Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | ₹34.8 L Quoted ₹35.8 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹39.8 L+₹4.0 L (11.1%)Rejected-Finance 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | ₹39.8 L+₹4.0 L (11.1%) | L2 | Rejected-Finance Not being lowest tenderer |
| 3 | L3₹41.4 L+₹5.6 L (15.6%)Rejected-Finance | ₹41.4 L+₹5.6 L (15.6%) | L3 | Rejected-Finance Not being lowest tenderer |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected being no remark in WLR |
Tender Value
₹46.6 L
EMD Value
₹93,220
Closing Date
29 May 2024, 6:00 pmClosed
GE RANIKHET
GE (MES) RANIKHET
SPECIAL REPAIR TO ANNEXE OF NEW HANGAR MET OBSERVATORY AND ITS ANCILLARIES SPECIAL REPAIR TO BUILDING NO T 222 OTM ACCN AND SPECIAL REPAIR TO BUILDING NO T 42 OR TOILET AND BATHROOM AT MIL STN HALDWANI UNDER GE RANIKHET
2024_MES_651730_1
GE/RKT/18 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
Haldwani under GE Ranikhet
As per NIT
6 documents required · 6 mandatory
₹500
GE RANIKHET
₹93,220
Yes
31 Aug 2024
30 Apr 2024
5 Jun 2024
30 Apr 2024
29 May 2024
15 May 2024
Amount
Demolition of brick work or stone masonry/ precast PCC block walling built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' old size bricks using old size bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or PCC blocks or stone wall or concrete surface etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick work/ concrete surfaces fair and even complete all as specified and directed.
M&L 15 mm thick cement plaster on fair faces of brick work or concrete surface on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces on wall surfaces and two coat of oil emulsion distemper, white or tinted over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of chalk whiting complete all as specified and directed.
M&L for preparation washing, rubbing down and stopping of distempered and painted surfaces of old surfaces of wall and applying two coats of cement base paint over a coat of chalk whiting complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for RCC type B1 1:2:4 using 20 mm graded stone aggregate, slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for precast cement concrete type B1 1:2:4 (Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainage cover set in cement mortar 1:6 including necessary formwork complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with ms wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in level course with finishing in cement concrete surface even and rough to receive screed bed complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops rounded or chamfered on edges complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone agg) as in plinth protection laid to slope in bays and finishing the surfaces of concrete topping fair and even complete all as specified and directed.
M&L for joint free non - skid coloured ceramic tiles 7 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over with and including screed bed of 15 mm thick in CM 1:6 and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L glazed coloured ceramic tiles in vertical surface 450 x 300 x 7-8mm thickness and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 on fair face of brick work or concrete surfaces complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections by disconnecting fittings/ tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections by disconnecting fittings/ tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 25mm dia steel tubing and connections by disconnecting fittings/ tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
M&L for 15mm bore GI tubing, medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
M&L for 20 mm bore GI tubing, medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
M&L for 25 mm bore GI tubing, medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair 15mm bore dia bib tap long body CP, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15mm bore dia fancy type, chromium plated angle cock, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with 225 mm Flange, swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair 15mm bore dia fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and directed.
S&F PVC connections 15mm size with PTMT Nuts of length 600mm and fixed complete all as specified and directed.
S&F in repair tubular towel rail CP brass, chromium plated D type with CP Brackets, 600 mm long between flanges complete all as specified and directed.
S&F glass shelf 450 x 125 x 6MM (with ABS bracket chromium plated bracket guard and SS railing complete all as specified and directed.
S&F in repair soap dish stainless steel complete all as specified & directed.
S&F in repair peg set of 6 stainless steel complete all as specified and directed.
S&F in repair hand shower (health faucet) CP Brass 15 mm bore with 1 meter long easy flex tube in chrome finish and wall hook complete all as specified and directed.
S&F in repair vitreous china squatting pan, Orissa pattern including CI spun trap, size 580 x 440 mm white, with integral foot rests squat pattern closet also includes setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggregate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing (thickness as indicated) and making good floor including cutting to the flush pipe and necessary repair to the floor, including 110mm VC (SWR) 'P’ trap complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white/coloured (including fixing bolts & flush pipe, plastic water closet seat, black, closed pattern with bottom, and cover and mild steel chromium plated or aluminised hinging device etc.) complete all as specified and directed.
S&F in repair PVC flushing cistern 10 litre capacity, low level valve less, symphonic action type, white, with inlet, ball valve, float and handle including 32mm dia pvc flush pipe, a pair of ms brackets, cp flush bend including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable flushing cistern and connected items of any description complete all as specified and directed.
S&F in repair vitreous china wash basin, white, flat back, size 450mm x 300mm, including brackets, PVC waste pipe 32mm dia, waste coupling brass, chromium plated and including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
Dismantling of CI /AC pipe 100mm dia jointed in cement mortar and taking out of trench if required complete all as specified and directed.
M&L for cast iron spun pipe 100mm dia for soil, waste or vent pipe in any lengths with or without ears, jointed with and including cement joints fixed to walls including necessary clamps etc., but except pipes complete all as specified and directed.
Dismantling of CI/ AC pipe 75mm dia or less jointed in cement mortar and taking out of trench if required complete all as specified and directed.
M&L for cast iron spun pipe 75mm dia for soil, waste or vent pipe in any lengths with or without ears, jointed with and including cement joints fixed to walls including necessary clamps etc., but except pipes complete all as specified and directed.
S&F 110 mm bore PVC (SWR) soil, waste and vent pipes single socketed including necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortar 1:3 or with PCC 1:2:4 complete all as specified and directed.
Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F solid PVC door frame of size 50x47mm made of 5mm plain colour PVC sheet reinforced with MS square tube S&F complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F aluminium handle, cast type anodized 150mm size complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S&F butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed.
S&F powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F 3 mm thick figured glass pin headed type and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and directed.
S&F in repair stainles steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with alluminium staple and around all beading complete all as specified and directed.
Dismantling water tanks of capacity exc 500 but not exc 1000 ltr capacity complete all as specified and directed.
S&F rotational moulded polythene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity with and including 25mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
Excavation in trenches not exc. 1.50m wide and not exc. 1.50m in depth for foundation etc or for manholes cesspits, shafts etc not exc 10 sqm on plan and getting out in hard/ dense soil complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m where directed at a level n.exc 1.50m above the starting point complete all as specifed and directed.
Return filling, in including spreading, levelling, watering and levellng and well ramming in layers not exc 25 cm compleate all as specified and directed.
Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar complete all as specified and directed.
M&L for cutting holes into or through brick walls built in brick walls built, in cement mortar or cement lime morta and stone walls built in lime mortar or walls of lime concrete n.exc 150 sqcm complete all as specified and directed.
M&L for cement concete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes of 160mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for unplasticised PVC pipe 160mm dia type 'B' with wall thickness 4mm (Min) of pressure rating 4 KN/Sqm laid in trenches and jointed with cement solvent including testing complete all as specified and directed.
Dismantling of asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof coverings complete all as specified and directed.
S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F rolled mild steel sections channel angle tee section and in tubular section as in main and cross beams, hip and jack rafters; purlins,post where connected to common rafters and running rails fixed with angle cleat or other connecting plates conforming to Fe 410-W Gde-E-250, quality A complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section in any position as in framed work complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
S&F framed work such as gate, grills, gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes; framed guard ; barred iron doors; ladders ; framed balusters; walk ways; railing and similar work Con-forming to Fe 290 Gde E-165 complete all as specified and directed.
M&L joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-W (Gde E 250 ) quality A complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces using WPC where ever required as per manufacturerer's instructions and finishing the surface even and smooth (without using extra cement) etc. including finishing even and fair complete all as specified and directed. Note:- WPC shall be measured and paid separetely.
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying a layer of 2mm thick wall care putty and apply two coats of exteriar emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying a layer of 2mm thick wall care putty and apply two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered wall surfaces and applying a layer of 2mm thick wall care putty and apply two coat of exteriar emulsion paint over a coat of primer complete all as specified and directed.
S&F in repair 25mm dia gun-metal, fancy type, chromium plated with long shank and cup (concealed type) globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair decorative stainless steel tubular curtain rail of 25mm dia including six nos curtain ring per running mtr and one number of brackets on each end and one no of globe on each end of the rod per opening of door/ window complete all as specified and directed.
M&L for preparation of old or previously treated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old or previously treated steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D2 using 40mm graded agg as in plinth protection incl all necessary form work complete all as specified and directed.
M&L for coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade, incl bedding layer of 20 mm thick sand cushning for laying floor finishes complete all as specified and directed.
M&L for leak seal self adhesive water proof sealing tape 100 mm size for water leakage fixed complete all as specified but the work to be carried at an height upto 16 meter from FFL. (Note. All necessary removing old treatment, scaffolding, safety arrangement shall be made by the contractor and quoted rate shall deemed to be this aspect and nothing extra shall be admissible on this account.)
M&L for steel work in tubular trusses/ post/ purline including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone agg) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone agg) as in foundation, filling and mass concrete complete all as specified and directed.
S&F in repair double layered vaccum glass consisting 10mm thick acoustic toughened glass (approved by GE) having 1.14mm PCB lamination for outer face and 10mm thick toughened float glass for inner face with a gap of 10mm between both glass sheet duly thermatically sealed with silicon sealent all around and entrapped air between both glass pane exc 2 sqm duly fixed with and including suitable size rubber gasket of white PVC, Narmada rope, outer aluminium frame of size 100x44mm (Heavy weight ) and beading square 25mm pipe (Heavy weight) complete all as specifid and directed. (Note : The glass panes shall have seamless joints, space in between two glass layers shall be thermetically sealed and entrapped air shall be dehydrated with drying agent. Cost of rubber gasket narmada rope , outer aluminium frame of size 100x44 mm (Heavy weight) and beading square 25mm pipe (Heavy wight ) and other fixing accessories as required fixing of glass with aluminium frame shall be deemed to be included in uni rate quoted by contractor of this item)
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each pane complete all as specified and directed.
S&F in repair of galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M&L for new plastered surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified and directed.
M&L for removing existing painting, scraping, brushing, cleaning of existing treatment of old surfaces of wall/ chhaja etc and applying two coat of Extrior emulsion over a coat of primer complete all as specified and directed.
Taking down carefully aluminium/ copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights, bells etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and as directed.
S&F point wiring for one light point/ fan point/ one bell controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor (FRLS) cable earth wire and connected to earth, etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. (Note:- wiring shall be done in colour coding as directed by Engineer in charge)
All as per item No.97 above but one socket outlet 5 Amps on the same board.
All as per item 97 above but one socket outlet 5 Amps on the independent board
All as per item No 97 above but wiring with 2.5sqmm copper wire (FRLS) PVC and 2.5 sqmm earth (FRLS) wire for socket outlet 5 pin 15 amps on independent board.
S&F lamp holder (dome type) PVC insulated body with cord grip cap for angle/ battern fitting complete all as specified and directed.
S&F switch piano flush type single pole, one way 5 Amp complete all as specified and directed.
S&F switch piano, flush type single pole 15 Amp complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
S&F bell push, flush type, 5 Amp complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existig phenolic laminated sheet complete all as specified and directed.
S&F bell electric type AC 230 volts, 50 Hz complete all as specified and directed.
S&F ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed.
S&F LED light fitting 1x 10w bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F sheet metal enclosure for DB SPN 8 way with 200 Amp rated bus bar 240 Volts, double door including blanking plate as required complete all as specified and directed.
S&F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F 415V 10KA 'B' curve miniature circuit breaker (MCB) of triple poles neutral/ four pole (TPN/ FP) and current carrying capacity 40 to 100 Amp, in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F exhaust fan made of sturdy engineering plastic type ISI mark, copper winding of sweep 300 mm size complete with louvers including cutting opening through brick/ stone/ PCC block wall, making of holes and grouting of suitable size of nut and bolts for 300 mm exhaust fan and making good dismantling portion and making connection with wire of suitable size and connected accessories complete all as specified and directed.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
M&L for earthing complete with galvanized sheet earth plate electrodes 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/ steel of size 75x75x25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core laid in trenches or passing through pipes/ ducts and including making good disturbed as per existing surface including taking down old LT U/G cable from trenches/ protection pipe etc complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core laid in trenches or passing through pipes/ ducts and including making good disturbed as per existing surface including taking down old LT U/G cable from trenches/ protection pipe etc complete all as specified and directed.
M&L for providing dry sand cushioning to underground cable including punning down of sand in layers complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
M&L for brick sub class 'B' old size brick for protection of cable complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 50 mm bore, light grade with all fittings laid in trenches / pole post /under culvert/ under road including nut, bolts and clamps for fixing to pole etc. complete all as specified and directed.
M&L for cutting the road for laying GI pipe and making good the entire distrubed surface as exisitng after laying the pipe complete all as specified and directed.
M&L for sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including rigid non metallic PVC conduit (ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified and directed. Note:- 1 The cost of earth wire is included in the quoated rates. 2. Two run of 4 sqmm, one run of 4 sqmm and one run of PVC conduit will be measured as one unit ie one running metre.
M&L for sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including rigid non metallic PVC conduit (ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/ terminal boxes, all fittings and accessories fixed concealed with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note:- 1 The cost of earth wire is included in the quoted rates. 2. Two run of 6 sqmm, one run of 6 sqmm and one run of PVC conduit will be measured as one unit ie one running metre.
S&F LED lights fitting 1x 20W (warm/ milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F sheet metal enclosure for DBs (double door type) triple pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed and concealed in wall including taking down unserviceable main switches MCB DB's of any make and type including teakwood board etc. and making good the disturbed surfaces as per existing surface complete all as specified and directed.
S&F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp 240 volts complete all as specified and directed.
M&L for cutting of existing wall and making the opening for exhaust fan 300 mm sweep (finished size) including plastering and matching colour of wall complete all as specified and directed.
Taking down old beacon light rotating type having lamp 4 sealed beam 500W PAR 64 Sodium vapor rotating type (Manairco Model AB-1000F) with motor fabricated box complete all as specified and directed.
Supply, fixing, testing and commissioning of LED Beacon Strobe lights Lokozo, Colour: White and Green, Power: 800 Watt for white, 800 Watt for Green, Operating Mode: Alternate Flashing @ 30 Flashes Per Min Operating Voltage 230V, 50Hz with intensity controller and control panel for the controller complete all as specified and directed.
Taking down carefully of existing old 400 watt sodium vapour Hi-bay light at 15 mtr height at hanger complete all as specified and directed.
supply, fixing and testing of 200 watt Highbay luminaries with pressure die-cast housing, toughened glass and 130 lm/W 4kV inbuilt and 10kV external surge protection IP 66 ingress protection with additional safety complete all as specified and directed.
M&L in repair of true online UPS system 10 KVA, 3 phase input and input voltage 340 to 440V, 50 Hz (47 to 53 Hz) output voltage- 230V, Single phase including replacement of burnt/defective part of the system and make the system operational condition. Consisting with following works :- (a) Check operational mode of system (normal, battery, bypass, manual bypass, ECO mode, auto restart mode etc.). (b) Checking of electrical connection thoroughly . (c) Replacement of rectifier, bypass indicator, diode, capacitor, ICs, and inverter, load/unload indicator etc and other electronics component required on site. (d) Replacement u/s battery of capacity 12V, 26 Ah - 30 Nos (d) Repairing of defective/ burnt/ unserviceable part of rectifier and inverter and make the system in operational condition complete all as specified and directed.
Taking down old unserviceable junction box and supply and fixing pole mounting box/ junction box made out of 1.66mm thick MS CRCA sheet/ fiber sheet of size 230 x170 x 105 mm complete suitable for three phase connection with clamps of flat iron/GI off size 25 x 4 mm including suitable size nut, bolts, washer etc to fix on pole and provide with hinged door and locking system all painted with two coats of synthetic enamel paints over one coated red oxide paint and comprising of the following :- (i) AI bus bar 150mm long size 20 x 50 mm fixed on four Nos porcelain insulator each bus bar provided with four Nos of Nuts, bolts, washer for incoming and outgoing cable. (ii) MCB SP 230V 5 to 32A, 10 KA – 1 Nos.
Taking down old unserviceable 400 watt halogen light and Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp, average life of street light not less than 50000 hours, including clamps, nut, bolts, bracket made of flat iron strip 25x4 mm bent to shape for LED fitting for fixing on channel/ steel surface complete all as specified and directed.
Taking down old cable and supply, laying, connecting, testing and commissioning of 35 Sqmm 3.5 core earthed system under ground LT XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe with suitable size glands, crimping type lugs and including making good of disturb surface of road as per existing complete as specified and directed.
Supply, fixing, testing and commissioning of fire alarm control panel complying with BS EN 54 4 loop with capacity from 99 dectectors & 99 modules and upto 200 detectors and modules (per each loop) complete all as specified and directed.
Supply, fixing, testing and commissioning of detectors complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS : 11360 complete all as specified and directed.
Supply, fixing, testing and commissioning of addressable manual call point resettable type complete all as specified and directed.
Supply, fixing, testing and commissioning of addressable electronic sounder cum strobe complete all as specified and directed.
Supply, fixing, testing and commissioning of 250 watt amlifier complete all as specified and directed.
Supply, fixing, testing and commissioning of microphone set complete all as specified and directed.
S&F 1.5 sqmm 2 core armoured copper cable FRLS (red colour) with all fixing accessories as per site requirement complete all as specified and directed.
M/S Rajeev Sharma and Co.
ng associate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .