Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.7 LAccepted-AOC | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹15.8 L+₹1.1 L (7.78%)Rejected-Finance HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | PANCHKULA | HARYANA | 134118 | L-2 | Rejected-Finance Highest |
Tender Value
₹13.0 L
EMD Value
₹26,060
Closing Date
18 Oct 2021, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of ATC and Passenger Terminal Building at Civil Aerodrome, Pinjore in Panchkula Distt. (Pdg. E.I Only).
2021_HRY_190250_1
PWD/Elect-KNL/Elect-AMB/110186
Open Tender
Construction Works
Works
240 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹26,060
Yes
12 Jan 2022
29 Sept 2021
19 Oct 2021
29 Sept 2021
18 Oct 2021
29 Sept 2021
Amount
CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. 48" (1200mm) HRS No. 20.71.1
Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge HRS No. 20.72
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B HRS No. 23.2.1.2
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B HRS No. 23.2.2.2
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B HRS No. 23.2.4.2
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B HRS No. 23.2.5.2
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HRS No. 23.5.6.1
1 run of Size 2.50 Sqmm(1.1.80mm) HRS No. 23.5.6.2
1 run of Size 4 Sqmm(1/2.24mm) HRS No. 23.5.6.3
1 run of Size 10 Sqmm(1/3.50 mm) HRS No. 23.5.6.5
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. HRS No. 23.6.6.1
MS pipe of 25 mm dia. HRS No. 23.6.6.2
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HRS No. 23.7.6.2
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data HRS No. 23.8.10.1
4 Modules HRS No. 23.8.10.3
6 Modules HRS No. 23.8.10.4
12 Modules HRS No. 23.8.10.6
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HRS No. 23.8.11.1
15 amp 1 way switch HRS No. 23.8.11.3
5 amp Socket HRS No. 23.8.11.4
15 amp 6 pin Socket HRS No. 23.8.11.5
Step type Fan Regulator 2 modules 300 watt HRS No. 23.8.11.7
Blanking plate HRS No. 23.8.11.10
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required HRS No. 23.2
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp HRS No. 23.22.1.9
Supply and erection of sheet steel enclosures 1 Pole / 2 pole / 4 pole on wall/on existing pedestal complete with necessary connections etc, :- S.P.N or D.P enclosure suitable for DP MCB HRS No. 23.22.3.2
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HRS No. 23.22.4.5
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) HRS No. 23.22.4.7
TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) HRS No. 23.22.4.8
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HRS No. 23.22.5.1
40 amp to 63 amp. MCB's TRIPLE POLE HRS No. 23.22.5.6
40 amp to 63 amp. MCB's FOUR POLE HRS No. 23.22.5.8
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HRS No. 24.1.3
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HRS No. 24.1.5
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HRS No. 24.1.7
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HRS No. 24.1.8
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HRS No. 24.1.11
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. HRS No. 24.1.13
M/S GARG ELECTRICAL
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .