| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 CrAccepted-AOC | ₹9.6 Cr Quoted ₹9.7 Cr | L1 | Accepted-AOC Being L1 Bidders |
| 2 | L2₹10.3 Cr+₹58 L (6.00%)Rejected-Finance | ₹10.3 Cr+₹58 L (6.00%) | L2 | Rejected-Finance Not found lowest |
| 3 | L3₹11.9 Cr+₹2.2 Cr (22.8%)Rejected-Finance | ₹11.9 Cr+₹2.2 Cr (22.8%) | L3 | Rejected-Finance Not found lowest |
Tender Value
₹8.6 Cr
EMD Value
₹5 L
Closing Date
23 Mar 2019, 11:00 amClosed
Executive Engineer
Irrigation and Public Health Division Paonta Sahib
Providing Installation and commissioning of 1.72 MLD STP for Zone III based on SBR Technology including ancillary works and Operation Maintenance of 180 months 15 Years after stablisation of plant at Jambu ka Khalla Kishanpura
2019_HPIPH_28330_1
20619-718 dated 05.03.2019
Open Tender
Civil Works
Item Wise
5840 days
Paonta Sahib at Jambu Ka Khalla
Please refer to tender documents
8 documents required · 8 mandatory
₹2,500
Yes
EE IPH Division Paonta Sahib
₹5 L
Yes
1 Jan 2020
8 Mar 2019
23 Mar 2019
8 Mar 2019
23 Mar 2019
8 Mar 2019
8 Mar 2019 - 23 Mar 2019
Amount
Sewerage Treatment Plant
Construction of Sewerage Treatment Plant of 1.72 MLD capacity based on Sequencing Batch Reactor (S.B.R.) technology including evolving of hydraulic & structural design & drawings, planning, testing and commissioning followed by Tertiary Treatment by constructing wet land, multimedia filter, auto chlorination as per the provisions of Manual on Sewerage & Sewage Treatment published by CPHEEO Manual (Latest edition). The Sewage Treatment plant should be capable of treating domestic raw sewage having characteristics of BOD =375 mg/litre & SS =750 mg/litre and the characteristics of treated /disposable effluent should comply with the standards as per the norms i.e. PH = 6.5 - 9.0 day BOD ≤ 10 mg/litre, COD ≤ 50 mg/litre, SS < 20 mg /litre NH 4 - N ≤ 5 mg/litre, N - Total ≤ 10 mg/litre, Fecal Coli form (MPN /100 ml) <100. The scope of work including C/O inlet chamber, 2 Nos. Screen channel with cleaning arrangement, 2 Nos. Grit channels, Partial flume, CCT, coarse and fine bar screen, sewage collection, 2 Nos. reactors with Sequencing Batch Reactor ( S.B.R.) technology of required capacity installed therein, alum dosing tank with required arrangement, polyectrolyte solution tank, Sludge recycle system with pumping arrangement, Sludge dewatering system (Mechanical Dewatering) comprising of sludge sump, filter press and filter press house, by pass arrangement for all units, walkways, Boundary wall, street lights, gate, SITC of electromechanical for sewage treatment plane , DG set ,Plant building including laboratory of required class as per CPHEEO manual of Sewerage and Sewage treatment, Lab equipments & furniture, chlorine contact chamber with solution tank and solution dozer constant head- type, providing and installation of all mechanical & electrical equipments including site development all kinds of soil complete in all respect and as per term and conditions of NMCG.
OPERATION & MAINTENANCE.
Repair & Maintenance of STP to Operate repair & Maintenance all civil works and electromechanical equipment in sewerage treatment plant of 1.72 MLD capacity for 15 years including disposal of dry sludge complete in all respect to the entire satisfaction of the Engineer-in-charge, firm shall comply the stringent effluent as per latest norms/ standard and as per terms and conditions of NMCS.
JM ENVIRO TECHNOLOGIES PVT. LTD.
aparna construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .