Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
23 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, JIPMER Puducherry
The Director, JIPMER Puducherry
Construction of Path Way Shed at SOPD, JIPMER Campus, Puducherry
2025_JIPMP_888807_1
No. JIPMER/ED/WORKS/05/2025
Open Tender
Miscellaneous Services
Works
60 days
The Director, JIPMER Puducherry
As per Tender Document
5 documents required · 5 mandatory
₹590
Payable To The Director, JIPMER
₹38,000
Yes
22 Dec 2025
8 Dec 2025
24 Dec 2025
8 Dec 2025
23 Dec 2025
9 Dec 2025
8 Dec 2025 - 8 Dec 2025
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
CEMENT CONCRET (CAST IN SITU) Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Applying priming coat: : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer with enamel paint all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Supplying and fixing of 10mm thick multiwall Bronze colour with UV protection treatment trade code name Lexan Bronze LMB 10/2RS 1.7 of SABIC PLASTICS sheet weight not less than 1700 gm/Sqm light transmission of 65% b) The masking carrying instruction as to which side UV protection and the shade should be installed facing outwards c) Fire retardant confirming to IS 14443-1987 d) Aluminium leak proof fixing management system membrane system minimun 50micron powder coated with approved colour, confirming IS 733-1987 Alloy 606373 EPDM rubber gaskets, Silicone sealent, cold forged fasterns to be used for fixing the polycarbonate shee
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 A Double Pole
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size 20 mm
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole 10 A ,30mA
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) withDriver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°Kcomplete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output . . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.heat sink of aluminium housing Powder coated die cast /Extruded aluminiumBody lm/Watt).20 Watts 2 FEET
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm
Supplying and fixing Double Pole sheet steel enclosure on surface/ recess DP MCB complete with connections, testing and commissioning etc. as required.
Design of shed work inluding architectural and structural drawing as directed by the Engineer-in-charge.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.49 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_934193.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .