRI BHIKSHU ART AND CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .