Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | ₹34.1 L Quoted ₹35.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹41.1 L+₹6.2 L (17.7%)Rejected-AOC PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | ₹41.1 L+₹6.2 L (17.7%) | L2 | Rejected-AOC L2 |
| 3 | L3₹43.9 L+₹8.9 L (25.5%)Rejected-AOC | ₹43.9 L+₹8.9 L (25.5%) | L3 | Rejected-AOC L3 |
| 4 | L4₹49.8 L+₹14.8 L (42.4%)Rejected-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | ₹49.8 L+₹14.8 L (42.4%) | L4 | Rejected-AOC L4 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
5 Dec 2022, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
CERTAIN SANCTION E/M WORKS UNDER AGE EM NO I AND AGE EM NO II
2022_MES_561211_1
8986/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹88,000
Yes
9 Jan 2023
3 Nov 2022
7 Dec 2022
3 Nov 2022
5 Dec 2022
22 Nov 2022
3 Nov 2022 - 21 Nov 2022
Amount
Supply & Fix in replacement of Decorative LED 25 watt Post Top fixture , base cap, glass diffuser, black colour, having IP43 protection, 1.6 metre long, die cast aluminium pole complete with base plate and GI foundation bolts and nuts including earth work and PCC foundation and taking down old post top lights compete all as specified and directed by Engineer-in-Charge
Supply & Fix in replacement of Post Top lamp LED 40 watt with moonlight effect and efficient light distribution, having rated IP65 protection with 3 metre long GI pole complete with base plate and GI foundation bolts and nuts including earth work , PCC foundation and taking down old post top lights compete all as specified and directed by Engineer-in-Charge
Supply & Fix in replacement Post Top lamp with decorative LED 25 watt fixture , glass diffuser, black colour, having IP43 protection, aluminium die casting without pole complete with base plate, bolts and nuts including taking down old post top lights compete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement of Decorative Bollard LED 25 Watt light, having IP-54 protection, 0.8metre long, die cast aluminium housing , opal white PC diffuser in built LED complete with base plate and GI foundation bolts and nuts including earth work , PCC foundation and taking down old post top lights compete all as specified and directed by Engineer-in-Charge
Supply and Laying UG cable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 2 core 10 Sqmm in trenches /duct/floor/wall with provision of saddle and lugs, joints etc including connection and taking down old cable complete all as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth and getting out in soft/loose soil for laying of cable all as specified and directed by the Engineer-in-Charge
Material and labour for sand cushioning for underground cables complete all as specified and as directed by the Engineer-in-Charge. (Note: Punned thickness shall be measured & paid for the Measurement purpose)
Material and labour for common burnt clay building bricks sub-class 'B' designation of size 230X115X75mm complete all as specified and directed
Returning, filling of soil including spreading leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by the Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and directed by the Engineer-in-Charge
Material & Labour for GI tubing medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc, of size 40mm dia including taking down old unserviceable tubing complete all as specified and directed.
Supply & Fixing wiring with two run of PVC (FR) insulated multistranded copper conductor cable of 1.5 Sqmm drawing through PVC conduits with continuous earth wire PVC (FR) insulated cable of size 1.5 Sqmm connected to earth including all conduit accessories complete all as specified and directed. (Note: Two run of sub main wire, one run of earth wire and one run of PVC Conduit pipe measured as one unit).
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 100 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix junction box made of glass fibre reinforced and transparent poly carbonate of size 126x 228x 111mm, KVPC8104 with IP 66 protection including cable connector with MCB 6Amps SPN and suitable size clamps fixing for pole/in PCC foundation including taking down old unserviceable fitting complete all as specified and directed
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 150 Sqmm with suitable cable gland including taking down of old unserviceable cable complete all as specified and directed.
Ditto All as per Sl Item No 15 , But aluminium conductor of size 3.5 core 120 Sqmm
Ditto All as per Sl Item No 15 , But aluminium conductor of size 3.5 core 95 Sqmm
Ditto All as per Sl Item No 15 , But aluminium conductor of size 3.5 core 70 Sqmm
Ditto All as per Sl Item No 15 , But aluminium conductor of size 3.5 core 50 Sqmm
Ditto All as per Sl Item No 15 , But aluminium conductor of size 3.5 core 25 Sqmm
Material & Labour for GI tubing medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc, of size 80mm dia including taking down old unserviceable tubing complete all as specified and directed.
Supply & install, testing and commissioning in replacement of outdoor type LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm x 40mm x 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 600 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm x 750mmx 500mm, mounted on angle iron stand made out of size 40mm x 40mm x 6mm grouted of digital volt meter & Amps meter with CTs including taking down of old existing panel and comprising the following items complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 600 Amps aluminium strip - 1 Set (b) MCCB 400 Amp 35 KA 4 pole - 01 No (Incoming) (c) MCCB 250 Amp 35 KA 4 pole - 01 No (Outgoing) (d) MCCB 160 Amp 25 KA 4 pole - 03 Nos (Outgoing) (e) On load change over switch 400 A, 4 Pole (for by pass) (f) Volt meter digital 0-500 volt - 01 No (g) Amp meter digital 0-300 Amp - 01 No (h) Indicator lamp Yellow, Red, Blue - 01 Set.
Supply & install, testing and commissioning in replacement of outdoor type LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm x 40mm x 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm x 750mmx 500mm, mounted on angle iron stand made out of size 40mm x 40mm x 6mm grouted of digital volt meter & Amps meter with CTs including taking down of old existing panel and comprising the following items complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 400 Amps aluminium strip - 1 Set (b) MCCB 250 Amp 35 KA 4 pole - 01 No (Incoming) (c) MCCB 200 Amp 35 KA 4 pole - 01 No (Outgoing) (d) MCCB 160 Amp 25 KA 4 pole - 04 Nos (Outgoing) (e) Volt meter digital 0-500 volt - 01 No (f) Amp meter digital 0-300 Amp - 01 No (g) Indicator lamp Yellow, Red, Blue - 01 Set.
Material & Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metre below ground level) with top edge of earth plate not less than 1.5 Metre below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering funnel with 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point or LT panel etc, and testing on completion, complete all as specified & directed by Engineer-in-Charge.
Material & Labour for straight through joint 3.5 core 70 to 150 Sqmm with all accessories.
Material & Labour for straight through joint 3.5 core 25 to 50 Sqmm with all accessories.
Demolition of Brickwork built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for Precast cement concrete solid block type B1 1:3:6 (using 20mm graded stone aggregate) exceeding 10cm in width and setting in cement mortar 1:6 complete all as specified.
Demolition of un reinforced cement concrete in ground floors and paving not exceeding 15cm thick (below or above ground level) complete all as specified.
Material & Labour for 100mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in sub base including formwork complete all as specified.
Material & Labour for 75mm thick PCC 1:3:6 type C2 (using 20mm graded aggregate) as in plinth protection complete all as specified
Dismantling floor hearth or wall tiling including cement mortar bedding complete all as specified
Material & Labour for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in flooring including finishing cement concrete rough surface without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Non-skid ceramic coloured tiles 6 to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match (joint free non skid tiles) with and including screed bed or bedding layers of mortar 20mm thick for laying floor finishes in CM 1:4 complete all as specified and directed
Material & Labour for Glazed ceramic colouerd tiles in vertical surface of size 350x250x7mm/450x350x7mm set and jointed in neat cement slurry and pointed in white or colour cement to match with and including back coat of 10mm thick on fair faces of brick work in CM 1:4 on walls complete all as specified and directed
Taking down old unserviceable GI tubing of size 25mm complete all as directed by Engineer-in-Charge.
Supply and laying CPVC 25mm outer dia SDR-13.5 pipes & plain CPVC SDR 11 fittings brass threaded fittings in trenches complete all as specified.
Material & labour for fixing the fountain brass nozzles in a distance of 20cm using 25mm CPVC pipes SDR 13.5 & plain CPVC SDR 11 fittings and brass female threaded Tee 25 x 15mm on wall/floor with complete arrangement all as directed by Engineer In Charge. (Note:- Cost of Nozzles will measured and paid separately)
Supply only 20 feet brass fountain nozzle, 12 Bar, 5mm complete all as specified and directed.
Supply and fixing 25mm bore CPVC Ball valves suitable for CPVC pipe with necessary fittings ,including taking down old one complete all as specified and directed.
Supply and fixing of monoblock pump set suitable for 230V SPN system having capacity 1HP, head range of 6 to 48 metre & discharge range of 4280 - 700 LPH including starter wiring conduit etc, having 25mm x 25mm cross section with and including PCC staging complete all as specified.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
M/s Antony Kallarakkal
P N Enterprises
M/s.Rejoy Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .