GE Kargil
GE Kargil ladakh 194103
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIFICATION INCLUDING STREET LIGHTS AND E/M INSTALLATIONS OF VARIOUS UNITS AT BHIMBAT AND THASGAM UNDER GE KARGIL
2021_MES_436157_2
GE/K-17/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
thasgam
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Kargil
₹28,000
Yes
23 Jul 2021
31 May 2021
19 Jun 2021
31 May 2021
17 Jun 2021
3 Jun 2021
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard/dense soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
Supply and laying un reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mm
Replacement of pin type insulator, composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 1100 volts grade, complete all as specified.
Replacement of pin type insulator, composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 11000 volts grade, complete all as specified.
Dismantling of old ACSR conductor or service feeder distribution span and S&F in repair ACSR conductor of (weasel) 6/2.59, straching properly on insulators and binding with aluminium binding wires,jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x230x6 mm, stay bow,loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 including taking out old stay assembly.
Loop type insulator composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 1100 volts grade, complete all as specified.
Loop type insulator composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 11000 volts grade, complete all as specified.
Disc type insulator composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 11000 volts grade, complete all as specified.
Supply and fixing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts
Supply and fixing of gang operated air break switch Triple pole, mechanically operated, mounted on composite/poymer insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps for 11000 volts
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 95 sq. mm 3.5 core complete all as specified
All as per ser item No.15 but for 70 Sqmm 3.5 core
All as per ser item No.15 but for 50 Sqmm 3.5 core
All as per ser item No.15 but for 25 Sqmm 4 core
All as per ser item No.15 but for 16 Sqmm 4 core
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32x6 mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron or steel as shown in electrical plate No. 3 connected to Earthing test point all as specified and directed on testing on completion.
S&F MCCB 400 Amps,4 pole, 415 volts, 36 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F MCCB 250 Amps,4 pole, 415 volts, 36 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F MCCB 160 Amps,4 pole, 415 volts, 36 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F Changeover switch off load of capacity 200 A, 415 Amps, 4 pole, with metal enclosure box
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge.
Pole painting with two coats of black bituminous paint externally through out for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface of existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge.
Supply and lay GI strip of size 32x6 mm for earth continuity burried in ground fixed in wall/floors etc all as directed.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
Plain cement concrete 1:3:6 type C-1 (using 20mm grade aggregate) as in coping including all necessary form works complete all as specified and directed by Engineer-in-Charge
Street light bracket made out of GI pipe 35mm dia light grade 1.2 mtr duly bended in position as per site requirement and including 2 Nos and 2 set MS flat iron clamps of suitable size complete with 03 set nut , bolts and washers for mounting street lights,complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED Flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp
Supply and fixing post top lantern LED type 20 watt 230 watt volts outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete.
Cable junction box of size not more than 250x150x75 mm with 6 Amp MCB SPN and bus bar fixed along the wall/pole without removing and preparation of surfaces for painting externally. Painting the cable junction box complete externally by applying one coat of synthetic enamel paint of approved colour , complete all as specified and directed by the Engr-in-Charge.
PVC cable 1.5 sqmm for controlling street light including clamp, nuts and bolts , complete all as specified and directed by the Engr-in-Charge.
GI tubes galvanised iron light grade 40 mm bore laid in trenches/across roads/alongwith walls/poles as protection to cables and including taking down of old unservicable GI tubing,complete all as specified and directed by the Engr-in-Charge.
Sheet metal enclosure for DB’s, single door single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required, complete all as specified and directed by the Engr-in-Charge.
MCB, Triple pole and neutral, 63 Amp, 415 volts, 10 KA , complete all as specified and directed by the Engr-in-Charge.
MCB, isolator single pole, 40 Amp, 240V, 10 KA, complete all as specified and directed by the Engr-in-Charge.
Earthing complete with steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connecting to the galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of GI and steel earth wire complete all as shown in electrical plate No.3 of MES Schedule 2009 (Pt-I) and connected to earth test point all as specified including testing on completion.
Supply and installation erection commissioing and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole aluminium bus bar 400 amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- MCCB 4 pole 415 volts 160 Amps, 35 KA - 01 No MCCB 3 pole 415 volts 125 Amps, 25 KA - 03 Nos Ammeter 0-400 Amps, size 4"x4" digital along with suitable size CT's-03 Nos( one per Phase)-03 Nos Volt meter 0-500 volts size 4"x4" digital - 01 No LED indicator lamp(RYB) - 01 Set
Supply and fixing of Solar Garden Light high quality mild steel construction duly powder coated ultra bright 12 Nos. white LED 0.25 Watt 1200 lux automatically switches ON the light at dusk and switches OFF at dawn including high capacity lead acid sealed maintenance free rechargeable 2 Nos. 6 Volts 4 AH batteries complete all as specified and directed by Engr-in-Charge. Make- Bhambri Solar Pvt Ltd cat part No. King size KSGL-1 or equivelant of Bajaj or Havells or Syska.
Note : Deduction for amount of Rs 31206.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
JP AND CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .