Executive Engineer, Electric (R&B) Division, Rajkot
Providing and Erecting LED Street Light on State Highway & Major District Road (MDR) of Rajkot District.
315362
04 of 2026-27
Open
Electrical Works
Rajkot
7 documents required · 7 mandatory
₹900
Executive Engineer, Electric (R&B) Division, Rajkot.
₹20,800
18 Jun 2026
18 Jun 2026
18 Jun 2026
2 Jul 2026
18 Jun 2026
Name of work: Providing and Erecting LED Street Light On State Highway & Major District Road ( MDR ) of Rajkot District
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Supplying and erecting Flexible PVC insulated multi strand
multi core 1.1 kv grade ISI marked copper wires of following
size to be erected as directed.(e) 1.50 Sq.mm 3 core round
providing and erecting Miniature circuit breaker single pole
0.5A to 2A system and having breaking capacity 10 KA to be
2 107 Ea erected in existing box. confirming to IS 8828/1996 with ISI 270.68
Providing & erecting 415V MCB Four Pole Switch for
Lighting Load (B curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity
(b)40 Amp. Cat.III
Providing and erecting HOT deep Galvanised iron strip wire
Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
3 Ea Length of pipe - 1 Mtr 4591.46
Back filling compound - 1 Nos Bag of 15 Kg.
Providing and erecting Pipe type earthing having 150 cms.long
and 2.5 cms. dia. galvanised iron pipe with coupling and buch
buried in specially prepared earth pit complete with necessary
SWG earth wire.
For using salt and charcoal / coke as required for pipe type
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be laid
8 75 Mtr on wall with necessary clamps or in existing trench / pipe of 183.82
following size of cables (A) 3 1/2 core 25 Sq. mm ( 16 Sq.
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
cable multistrand / Solid Aluminium conductor for 1.1 KV. to
9 1680 Mtr be laid on wall with necessary clamps or in existing trench / 140.39
pipe of following size of cables (C) 4 core 10 Sq. mm
Making trench in soft soil of suitable width of 90 cm deep for
laying cable or locating the fault all over the run and back
filling the same and making the surface as normal ground.
Making trench in Hard Murrum / Tar Road of suitable width of
90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same and
making the surface as normal ground.
(B) If additional machinery like hammer driller or JCB use
Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
cables.(C) 2 to 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass double
compression type cable gland with rubber ring for PVC
13 6 Ea insulated armoured cable complete with out going tails, 66.66
insulating tape etc for following size of cables.(A) 3 & 1/2 /
Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
14 260 Ea pressure tool & connected to switchgear terminals with 13.13
brass/cadmium plated nut bolts in an approved manner. (B)
Solder less crimping type Copper lugs conforming to IS
suitable for cable of following size evenly crimped with high
15 12 Ea pressure tool & connected to switchgear terminals with 12.12
brass/cadmium plated nut bolts in an approved manner. (C)
Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia
Supplying and erecting approved make Octagonal pole made
from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
17 65 Ea MCB Mounting, stud type terminal and arrangement for cable 11411.99
termination to be erected With Suitable foundation (Included)
as per details given by manufacturer considering site
requirement.(E) 7 Mtr. Long 70 mm Top X 135 mm bottom
dia, 3 mm thickness with 225mmX225mmX16mm base plate,
4-M20 Bolts and 600mm long with necessary G.I. J Bolts
.Approx Pole weight 67 kg
Providing and erecting street light pole bracket comprising
main B Class GI pipe of 4.2 cm/require outside dia. complete
with suitable B Class G.I sleeve tubing of approx.
45cms.length and suitable for 76.5 mm / 80mm. / require size
pole top having sufficient fasteners for fixing the brackets and
18 42 Ea having spread of 1 mtr. length with suitable rise as per site 829.21
condition & suitable welded stiffener reducer and nipple with
check nut complete painted with one coat of Red oxide / PU
base primer and two coats of Aluminium / PU paint. paint with
following nos of arms.[B] Double Arm Bracket 1 Mtr
23 Ea [A] Single Arm bracket 1 Mtr 614.08
Supplying & erecting approved make Digital time switch
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts
19 3 Ea Minimum switching setup time 1 minimum & LCD display. 3168.37
Also comprised permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary connection
erected as directed.
Supplying & erecting power contactor ,AC3 duty for time
20 3 Ea switch complete erected as per direction Cat III (D) 4 pole 2782.55
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
21 embossed 160 to 270 V,Power Factor more than 0.95, THD < 0.00
10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
(A) Street Light (IP-65), Surge protection -4KV integral and
107 Ea ,Light must have 440VAC line supply with over-voltage 5976.17
protection. (iii) Above 60 to 90 watts Cat-lll
Supplying & erecting IP 55 grade following size section pillar
fabricated from joint less M.S. Sheet with angle iron legs made
from jointless M.S. Angle with cable clamps to be buried in
ground to have appropriate erection to work uniform until
erected with cement concrete foundation and 45 cm high bricks
work finishing with plaster etc. hinged double door internally
supported on both side, with internal and outside looking
arrangement with look and keys in duplicate 35 x 35 x 5 mm
M.S. Angle of Two Nos. one is welded and other with nut and
bolt for erecting Bakelite sheet. Painting the Section Pillar
inside and out side with three tank powder coated paint.
section pillar roof should be without joint with water leakage
proof & tested as per IP 55 test & followed by IS 2147 of
(B) 75 X 60 X 45 cm section pillar fabricated from 16 Gauge
3 Ea MS Sheet with angle iron legs 45 cm long made from 35 X 35 3595.60
X 5 mm thick MS angle.
Supplying KITKAT pattern porcelain cut-out fuse with base of
23 9 Ea following current capacity erected on existing block board.(v) 278.76
Supplying and erecting HYLAM sheet on existing angle iron
frame.for following thickness (C) 6mm
providing and erecting Mains with ISI marked, 1.5KV grade
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected
25 24 Mtr in existing pipe of following size (Specifically for control 142.41
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
required. (g) One wire 16.00 sq. mm
Note:- The Credit of dismentalled materials for Rs.00.00 shall be recovered from the First R.A. bill payable to the contrator and
there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount of
my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation
regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other
tender documents of this work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of
Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote
the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-in-
Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the
agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) RJT.pdf
SCH-B.pdf
MAKE list RJT.pdf
SBD.docx
DOCX
SPECIAL CONDITION RJT.pdf
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid