| 1 | L1₹18.8 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹19.8 L+₹45,542.50 (2.35%)Rejected-AOC 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹21.0 L+₹1.6 L (8.24%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL 246155 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246155 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹21.4 L+₹2.0 L (10.2%)Rejected-AOC 199 79 SADAR BAZAR LANSDOWNE TAHSIL LANSDOWNE | L4 | Rejected-AOC Not Lowest |
Tender Value
₹24.1 L
EMD Value
₹48,300
Closing Date
10 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE HILLS DEHRADUN
HQ CWE HILLS DEHRADUN MALL ROAD DEHRADUN CANTT-248003
ADDN/ ALTN OF KITCHEN CUM PANTRY IN OFFICERS MESS AT GRRC LANSDOWNE
2022_MES_567234_1
87154/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Lansdowne
Class E Cat a i
7 documents required · 7 mandatory
₹500
AGE I Lansdowne
₹48,300
17 Feb 2023
3 Dec 2022
17 Jan 2023
3 Dec 2022
10 Jan 2023
28 Dec 2022
Amount
Demolition of PCC in ground floor and pavings not exc 15 cm thickness below or above ground level including removal of rubbish out side MOD land complete all as specified and directed.
M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concrete complete all as specified and directed.
Dismantling of wall tiling including cement mortar bedding (but not backing) and rubbish off the premises from MoD land complete all as specified and directed
M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick, of following size, as in floor etc with and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed :- Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I).
Area of each tile exc 0.11 Sqm but not exc 0.18 Sqm.
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8mm thick, as in dado etc including 10mm thick rendering in CM (1:3), set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I).
M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror finish polishing over and including 15mm thick screed bed in cement mortar (1:3) complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
Description same all as per item No 06 above but, as in skirting/ dado (10-12mm thick Kota stone) over and including 10mm thick rendering in cement mortar (1:3) complete all as specified and as directed.
M&L for 18-20mm thick granite stone slab (of any type) work (table rubbed and mirror finish polished) in steps, jambs, pillars, window-cills, cooking platforms and like bedded over and including 15mm thick screed bed in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.
Taking up or down steel tubing 15mm dia bore and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20mm dia bore and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complee with all fittings (such a sbends, elbows, Tee short pieces, connectors back nuts,diminishing pieces, caps and plugs, unions etc) of nominal bore 15mm ISI Marked with all fittings (heavy grade ISI Marked) complete all as specified and directed.
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complee with all fittings (such a sbends, elbows, Tee short pieces, connectors back nuts,diminishing pieces, caps and plugs, unions etc) of nominal bore 20mm ISI Marked with all fittings (heavy grade ISI Marked) complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth complete all as specified and directed
Taking down cement plaster, any desription on brick or stone walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
Material & Labour for Rendering 15 mm thick in CM 1:6 on brick/stone or concrete surfaces finish even & smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick/stone or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.
Material & labour for Rendering 5 mm thick CM 1:3 on brick or concrete surfaces of ceiling /chajja's finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of old decorated surface of exterior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machineand with and including application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper complete all as specied and directed at site by Engineer-in-Charge.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine with and including application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper complete all as specied and directed at site by Engineer-in-Charge.
M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer of same make all as specified and prescribed by manufacture of paint/ distemper, by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.
M&L for preparation of old decorated surface of interior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer of same make all as specified and prescribed by manufacture of paint/ distemper, by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge. Note for item No 20 to 23 :- (i) The old/ New surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) Before commencing the work, contractor will got the written approval from GE/ AGE (I) for the make and colour / shade (tint). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed
M&L for preparation of old painted surface of wood and wooden based material of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (1st Quality) with and including complete removing of old paint by paint removers or burning off by blows and cleaning with scrapers, any number of coats complete all as specified and as directed.
M&L for preparation of old painted steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (1st Quality) with and including complete removing of old paint by paint removers or burning off by blows and cleaning with scrapers, any number of coats complete all as specified and as directed.
Taking down door / window frame with shutter (without taking of shutter from the frame) area not exc 1.5 sqm complete all as specified and directed.
M&L preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide primer all as specified
Dismantaling of plain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Make : HIL Ltd / Ispat Industries Ltd / Tata Blue Scope Steel Ltd / Cril Color Roof India Ltd.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed . Make : HIL Ltd / Ispat Industries Ltd / Tata Blue Scope Steel Ltd / Cril Color Roof India Ltd.
S & F 18mm thick PVC solid both side prelim celuka cup boards, drawer etc with shelf and shutter including lipping to edges of exposed surface including provision of fixing arrangement and catcher in each shutter and frame complete all as specified and directed.
S&F in repair Stop Angle valve cast copper alloy chromium plated 15mm dia, screwed down, high pressure with capstan handle, screwed both ends for iron pipes or for unions and fixed ,complete all as specified. Make : Jaquar, Cat Part No. SQT-526-NKN / Cera, Cat Part No. F1015201 or equivalent of make as specified.
S&F extruded aluminium alloy handles, fabricated type, anodised (ISI marked) of 150mm long size complete all as directed and specified.
S&F anodised aluminium barrel tower bolts (ISI marked) of extruded section of 150mm long size complete all as directed and specified.
S&F as in repair stainless steel kitchen plate rack of size 24x36x10 inch of minimum thickness 0.85mm including necessary drilling, fixing with screw, plugs in kitchen etc complete all as specified and directed Make : Prayag Polymer Pvt Ltd, Cat Part No. P-336 or equivalent of make as specified.
Taking down chowkats with shutter n. exc 1.5 sqm each (without taking of shutter from the frame) complete all as specified & directed.
Taking down Chowkats with shutter exceeding 1.5 Sqm but n. exc 4.00 Sqm each (Without taking off shutters from the frames) complete all as specified & directed
Taking down shutters of any description, area not exceeding 1.00 sqm each complete all as specified.
M&L for cast iron Nahani trap with grating including jointing to waste pipe fixed in PCC (1:2:4) type B1, for 75mm size complete all as specified & directed.
S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed. Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc. Make : Jaquar, Cat Part No– ECS-WHT-803 / Cera, Cat Part No- S2040166 / Prayag, Cat Part No - 4645.
M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
M&L for brick work with old size half brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
S&F in repairs sinks duet regular double bowl made of stainless steel 1mm thick 304/204 super steel kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 1143x510x203 mm and bowl size 510mm x 405mm x 203mm complete all as specified and directed Make : Prayag Polymers Pvt Ltd, Cat Part No.-1350D or euivalent of make as epecified.
Supply only PVC connection 15 mm dia, 450 mm long (ISI marked duly approved by AGE (I) Lansdowne) including brass ferrules on both ends complete all as specified and directed
Supply only 15mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed. Make : Jaquar, Cat Part No– DLX-510KN / Cera, Cat Part No.-F1020101 or euivalent of make as epecified.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of following capacity of tank complete all as specified and as directed:-
Capacity 1000 Ltrs
S&F of 20 mm bore ball valves (ISI Marked only), high pressure, PTMT, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair 15 mm bore bib taps, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : Jaquar, Cat Part No– APR-101037 / Cera, Cat Part No.-F1020151 or euivalent of make as epecified.
S&F in repair 15 mm bore stop valves, fancy type, chromium plated, cast copper alloy, long shank and cup (concealed type) screwed down, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed. Make : Jaquar, Cat Part No– SQT-514AKN / Cera, Cat Part No.-F1020361 or euivalent of make as epecified.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F PVC (SWR) pipes (ISI Marked) single socketed in any length with rubber ring joints and laid in trenches or in floor of 110mm bore size complete all as specified and as directed.
S&F PVC (SWR) bends with access door (ISI Marked) any radius of 110mm dia size complete all as specified and as directed.
Dismantling of timber scantling 40 sqcm and over in section, in any position as in unframed work complete all as specified and as directed.
M&L for formwork for rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed.
M&L for RCC (1:2:4) Nominal mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2, (40 mm graded stone agg) as in sub base of floor/ hardstanding/ footpath complete all as specified and directed.
M&L for 60mm thick coloured rubber moulded glossy finish machine pressed precast concrete interlocking paver block, M-35 Grade with pre-polished, coloured/ laquar finish any shape and size, as approved confirming to IS 15658-2006 with and including 25mm thick sand/ stone dust cushining complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil comlete all as specified and directed.
S&F mild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 with and including one shop coat of zinc chrominium primer paint complete all as specified and as directed. Note : The rates quoted deemed included for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.
S&F False Ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 : 1987, Non Combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T-runners of size 15 x 32 mm of length 3000 mm, cross -T size 15 x 32 mm of length 1200 mm, and secondary intermediate cross-T of size 15 x 32 mm of length, 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) i.e, 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hangar rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, Galvanised iron perimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plug at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing, and as per directions of engineer-in-charge with semi perforated 12mm thick micro tabular edged GRG false ceiling tiles complete all as specified and directed.
Dismantaling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F Powder coated of any colour (minimum thickness of powder coating 50 micron), aluminium door shutters, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F mortice lock (ISI marked) of brass of size 100mm, 4 lever, vertical type fixed to door complete all as specified and as directed.
S&F Powder coated of any colour (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden/ PVC/ aluminium beading, in square n. exc 0.5 sqm in each pane incl punching or drilling old glazing pins/spring clips and removing complete all as specified and as directed.
S&F 12 mm thick prelaminated particle board exterior grade, ISI marked, one side with decorative choice lamination and other side balancing white fixed with aluminium frame work complete all as specified and directed.
M&L for walling of random rubble, uncoursed well bonded, bedded and solidly hearted, stone masonary work built in CM (1:6) complete all as specified and as directed. Note :- Only quantity of PCC bond stone to be deducted from quantity of random rubble masonary.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surfacae not exceeding 40mm to face stone (Lime or sand stone) and dressing of face beds and joints, as specified of random rubble walling, uncoursed or brought upto course complet all as specified and directed.
M&L for raised pointing in cement mortar (1:4) to random rubble masonary uncoursed or brought upto course complete all as specified and directed.
S&F stainless steel 304 grade of steel for making steel railing/ racks in kicthen of any thickness made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel boltsand any size including fabrication and fixing in wall/floor as directed by engineer in charge complete all as specified and directed.
Taking down carefully existing unserviceable aluminum/ copper point wiring of any description & in any position with and including existing wooden battens/conduits fixed on surface or concealed and all fittings including sunken/surface boxes & terminal boxes of any description, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings/ tube light fittings, lamp holders etc including sunken boxes / junction boxes and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed. Note:- 1. Old fittings/ fixtures / accessories like switch, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. 2. Only old unserviceable items will be considered in credit Sch.
M&L for point wiring of one light/ fan/ exhaust fan/ call bell point controlled by one way 5 Amp switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
Description same all as per serial Item No 76 here in above but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
Description same all as per serial Item No 76 here in above but 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size complete all as specified and directed.
Description same all as per serial Item No 76 here in above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed. Make: Legrand, Cat Part No: 6734 01/ Indo Asian, Cat Part No: 800000 / Havells, Cat Part No. ACWSXXW101.
S&F bell push modular single pole one way 6 Amps, 1 module , ISI marked complete all as specified & directed. Make:- Legrand, Cat Part No: 6730 22 / Indo Asian, Cat Part No: 800007 / Havells, Cat Part No. ACWSBXW101.
S&F Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. Make: Legrand, Cat Part No: 6734 52 / Indo Asian, Cat Part No: 800020 / Havells, Cat Part No. ACWKPXW063
S&F switch modular one way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand, Cat Part No: 6734 11/ Indo Asian Cat Part No: 800002 / Havells, Cat Part No. ACWSXXW161
S&F modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed. Make:- Legrand, Cat Part No: 6734 55 / Indo Asian, Cat Part No: 800022 / Havells, Cat Part No. ACWKCXW163.
S&F lamp holder (Angular/Straight ), insulated body, with back plate (ISI Marked) for batten fitting complete all as specified & directed
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals ISI Marked complete all as specified & directed.
Supply and fixing bell ding dong 50 HZ AC 230/240 volts single pole, complete all as specified & directed.
S&F MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure,double door type complete all as specified and as directed.
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and as directed.
Supply & fixing MCB , SP AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing MCB, SPN, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 6 Sqmm with 6 Sqmm FRLSH PVC insulated, unsheathed, stranded copper conductor cable as earth wire in existing surface/concealed PVC conduit and earth wire connected to common earth dolly all as specified & directed. Note: Three run of 6 sqmm cable shall be measured as one unit
Supply and fix surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. Model: SZSLBMX020 of Shakti or equivalent make of Philips or crompton. Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period. Make: – Shakti Fixture Pvt Ltd, Cat Part No. SZSLBMX020 / Havell, Cat Part No. LHEXBLP7PN1W020 or equivalent of make as specified.
Supply and fix LED street/security light fitting 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts AC, 50 HZ, consisting of reflective lens wired with approximate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level > 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 120 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K- 6500 K including fixed on wall with 02 Nos MS clamp made out of 40 x 6 mm F1 and bracket made out of 40 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volta grade all as specified and as directed by Engr-in-Charge Make : shakti Cat Part No : SZPSLPM020/ ENDURAPEARLSL20W of HEVELLS or equivalent of make as specified in Appx "B" (List of make) Note :- (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 & LM 80 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS (iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above. Make – Shakti Fixtures Pvt Ltd, Cat Part No : SZPSLPM020/ Havells, Cat Part No. ENDURAPEARLS20W or euivalent of make as specified.
Supply and lalying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire axmoured, electric power cables (heavy duty) with alumimnium conductor, 1100 volts, grade crosws sectional area 16 sqmm 4 core incl earth work, sand cushioning, brick or PCC covering, light grade GI tubing where necessary and testing complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation/for poles etc complete all as specified and directed.
Returning filling in soft/ loose soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/ loose soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and spread fine river sand in trenches as cushioning to underground cable on top and bottom of cable all as specified (measurement to be taken after punning down).
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed at site.
Supplying, laying & jointing GI water tubing, 40 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. for cable protection complete all as specified and directed .
Supply & Fixing of Exhaust Fan of 300mm Sweep, Steel body AC Single phase, complete with blades, frame and louvers and including three core flexible PVC copper conductor of size 1.5 Sqmm from ceiling rose/ connector to Exhaustn fan complete all as specified and directed.
Supply and fix Water heater storage type water heater (Geyser) capacity 25 litres.BEE 5 star rated including grouting the nut bolts - 04 Nos,PVC Connection Pipe - 02 Nos etc complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
RAMAPATI ENGINEERING SERVICES
PIONEER REFRIGERATION AND ELECTRICALS
M/S Balaji Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .