Tender Value
₹2.5 Cr
EMD Value
₹3.2 L
Closing Date
30 Nov 2020, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
PROVN OF POWER TRANSFORMER INCL 11 KV CONNECTION TO NORTHERN AND CENTRAL SECTOR FROM SOUTHERN SECTOR (33 KV INTRIGATION) AT KOTA MIL STN
2020_MES_372526_1
CEJZ/NIT/KOTA-03 OF 2020-21
Open Tender
Civil Works
Item Rate
365 days
KOTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE KOTA
₹3.2 L
Yes
6 Jan 2021
2 Sept 2020
7 Dec 2020
2 Sept 2020
30 Nov 2020
18 Nov 2020
Amount
Excavation in trenches n.exc 1.50m wide and n exc 1.50m in depth for foundation etc n.exc 10 sqm on plan and getting out in soft & loose soil complete all as specified & directed.
Excavation in trenches n.exc 1.50m wide and exc 1.50m in depth but n.exc 3.0 metre depth for foundation etc n.exc 10 sqm on plan and getting out in soft & loose soil complete all as specified & directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested complete all as specified & directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete complete all as specified & directed.
M & L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified & directed. Note :- Thickness after punning down shall be measured and paid.
Supply and laying un-reinforced precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm all as specified factory made ISI marked complete all as specified & directed.
Supply, laying, connecting and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11 KV grade laid in trenches/ducts/encased in GI pipe/fixed to pole including jointing and testing of size 185 sqmm 3 core complete all as specified and directed. Note :- Excavation, earthwork, PCC cable covers, sand, GI pipe shall be measured and paid seperately.
Supply, laying, connecting and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11 KV grade laid in trenches/ducts/encased in GI pipe/fixed to pole including jointing and testing of size 95 sqmm 3 core complete all as specified and directed. Note :- Excavation, earthwork, PCC cable covers, sand, GI pipe shall be measured and paid seperately.
M&L for cable end termination jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 11 KV grade of size 185 sqmm 3 core complete all as specified and directed.
M&L for cable straight through jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 11 KV grade of size 185 sqmm 3 core complete all as specified and directed.
M & L for cable end termination jointing kit HT 11 KV grade heat shrinkable ,outdoor type complete with jointing material suitable for HT XLPE cable 11 KV graded of size 95 sqmm 3 core compete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply , installation , test and commissioning of 11 KV 630 Amps (IP-54), SF6 gas filled with both side extensible Ring Main unit (RMU), mounted on PCC platform not less than 3 mtr x 1.5 mtr x0.6 mtr, manual operations and with internal copper bus bars. All live parts, bus bars., LBSs, VCBs connections of RMU should be enclosed in Stainless Steel tank of 2.5 +/-0.5 mm thick sealed for life having IP67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. RMU shall have solid earthing system. RMU should complete with all accessories such as Terminal boots, VPIS, FPI, cable supports, mechanical indications for load break switch ON/OFF, VCB ON/OFF, Spring charge, Manometer as per with IEC standards 62271-200. Internal arc type tested for 21KA for 1 sec. VCB/LBS used must be tested for minimum 20 nos of electrical operations in factory. Manufacturer has to submit valid test report. 1 No. incoming (LBSs) and 4 Nos. outgoing (VCBs). Rated voltage should be - 12KV. Rated power frequency voltage- 28KV. Rated lightining impulse withstand voltage - 75KV. Rated current for VCB feeder - 630 A. Rated short time current withstand - 21 KA for 3 Sec. Rated short time making current - 50 KA. Nominal operating gas pressure - 1.2 Bar abs at 20 deg C. Ambient Temprature - ) -5 deg C to + 40 deg C). Rated internal arc rating - 21KA for 1 Sec IAC- AFLR in Tank and cable box both. RMU, shall have manual operation. "Live Cable" LED indicators through capacitor voltage dividers mounted on the bushings. RMU, VCBs, LBSs, vacuum interrupter, VPIS, FPI & Numerical protection Relay etc. RMU cable box shall be only front accessible type to have easy access to protection and metering CTS. RMU shall be provided with protection CTs rated for 100/1 amps class - 10P10 accuracy, 2.5 VA burden for circuit breaker. Air circuit breaker feeders shall be self powered and provided with over current & earth fault protection for transformer and shall have serial port for communication on modbus protocol. RMU shall be provided with fault passage indicators in every feeder having LED indication and auto reset facility and one NO/NC auxiliary contact for showing status on SCADA. Note:- (i) Factory inspection & testing shall be carried by Rep of ACCEPTING OFFICER in factory premises. (ii) Contractor has to intimate/inform the dept well in advance before dispatching the material from factory premises. (iii) The cost of PCC Platform included in the quoted rates.
Supply, install , test and commissioning of 11 KV Outdoor 630 Amps (IP-54), SF6 gas filled with both side extensible Ring Main unit (RMU) mounted on PCC platform not less than 3 mtr x 1.5 mtr x0.6 mtr, manual operations and with internal copper bus bars. All live parts, bus bars., LBSs, VCBs connections of RMU should be enclosed in Stainless Steel tank of 2.5 +/-0.5 mm thick sealed for life having IP67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. RMU shall have solid earthing system. RMU should complete with all accessories such as Terminal boots, VPIS, FPI, cable supports, mechanical indications for load break switch ON/OFF, VCB ON/OFF, Spring charge, Manometer as per with IEC standards 62271-200. Internal arc type tested for 21KA for 1 sec. VCB/LBS used must be tested for minimum 00 nos of electrical operations in factory. Manufacturer has to submit valid test report. 1 No. incoming (LBSs) and 3 Nos. outgoing (VCBs). Rated voltage should be - 12KV. Rated power frequency voltage- 28KV. Rated lightining impulse withstand voltage - 75KV. Rated current for VCB feeder - 630 A. Rated short time current withstand - 21 KA for 3 Sec. Rated short time making current - 50 KA. Nominal operating gas pressure - 1.2 Bar abs. Ambient Temprature - ) -5 deg C to + 40 deg C). Rated internal arc rating - 21KA for 1 Sec IAC- AFLR in Tank and cable box both. RMU, shall have manual operation. "Live Cable" LED indicators through capacitor voltage dividers mounted on the bushings. RMU, VCBs, LBSs, vacuum interrupter, VPIS, FPI & Numerical protection Relay etc. RMU cable box shall be only front accessible type to have easy access to protection and metering CTS. RMU shall be provided with protection CTs rated for 100/1 amps class - 10P10 accuracy, 2.5 VA burden for circuit breaker. Air circuit breaker feeders shall be self powered and provided with over current & earth fault protection for transformer and shall have serial port for communication on modbus protocol. RMU shall be provided with fault passage indicators in every feeder having LED indication and auto reset facility and one NO/NC auxiliary contact for showing status on SCADA. Note:- (i) Factory inspection & testing shall be carried by Rep of ACCEPTING OFFICER in factory premises. (ii) Contractor has to intimate/inform the dept well in advance before dispatching the material from factory premises. (iii) The cost of PCC Platform included in the quoted rates
Supply instaling, testing and commissioning outdoor type, power transformer, 33 KV/11 KV, AC 3 phase 50 Hz 2 MVA capacity, core type double copper wound, oil immersed, naturally cooled, Oil Natural Air natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accodance with vector gorup Dyn-11 and having tapings at 5% & -15% in step of 1.25% each (17 steps) on HV side to be chaged by on load tap changer gear operating locally & remote. The maximum temperture rise shall not exeed 40 degree celsinus in oil and 55 degree celcius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature 50 degree celsius. Hot spot temperature rise over a Maximum yearly welghted tamperature of 32 degree C should be 98 degree C IS 2026 marked. with all accesssories and fitting as per IS 2026 CBIP. The core of transformer shall be bolt less to reduce hot spots and first grade CRGO sheets shall be used. The insulation level (impulse withstand in KV peak) shall be 170 on HV & 75 on LV side impulse level (power frequency with stand in KV runs) shall be 70 on HV and 28 on LV side. The percentage inpedance of the transormer at 75 degree C, rated curent of frequency should be 6.25 % (IS tolerance). The transformer shall be capable of withstanding thermal & dynamic effects circuit as specified in IEC 76-5 & fitted with the following:- (a) Three nos porcelain bushing suitable for 33 KV on HV side, complete with copper rods, nuts and washers & arching horns., (b) LV side shall be compatible with cable end box of suitable size., (c) Oil conservator with filter type drain valve and oil level gauge., (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers., (f) Oil temperature indicator dial of 150 mm with alarm and trip contact cappelary., (g) Two earthing terminals on tank cover to facilitate fixing of 50 x 6 mm galvanised iron earth strip for earthing of body.
(h) Rating plate and terminal marking plate with monograme., (j) First filling of new and unused transformer oil, IS-335 marked filtered and tested upto 60KV dielectric strength at 2.5 mm air gap between testing electrodes., (k) Magnetic oil level gauge with alarm and trip contact., (l) WTI (Winding temperature indicator) with alarm & trip contact HV and LV both side., (m) One no remote tap changer control panel (RTCC) with Automatic voltage controller (AVR)., (n) Marshling Box., (o) Buchholz relay with alarm & trip contact, (p) No load losses at rated voltage & FREQUENCY, kw 4.5 (Max)., (q) Load loss at rated current & 75 degree C, KW 31.0 (Max). (r) Noise level should not exceed 52 db. Note :- (i) Platform for transformer will be measured & paid for separately . (ii) Factory inspection & testing shall be carried by Rep of Accepting Officer in factory premises. (iii) Contractor has to intimate/inform the dept well in advance before dispatching the material from factory premises. Contractor will facilitate the inspection of transforme in manufacturer premises by the rep of Accepting Officer and will make all the necessary liason with manufacturer for the same.
Supply, erection, testing & commissiong of independent relay panel for 33KV transformer and feeder control for 33KV substation with having protective and auxiliary relay for protection of transformer and lines, indicating instruments with necessary switch, remote control for 33 KV circuit breaker, Alarm equipments, mimic panel, supervision equipments and complete wiring. Control & relay panel shall be fed 415/240 V 3 phase, 4 wires 50 HZ supply & DC supply at 24 Volts 2 wires & panel shall be complete cubical type floor mounted made of CRCA sheet 2mm thick complete and shall have the followingh protection relays :- (a) Transformer panel shall have Triple pole over currents relay IDMTL type with high set elements for over current protection a triple pole inverse definite miniumum time lag over currents relay with a setting range of 505- -200% (of 5 Amp rating) and fitted with high set elements of 500% -2000% of 5A for instantaneous clearance of faults within the transformer. (b) Line panel shall have triple pole combined over currents and earth fault relay consisting of outer two over currents elements having setting range 50% to 200% of 5 Amp having IDMTL charactristics and inner earth fault elements having setting range of 20-80% of 5 Amp having IDMTL characteristics shall be provided in each of the 33 KV line panel including panel shall be wired completely with PVC copper wire 2.5 Sqmm for CT & PT ckts and 1.5 Sqmm for control alarm, supervision circuits & fixing of panel in control room complete all as specified and directed.
Supply, installation testing and commissioning of Vacuum Circuit Breaker (VCB), indoor type, floor mounted, 11KV grade, 630 Amps single break trip free breaker with motor charging mechanism minimum breaking capacity 250, MVA, of draw out switch gear, complete with all HT accessories such as CTs protection device, indicating equipment for phases all as per IS-3402 and 12729 (VCB) and comprises the following :- CT DETAILS :- (I) 2 Core Epoxy cast type CT, CL I for metering and CL 5 P 10 for protection, 15 VA burden with ratio of 75- 50/5+5A - 3. BREAKER PANEL INDICATION LAMPS :- (I) Breaker on - 01. (ii) Breaker off - 01 (iii) Three phase indication - 03. (iv) Breaker TRIP - 01 (v) Trip circuit Healthy - 01 (vi) Spring Charged - 01. (vii) DC Control supply - 01. SWITCHES AND OTHER ACCESSORIES:- (i) TNC Switch (Non Lockable) - 01 (ii) Push Buttons - 01 (iii) Alarm Bell - 01 (iv) Heater with switch and thermostat - 01 (v) Anti pumping contactor - 01 (vi) 15A, 230V, pin plug and socket - 01 METERS:- (i) Tri vector meter - 01 (ii) Frequency meter- 01 (iii) Power factor meter - 01 (iv) A- Meter with S/S make enercon - 01 (v) V-Meter with S/S make Enercon - 01 RELAYS:- (i) 3 pole non directional IDMT relay, 2 O/C & 1 E/F element relay type CDG 31 or micom P 111-1 (ii) Auxilliary relay type VAA 11-2 (iii) Master trip relay type VAJH 13-1 PT Details (i) 11KV/110 Volts PT class 1 accuracy and 100 VA burden - 01 Nos
Supply erection testing and commissioning of 33 KV 630 Amps, 50 Hz isolator 3 pole single throw double break three posts per phase central pole rotating type manully operated. In a horizontal plane having pressure relieving type fixting contacts made of hard drawn electrvoltaic copper & switchblades forming the moving contacts shall be made from tubular section of hard drawn electrolytic copper having suitable dia and thickness and shall be silver plated each isolator shall be provided with bimetallic clamping type of connector suitable for ACSR 0.2 sq inch. including off indicator pad locking arragemets including having the following parameters and shall be fixed on existing steel structure:- (i) Nominal system voltage - 33 kV (ii) No of poles - 3 (iii) Rated voltage - 36 KV (iv) Continous currents - 630 Amp (v) Rated frequency 50 C/S HZ (vi) One minute power frequency withstand - 70 KV rms (vii) Impulse withstand voltage to earth and between poles - 70 KV (peak value) (viii) One minute power frequency test voltage - 100 KV rms (ix) Impulse withstand voltage across islating distance - 195 KV (peak value) (x) Phase clearance (Phase to phase) - 1220mm (xi) Short time current - 12.5 KV/1 Sec (xii) Rated peak short time current - 2.5 times the short time current
Supply installating testing & commissioning of current transformer, single phase oil filled self cooled outdoor type suitable for 3 phase 33 kV solidly earthed system complete as per IS -2705 (part -I,II,III & IV) or equivalent IEC shall have CT ratio 150-75/5/5/1Amp with primary current rating 150-75 Amp. Secondary currents rating 5/5/1 Amp for current metering & back up for O/C & E/F protection & including fixing of CT on existing steel structure with nut bolts etc complete as required & including first filling of oil complete all as specified and directed. Note:- The quoted rates includes the cost of first fill of new transformer oil,IS-335 marked filtered and tested upto 60 KV for dielectric strength.
Supply installation testing and commissining of potential transformer 33 KV single phase oil filled self cooled hermatically sealed outdoor type fixed on existing steel structure & suitable for highest system voltage 36 KV, 50Hz frequency rated primary voltage ratio 33/3, secondary voltage 110/3, solidly earthed, lighting impulse withstand voltage 170KV, min creepage distance of procelain housing 900mm, rated voltage factor 1.2 continous and 1.5 for 30 seconds & trempretatue rise as per IS 3156 or equivalent IEC complete in all respect and first filling of oil and complete testing complete all as specified and directed. Note:- The quoted rates includes the cost of first fill of new unused transformer oil,IS-335 marked filtered and tested upto 60 KV for dielectric strength.
M&L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts, bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specified and directed.
Supply, Erection, Testing and Commissioning of 11 KV 500 KVAR Capacitor bank with 0.2% reactor which is equivalent to 600 KVAR at 12.1KV, with 10% Over voltage.APFC Panel will comprising in 3-Steps with Electrical parameters KWH, KVAH, PF, HZ and ON, OFF, TRIP, FAULT,Suitable Ventilation and Temperature Indications.Capacitor Bank will be (IP-4X) in star configuration along with cast resin/resin impregnated air cooled series reactors, cast resin neutral CT in a closed container detailed as per technical specification and comprises the following :- Incoming:- (a) 11KV,400 Amp, 3Pole single break type off-load isolator with earth switch. - 01 No (b) 11KV, Indoor type Residual voltage transformer (RVT) with Resin cast, 3Phase, BIL-28/75KV.Ratio: 11KV/110-190V, Class:1,3Pole, Burden-100VA - 01 No (c) 11KV,0.1MFD,3Phase,RC-type -Surge Capacitor Unit - 01 No (d) APFC Relay -HT , 8-Step - 01 No (e) Digital type Ammeter & Voltmeter -Each- 01 No (f) R-Y-B Indications - 01 Set
Outgoing:- (a) 12.1 KV,300KVAR- Capacitor Bank - External Star (Each consist) - 01 No (i) Cap Unit -6.98KV ,100KVAR,1-Phase,CRCA, 2-bushing, BIL: 28/75KV - 03 Nos (ii) .2% Series Reactor- 1 Phase AL, Aircore type- 03 Nos (iii) Vaccume Contactor-11KV ,400A ,3P Solenoid type, 220V AC.- 01 No (iv) HRC Fuses- 12 KV- 03 Nos (b) 12.1 KV,150KVAR- Capacitor Bank -External Star (Each consist) -01 No (i) Cap Unit -6.98KV ,50KVAR,1-Phase,CRCA, 2-bushing, BIL: 28/75KV - 03 Nos (ii) .2% Series Reactor- 1 Phase AL, Aircore type - 03 Nos (iii) Vaccume Contactor-11KV ,400A ,3P Solenoid type, 220V AC. - 01 Nos (iv) HRC Fuses- 12 KV - 03 Nos (c) 12.1 KV,150KVAR- Capacitor Bank -External Star (Each consist) - 01 No (i) Cap Unit -6.98KV ,50KVAR,1-Phase,CRCA, 2-bushing, BIL: 28/75KV - 03 Nos (ii) .2% Series Reactor- 1 Phase AL, Aircore type - 03 Nos (iii) Vaccume Contactor-11KV ,400A ,3P Solenoid type, 220V AC.- 01 No (iv) HRC Fuses- 12 KV - 03 Nos Other Accessories (d) IP-4X CRCA enclosure with Non load bearing member-1.6mm, Load bearing member -2mm & Glant Plate -3mm.Paint shade-RAL 9003, Cable Entry- Top /Bottom.Doors( Front, side & Rear Access)- Bolted design doors with glass window - 01 No (e) EPOXY Insulator - 01 (f) NDR Relay(Unbalance Protection) - 01 No (g) Control wriring & accessories (MCB, AUX Contactor, Time Delay) with Auto Manual Switch, ON/ OFF Including Lamps & Push Button. - 01 No (h) Main Al Busbar- (50x6)mm Aluminium Busbar. - 01 Set (I) Interconnecting Busbar- (50x3)mm Aluminium Busbar. - 01 Set (j) Earthing Busbar- (25x3)mm Aluminium Busbar. - 01 Set
Material & Labour for Aluminium conductor, steel reinforced incl stringing in position complete all as specified and directed.
S&F LED Solar light 30 Watts with standard stand system for minimum 2 days autonomy with Polycrystaliline PV Panel, Solar tubular battery, battery box, GI tubular pole of suitable height as recommended by OEM and mechanical hardwares complete all as specified and directed by Engineer in Charge. Note:- Excavation/earth work, PCC will be measured and paid seperately.
M&L for Boaring of holes under road, pavment, hard standing by trenchless techlology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed. Note:-Quotated rate includes the cost of T&P required for boring the holes & pipe.
S & F HT 11 kV outdoor type gang operated air break switch Triple pole, Mechanically operated, mounted on insulator sand steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps complete all as specified & directed.
Supply & fix Disc type insulator, porcelain vitreous three in series ball & socket type for 33 KV working pressure complete all as specified & directed.
Supply istall and errect in true vertical position (or to be fixed in an inclined position as strut pole) Steel tublar swaged poles complete with MS base plate 6 mm thick of size 300 mmx3000mm, finial taper plug, pole cap, bolts, nuts and washers & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) HT pole including drilling of holes of required size and nos for fixing of cross arms, painting with one coat of red oxidezinc chrome primer and two coats of aluminium paint for exposed surfaces and two coats of black bitumen paint for portion embedded in concrete surfaces complete all as specified & directed. Note :- Excavation and earth work, PCC in foundation, pedstal & coping shall be measured and paid for separetely.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate for foundation of pole/struts/stay assembly etc complete all as specified & directed.
M&L for cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for pedestal of poles/coping including necessary formwork, fair finishing to exposed surface using extra cement complete all as specified & directed.
S & F expulsion fuse unit complete tyep of 65 kilo Amp discharge cap complete all as specified & directed.
M&L for lightning arrestors suitable for HT 11 KV, expulsion type, 30 kilo, discharge capacity including installing, testing & commissioning complete all as specified & directed.
M&L for earthing complete with galvanized steel earth plate electrode 60CM x 60CM x 6mm thick burled directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to metallic bodies of HT/LT equipments etc earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25x6mm flat iron clamps, bolts, nuts and washers and watering pipe shall be 20 mm bore medium grade including all excavation and earth work in any type of soil and removel of soil as directed, PCC pit with pre-cast RCC cover, charcoal/salt, funnel, GI frame etc complete all as specified and directed. NOTES (I) The concrete pit shall be made in PCC 1:3:6 type C-1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate with suitable handle in lieu of cast iron cover shown in electrical plate No 5 of MES SSR Part-I. Reinforcement in RCC cover shall be of 8mm dia TMT bars @ 150mm C/C both ways, (ii) Item includes the cost of 7.5m GI pipe for protection of earth wire/strip. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5m earth lead strip. Any variation in length shall be measured & paid under relevant item of the schedule. (iv) GI plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 150mm (minimum) on all sides.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & directed.
M&L for PCC 1:4:8 type D-2 in fdn filling and mass concrete complete all as specified & directed.
M&L for RCC M-25 for foundations, including rafts, footings, foundation beams plinth beams, bases for columns etc, basements slab, under-reamed piles & mass concrete complete all as specified & directed.
M&L for RCC M-25 for walls, retaining walls, basement walls ballast walls and the like,. Any thickness, above top of footings, including attached pilasters and buttresses complete all as specified & directed.
M&L for reinforced cement concrete type M25 design mix using 20mm graded broken stone aggregate as in slabs supported on walls, beams and columns in floors, foofs, landings, shelves and the like complete all as specified & directed.
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape requred, including creanking, binding spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with lips complete all as specified & directed.
All as per item No 40 but 5mm dia and over upto and including 10mm dia in stirrups, spacars and binders complete all as specified & directed.
M&L for formwork to side of concrete foundations, footings, based of colums, raft and raft beams sides and soffits (if any) of foundation and plinth beamsand similar work, vertical to better complete all as specified & directed.
M&L for formwork to face of walls, retaining walls, abutments, parapets & staircase railing & similar work including attached pilasters, buttresses, etc vertical or to batter complete all as specified & directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200m thick (Horizontal or sloping) complete all as specified & directed.
M&L 100mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in hardstanding/paving complete all as specified & direction by Eng-in-charge complete all as specified & directed.
M&L for rendering 5 mm thick in CM 1:3 over RCC surfaces complete all as specified & directed.
M&L for preparation of newly plastered surfaces on walls & applying three coats of white wash complete all as specified & directed.
M&L for Lightning arrestors suitable for HT 33 KV expulsion type, 65KA, discharge capacity including installing, testing & commissioning complete all as specified & directed.
M&L for anti-climbing device, spikes type, in two halves make to shape to suit the cross section of the poles, fabricated out of MS bars (round square and flat) welded to MS flat including nuts, bolts, washers etc complete all as specified & directed.
M&L for vice type connectors consisting of two brase plates and one bolt and nut for connecting two equal or unequal size of connectors for non tension connection incl treatment of connector and ACSR conductor with conductor Jelly complete all as specified & directed.
M&L for compression/crimpling type sleeves joints for jointing conductors/jumper connections including treatiment of joints with conducting jelly, upto 10mm dia of conductor wire over complete all as specified & directed.
Supply & fix pin type porecelain vitreous white, brown or green insutlator inclucing galvanized mild steel spindle, two galvanized iron washer and one galvanlzed nut for 33 KV volts AC supply grade complete all as specified & directed.
S&F GI earth Strip of size 32x6 mm buried in ground for extension of earthing electrode with suitable size nut, bolts & washers complete all as specified & directed.
S&F Rubberised insulating matting size 2000x1000x25 mm thick, heavy duty ISI marked & shall be of approved quality & make dully tested on 33 KV complete all as specified & directed.
S&F Rubberised insulating matting size 2000x1000x19 mm thick, heavy duty ISI marked & shall be of approved quality & make dully tested on 11 KV complete all as specified & directed.
Supply and fixing HT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with PCC complete all as specified and directed.
M&L for laying in trenches or on pole GI pipe light grade 80 mm dia for prortection of cable complete all as specified and as directed by Engineer in charge
M K ENGINEERS CO.
Pioneer Enterprises
PARAS BROTHERS
JAZZCON ENGINEERS PVT LTD
DUBEY TRADERS AND ENGINEERS
M M Brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .