Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-Finance | ₹4.9 Cr | L1 | Accepted-Finance 1st Lowest |
| 2 | L2₹6.5 CrRejected-Finance | ₹6.5 Cr | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹7.0 CrRejected-Finance | ₹7.0 Cr | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | M/S SAHA AND MAITRA CO L1 | HANNAN BUILDERS PRIVATE LIMITED L2 | M.C.GHOSH AND ASSOCIATES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Geo-Technical investigation, Design & drawing & Construction of Clear Water Reservoir of capacity 450 cum with 100 sqm Pump House including all Electro-Mechanical works ) Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect. (Details as per scope of work mentioned in eNIT.) | 1 | Job | 2,28,83,625 ₹2,28,83,625 | 3,00,00,000 ₹3,00,00,000 | 1,50,00,000 ₹1,50,00,000 |
| 2.00Geo-Technical investigation, Design & drawing (Sub-structure part) & Construction of RCC Elevated Over Head Reservoir (Intze type) of capacity 450 cum of staging height 20 meter with pile foundation including pipe connection for head works, Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect at Zone-IV ward-13 in kandi Municipality. (Details as per scope of work mentioned in eNIT.) | ||||||
| 2.01 | Geo-Technical investigation, Detailed Design and drawing & Construction of Pile foundation (Minimum Grade M25 including cost of reinforcement works as per approved drawing) & direction of EIC including construction of Pile cap & Performing Vertical load test on single Pile (1 no) in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the Testing load up to 100 T, . | 1 | Job | 85,00,000 ₹85,00,000 | 1,10,00,000 ₹1,10,00,000 | 75,00,000 ₹75,00,000 |
| 2.02 | Construction & commissiong of Super structure of OHR along with other ancilliary works ; Internal ilumination & yard lighting site clearance etc. complete in all respect as per departmental drawing , specification & direction of EIC | 1 | Job | 81,00,000 ₹81,00,000 | 1,05,00,000 ₹1,05,00,000 | 1,25,00,000 ₹1,25,00,000 |
| 3.00Construction of boundary wall over retaining wall, land development, Drain and approach Road complete in all respect as per departmental drawing , specification & direction of EIC | ||||||
| 3.01 | Boundary wall over Retaining wall | 175 | m | 22,860 ₹40,00,500 | 30,000 ₹52,50,000 | 1,00,000 ₹1,75,00,000 |
| 3.02 | Land development. | 1,655 | sqm | 825 ₹13,65,375 | 1,300 ₹21,51,500 | 5,000 ₹82,75,000 |
| 3.03 | Construction of drain | 65 | m | 7,700 ₹5,00,500 | 10,000 ₹6,50,000 | 30,000 ₹19,50,000 |
| 3.04 | Approach Road | 175 | m | 10,000 ₹17,50,000 | 13,000 ₹22,75,000 | 20,000 ₹35,00,000 |
| 4.00 | CWR with Pump House & Sub-Station : With 3 (three) months trial run and necessary training of maintenance staff & thereafter (subsequently) 5 (five) years operation and maintenance with guarding arrangement (As detailed in the Scope of Work of eNIT) | 1 | Job | 20,00,000 ₹20,00,000 | 30,00,000 ₹30,00,000 | 40,00,000 ₹40,00,000 |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
15 Jun 2026, 12:00 pmClosed
Superintending Engineer
poura Prasashan Bhavan,1st Floor,DD-1,Sector-1,Salt Lake,Kolkata-700064
Implementation of augmentation and strengthening of water supply scheme within Kandi Municipality under AMRUT 2.0 which includes Construction of one no 450 cum OHR with Geotechnical ...in all respect, commissioning, trial run and O and M for 5 Year
2026_MAD_5014282_1
WBMAD/eNIT-01 of SE(E)/2026-27
Open Tender
CIVIL WORKS
400 days
Kandi Municipality
Please refer Tender Documents
4 documents required · 4 mandatory
₹0
₹5 L
Yes
O/O the Superintending Engineer
30 Jun 2026
21 May 2026
17 Jun 2026
21 May 2026
15 Jun 2026
22 May 2026
1 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Geo-Technical investigation, Design & drawing & Construction of Clear Water Reservoir of capacity 450 cum with 100 sqm Pump House including all Electro-Mechanical works ) Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect. (Details as per scope of work mentioned in eNIT.) | 1 | Job | - | - |
| 2Geo-Technical investigation, Design & drawing (Sub-structure part) & Construction of RCC Elevated Over Head Reservoir (Intze type) of capacity 450 cum of staging height 20 meter with pile foundation including pipe connection for head works, Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect at Zone-IV ward-13 in kandi Municipality. (Details as per scope of work mentioned in eNIT.) | |||||
| 2.01 | Geo-Technical investigation, Detailed Design and drawing & Construction of Pile foundation (Minimum Grade M25 including cost of reinforcement works as per approved drawing) & direction of EIC including construction of Pile cap & Performing Vertical load test on single Pile (1 no) in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the Testing load up to 100 T, . | 1 | Job | - | - |
| 2.02 | Construction & commissiong of Super structure of OHR along with other ancilliary works ; Internal ilumination & yard lighting site clearance etc. complete in all respect as per departmental drawing , specification & direction of EIC | 1 | Job | - | - |
| 3Construction of boundary wall over retaining wall, land development, Drain and approach Road complete in all respect as per departmental drawing , specification & direction of EIC | |||||
| 3.01 | Boundary wall over Retaining wall | 175 | m | - | - |
| 3.02 | Land development. | 1,655 | sqm | - | - |
| 3.03 | Construction of drain | 65 | m | - | - |
| 3.04 | Approach Road | 175 | m | - | - |
| 4 | CWR with Pump House & Sub-Station : With 3 (three) months trial run and necessary training of maintenance staff & thereafter (subsequently) 5 (five) years operation and maintenance with guarding arrangement (As detailed in the Scope of Work of eNIT) | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
Tendernotice_2.pdf
PDF • 0.60 MB
Drawing.pdf
Other Document • 1.57 MB
BOQ_5082329.xls
BOQ • 0.31 MB
Corrigendum.pdf
PDF • 0.15 MB
Download all tender documents and submit your bid