Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | NTR | ANDHRA PRADESH | 520001 | ₹30.7 L Quoted ₹30.9 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹32.7 L+₹1.8 L (5.90%)Rejected-AOC 38 39 86 BAPUJI NAGAR 104 AREA POST VISAKHAPATNAM 530 007 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530007 | ₹32.7 L+₹1.8 L (5.90%) | L2 | Rejected-AOC Not Admitted |
| 3 | L3₹33.4 L+₹2.6 L (8.26%)Rejected-AOC D NO 49 23 27 A FLAT NO 301 3RD FLOOR SRI SAI TIRUMAL ENCLAVE LALITHANAGAR VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹33.4 L+₹2.6 L (8.26%) | L3 | Rejected-AOC Not Admitted |
| 4 | L4₹34.2 L+₹3.3 L (10.6%)Rejected-AOC 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹34.2 L+₹3.3 L (10.6%) | L4 | Rejected-AOC Not Admitted |
| 5 | L5₹34.4 L+₹3.6 L (11.5%)Rejected-AOC | ₹34.4 L+₹3.6 L (11.5%) | L5 | Rejected-AOC Not Admitted |
| Sl No | Description | Qty | Unit | REAL ENGINEERING WORKS L10 | pavan putra enterprises L6 | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L11 | AMBIKAA ENGINEERING L8 | ANJALI CONSTRUCTIONS L12 | G Srinivas Rao L3 | MVV Prasad L4 | sai ganesh enterprises L1 | INDRA CONSTRUCTIONS L2 | V R K CONSTRUCTIONS L7 | K.ADITYA ENGINEERING CONTRACTORS L5 | prasad constructions L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: B/R WORKS | |||||||||||||||
| 1.00 | S&F for anodised aluminium snap grid frame work of size 605 mm x 605mm for false ceiling complete all as specified and directed. [Note : The quoted rate is inclusive of all scaffloding and safety arrangements required for execution of work] | 2,906.54 | Sqm | 400 ₹11,62,616 | 130 ₹3,77,850.2 Lowest | 250 ₹7,26,635 | 504 ₹14,64,896.16 | 600 ₹17,43,924 | 280 ₹8,13,831.2 | 440 ₹12,78,877.6 | 350 ₹10,17,289 | 369 ₹10,72,513.26 | 419 ₹12,17,840.26 | 440 ₹12,78,877.6 | 439 ₹12,75,971.06 |
| 2.00 | M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as spcified and directed | 2,906.54 | Sqm | 25 ₹72,663.5 Lowest | 160 ₹4,65,046.4 | 80 ₹2,32,523.2 | 100 ₹2,90,654 | 50 ₹1,45,327 | 190 ₹5,52,242.6 | 223 ₹6,48,158.42 | 50 ₹1,45,327 | 87 ₹2,52,868.98 | 104 ₹3,02,280.16 | 52 ₹1,51,140.08 | 88 ₹2,55,775.52 |
| 3.00 | S&F 8mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as spcified and directed | 2,906.54 | Sqm | 600 ₹17,43,924 | 260 ₹7,55,700.4 Lowest | 720 ₹20,92,708.8 | 450 ₹13,07,943 | 600 ₹17,43,924 | 420 ₹12,20,746.8 | 410 ₹11,91,681.4 | 400 ₹11,62,616 | 357 ₹10,37,634.78 | 509 ₹14,79,428.86 | 440 ₹12,78,877.6 | 457 ₹13,28,288.78 |
| 3.01SCHEDULE 'A' PART-II: E/M WORKS | |||||||||||||||
| 4.00 | Taking down aluminium / copper point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, cover plate , frame and light fittings etc. and making good the disturbed surface on walls floors complete all as specified and directed by Engr-in-charge. | 585 | Each Point | 25 ₹14,625 | 180 ₹1,05,300 | 40 ₹23,400 | 50 ₹29,250 | 18 ₹10,530 | 100 ₹58,500 | 30 ₹17,550 | 50 ₹29,250 | 111 ₹64,935 | 32 ₹18,720 | 12 ₹7,020 Lowest | 88 ₹51,480 |
| 5.00 | M&L in for point wiring with 1.5sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in exisitng conduit and inciluding extended concealed conduit beneath the newly provided false ceiling with not less than 20mm dia including for mounting switches/Sockets, accessories such as spacers, saddles, junction boxes, metal box & cover plate of switch board for one light / fan point controlled by one switch complete including taking down existing wiring complete all as specified and directed by Engg-in-Charge.
Note- The extended PVC Conduit Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and poining in cement mortar and making good for same unit rates are inculded for same | 585 | Point | 800 ₹4,68,000 | 1,500 ₹8,77,500 | 1,000 ₹5,85,000 | 600 ₹3,51,000 | 761 ₹4,45,185 | 850 ₹4,97,250 | 25 ₹14,625 Lowest | 800 ₹4,68,000 | 787 ₹4,60,395 | 689 ₹4,03,065 | 750 ₹4,38,750 | 835 ₹4,88,475 |
| 6.00 | Fixing in repairs of modular fan regulators any module any type retrieved from item 1 above complete all as specified and directed. | 100 | Each | 550 ₹55,000 | 1,017 ₹1,01,700 | 550 ₹55,000 | 200 ₹20,000 | 120 ₹12,000 | 50 ₹5,000 Lowest | 425 ₹42,500 | 50 ₹5,000 Lowest | 75 ₹7,500 | 59 ₹5,900 | 75 ₹7,500 | 169 ₹16,900 |
| 7.00 | S& F fan regulator modular one way 6 Amps,as per sample 230V complete all as specified and directed. | 95 | Each | 370 ₹35,150 | 260 ₹24,700 | 550 ₹52,250 | 350 ₹33,250 | 190 ₹18,050 Lowest | 450 ₹42,750 | 280 ₹26,600 | 285 ₹27,075 | 865 ₹82,175 | 302 ₹28,690 | 350 ₹33,250 | 457 ₹43,415 |
| 8.00 | S& F switch modular one way 6 Amps,1 module 230V complete all as specified and directed. | 63 | Each | 155 ₹9,765 | 307 ₹19,341 | 80 ₹5,040 | 150 ₹9,450 | 60 ₹3,780 Lowest | 190 ₹11,970 | 150 ₹9,450 | 125 ₹7,875 | 222 ₹13,986 | 95 ₹5,985 | 110 ₹6,930 | 529 ₹33,327 |
Tender Value
₹43.2 L
EMD Value
₹86,400
Closing Date
2 May 2026, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF DEFICIENT FALSE CEILING FOR TOP FLOORS OF BUILDING NO P 01 TO P 11 AT NAUSHAKTI VIHAR UNDER GE ND VISAKHAPATNAM
2026_MES_759709_1
8580/GEND/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹86,400
Yes
21 Aug 2026
9 Apr 2026
4 May 2026
9 Apr 2026
2 May 2026
24 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.01 | SCHEDULE 'A' PART-I: B/R WORKS | - | - | - | - |
| 1 | M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as spcified and directed | 0.6 | Sqm | - | - |
| 2 | M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as spcified and directed | 0.6 | Sqm | - | - |
| 3 | S&F 8mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as spcified and directed | 0.6 | Sqm | - | - |
| 3.01 | SCHEDULE 'A' PART-II: E/M WORKS | - | - | - | - |
| 4Taking down aluminium / copper point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, cover plate , frame and light fittings etc. and making good the disturbed surface on walls floors complete all as specified and directed by Engr-in-charge. | |||||
| 5M&L in for point wiring with 1.5sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in exisitng conduit and inciluding extended concealed conduit beneath the newly provided false ceiling with not less than 20mm dia including for mounting switches/Sockets, accessories such as spacers, saddles, junction boxes, metal box & cover plate of switch board for one light / fan point controlled by one switch complete including taking down existing wiring complete all as specified and directed by Engg-in-Charge. Note- The extended PVC Conduit Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and poining in cement mortar and making good for same unit rates are inculded for same | |||||
| 6Fixing in repairs of modular fan regulators any module any type retrieved from item 1 above complete all as specified and directed. | |||||
| 7S& F fan regulator modular one way 6 Amps,as per sample 230V complete all as specified and directed. | |||||
| 8S& F switch modular one way 6 Amps,1 module 230V complete all as specified and directed. | |||||
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender8580.pdf
Tender Documents • 0.92 MB
BOQ_850928.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .