| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Awarded as L1 bidder | |
| 2 | L2₹10.0 L+₹5.9 L (12.8%)Accepted-AOC P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Accepted-AOC Awarded as per MSME guidelines. | |
| 3 | Rejected-Technical 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | - | Rejected-Technical Origenal documents received after the stipulated time as mentioned in NIT. |
Tender Value
₹66.2 L
EMD Value
₹1.3 L
Closing Date
27 Aug 2019, 6:00 pmClosed
AGME E
NSCBI Airport Kolkata Airports Authority Of India
M O GLF at NSCBI Airport Kolkata dg 2019 20 SH Miscellaneous GLF works
2019_AAI_30286_1
AAC/EMD-II/GLF/2019-20
Open Tender
Electrical Works
Works
365 days
NSCBI Airport Kolkata Airports Authority Of India
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,120
Yes
Airports Authority Of India
₹1.3 L
Yes
29 Jul 2020
16 Aug 2019
2 Sept 2019
17 Aug 2019
27 Aug 2019
20 Aug 2019
17 Aug 2019 - 19 Aug 2019
Amount
Fabrication & supply of MS collar of size 330mm (L) x 330mm (W) and of suitable height as per site requirement (for increasing the height of the existing isolating transformer housing box) made out of 6mm thick MS sheet on four sides, 10mm thick MS sheet on top & bottom, with a provision of 50mm dia pipe entry hole on three sides, 225mm dia round opening on top & bottom with six nos threaded holes on edges of top & bottom plates, suitable for holding the taxiway/runway edge light fittings on top and bottom bolted to the existing box including painting the collar with one coat of primer & two coats of black enamel paint etc. complete as required & as per enclosed specifications.
Installation of MS collar (supplied against item no.1) by providing & fixing of 12 nos. 1½ inch M-10 SS bolts including minor civil works as per site requirement, making pedestal of not less than 0.30mt all around the box by making suitable slope by providing 1:2:4 cement concrete etc. complete as required & as per direction of Engineer-in-charge.
Dismantling of existing elevated light fittings and reinstallation of the same i/c connecting with isolating transformer etc. as required.
Dry brick pitching (laid flat) on surface including supply of bricks and preparing the surface complete as required.
Excavation of soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres .
Providing & laying in position 1:2:4 cement concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm. nominal size) over brick soling as per site requirement and as directed by engg.-in-charge.
Providing & laying 12mm thick cement plaster of mix 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement etc. as required.
Filling 2/3rd portion of old/discarded MS housing boxes with sand and remaining 1/3rd with cement concrete of ratio 1:2:4 finishing etc, as required as per site requirement.
Removing of existing broken bolt from the transformer housing boxes, making new holes by drilling, tapping etc. as required to match with M-10 bolt i/c supply and fixing of SS M-10 bolt, washer etc as required i/c hiring/arrangement of all necessary T&P like portable DG set, Drilling machine, Tapping machine etc. as required.
Providing cover plates of following sizes fabricated from 10mm thick MS plate, suitable for Isolating transformer housing boxes i/c making holes, drilling, tapping, finishing and fixing the same with 6 nos. 1.5" long, M-10 S.S. bolts, plain washers, spring washers etc. i/c painting etc. as required and as per direction of Engineer-in-charge. (a) 300 mm dia circular base plate
Providing cover plates of following sizes fabricated from 10mm thick MS plate, suitable for Isolating transformer housing boxes i/c making holes, drilling, tapping, finishing and fixing the same with 6 nos. 1.5" long, M-10 S.S. bolts, plain washers, spring washers etc. i/c painting etc. as required and as per direction of Engineer-in-charge. (b) 330 mm x 330 mm square base plate
Dismantling of C.I./M.S. transformer housing box from concrete foundation i/c disposal of debris etc. as reqd.
Fabrication & Supply of MS housing box of size 330 mm x 750 mm x 300 mm (H) made out of 6 mm thick MS sheet on four sides, 10 mm thick MS sheet on bottom, 10mm thick 25mm wide collars welded on top edges to hold the top cover plate and 280mm x 700mm rectangular opening on top & a 10mm thick, 330mmx750mm rectangular top cover plate with 12 nos. holes on the edges as per drawing enclosed along with 12 nos. M-10 size SS bolts for fixing of cover plate, with a provision of 90mm dia pipe entry hole on four sides, 15mm dia, 100mm long B class GI pipe with socket welded at bottom for drain, 2nos. SS earth bolts of M10 welded inside, painting of box with one coat of primer & two coats of black enamel paint, i/c providing rubber gaskets etc. complete as required and install the same in soil by providing brick soling (size 950mm x 530mm) at the bottom & using cement concrete of ratio 1:2:4 all around & bottom of the box of 100 mm thick and making pedestal of 300mm & 100mm thick all around the box by making suitable slope i/c centering & shuttering etc. as required and as per enclosed specifications.
Dismantling of 1 no. PVC/PILC insulated AFL cable of 5 KV grade of size not exceeding 25 sq.mm from soil i/c excavation, removing protective covering, refilling the trench etc.as required.
Laying of one no. PVC insulated & sheathed AFL cable of 5 KV grade of size not exceeding 25 sq.mm in the existing pipe.
Laying of one no. PVC insulated & sheathed AFL cable of 5 KV grade of size not exceeding 25 sq.mm in soil i/c excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Supply and laying of DWC HDPE pipe of 'Dura-line' or equivalent make of following size, by cutting soft soil upto 30cm, connecting both/one end to existing transformer housing box i/c refilling and making good the damages etc. as required. (a) 90/76 mm dia HDPE Pipe .
Supply and laying of DWC HDPE pipe of 'Dura-line' or equivalent make of following size, by cutting soft soil upto 30cm, connecting both/one end to existing transformer housing box i/c refilling and making good the damages etc. as required. (b) 63/51 mm dia HDPE Pipe.
Supply of Esna connector kit set suitable for 25sqmm, 5kV grade airfield lighting aluminium conductor cable as required and as per enclosed specifications. NOTE: - A set shall consist of one male and one female connector suitable for making connection of 25sqmm AFL cables.
Making connections of 5 KV grade, up to 25 Sq. mm Al conductor AFL cables with ESNA connector i/c crimping & fixing, applying HT tape complete as required.
Scrapping, cleaning the surface of existing LT Panels/feeder pillars and painting with two coats of synthetic enamel paint over a coat of red lead primer etc. as required.
Scrapping, cleaning etc. as required and painting the following light fittings with two coats of approved make Aviation Yellow synthetic enamel paint,over base plate said painting should be done after applying one coat of red lead primer. (a) Approach light fittings
Scrapping, cleaning etc. as required and painting the following light fittings with two coats of approved make Aviation Yellow synthetic enamel paint,over base plate said painting should be done after applying one coat of red lead primer. (b) Turn pad/taxi fittings
Scrapping, cleaning etc. as required and painting the following light fittings with two coats of approved make Aviation Yellow synthetic enamel paint,over base plate said painting should be done after applying one coat of red lead primer. (c) PAPI fixtures
Scrapping, cleaning etc. as required and painting the following light fittings with two coats of approved make Aviation Yellow synthetic enamel paint,over base plate said painting should be done after applying one coat of red lead primer. (d) Landing H
Scrapping, cleaning the surface of MS cover plates and exposed surface of MS boxes and painting with two coats of black colour synthetic enamel paint over a coat of red lead primer etc. as required.
Writing of maximum 2 inch size letters/numbers on the surface of base plates/cover plates of light fittings by ICI/ DECO or any other approved paint of white colour on a rectangular base painted with black colour as required.
Supply & installation of PAPI checking stick base suitable for AMA MK-III PAPI units i/c necessary minor civil works on the existing check stick base, cement plaster etc as required.
Supply of Safegate make LMS for Runway Guard light fittings (CAT No: LMS Dual; ver 5.2; 2x2 pol prog.; with switching capacity : 2x300watt; Current 2.5 - 6.6A ; Frequency 50Hz ; 45-50 Flashes/minute.
Supply of frangible tubular pole of following height confirming to ICAO Annex-14, para 5.3.1.4 and Aerodrome design manual part-IV, chapter 15, for mounting approach light fixture including all accessories such as base plate, anchore bolts, top brackets etc in single section or multi section depending on the height of the pole etc. as required. (The item shall comply ICAO / FAA Frangibility requirements. Test cerificate to be submitted for same.) (a) 2.00 mtr height
Supply of frangible tubular pole of following height confirming to ICAO Annex-14, para 5.3.1.4 and Aerodrome design manual part-IV, chapter 15, for mounting approach light fixture including all accessories such as base plate, anchore bolts, top brackets etc in single section or multi section depending on the height of the pole etc. as required. (The item shall comply ICAO / FAA Frangibility requirements. Test cerificate to be submitted for same.) (b) 1.69 mtr height
Supply of frangible tubular pole of following height confirming to ICAO Annex-14, para 5.3.1.4 and Aerodrome design manual part-IV, chapter 15, for mounting approach light fixture including all accessories such as base plate, anchore bolts, top brackets etc in single section or multi section depending on the height of the pole etc. as required. (The item shall comply ICAO / FAA Frangibility requirements. Test cerificate to be submitted for same.) (c) 1.25 mtr height
Supply of frangible tubular pole of following height confirming to ICAO Annex-14, para 5.3.1.4 and Aerodrome design manual part-IV, chapter 15, for mounting approach light fixture including all accessories such as base plate, anchore bolts, top brackets etc in single section or multi section depending on the height of the pole etc. as required. (The item shall comply ICAO / FAA Frangibility requirements. Test cerificate to be submitted for same.) (d) 1.95 mtr height
Supply of frangible lattice mast confirming to ICAO Annex-14 para 5.3.1.4 and aerodrome design manual part-IV, chapter 15, for mounting approach light fixture at the height mentioned below including all accessories such as foundation part, base frame, mast module, top frame, frame cross bar tube, light fitting, mounting arrangement etc complete as required. (The item shall comply ICAO / FAA Frangibility requirements. Test certificate to be submitted for same.) (a) Height 2.2 mtrs with Cross bar tube of length 3.30 mtrs.
Supply of frangible lattice mast confirming to ICAO Annex-14 para 5.3.1.4 and aerodrome design manual part-IV, chapter 15, for mounting approach light fixture at the height mentioned below including all accessories such as foundation part, base frame, mast module, top frame, frame cross bar tube, light fitting, mounting arrangement etc complete as required. (The item shall comply ICAO / FAA Frangibility requirements. Test certificate to be submitted for same.) (b) Height 3.20 mtrs with Cross bar tube of length 3.30 mtrs
Supply of frangible lattice mast confirming to ICAO Annex-14 para 5.3.1.4 and aerodrome design manual part-IV, chapter 15, for mounting approach light fixture at the height mentioned below including all accessories such as foundation part, base frame, mast module, top frame, frame cross bar tube, light fitting, mounting arrangement etc complete as required. (The item shall comply ICAO / FAA Frangibility requirements. Test certificate to be submitted for same.) (c) Height 4.5 mtrs with Cross bar tube of length 1.80 mtrs.
Installation of following frangible pole/mast along with accessories such as base plate, anchore bolts, top bracket, mounting of light fitting, making necessary secondary cable connections i/c removal of old/damaged mast etc. as required. (a) Frangible tubular poles
Installation of following frangible pole/mast along with accessories such as base plate, anchore bolts, top bracket, mounting of light fitting, making necessary secondary cable connections i/c removal of old/damaged mast etc. as required. (b) Frangible lattice masts
Dismantling of old/damaged earth pit chamber and reconstruction of the chamber by providing & making brick work, cement concrete etc., providing & fixing of MS frame of outer dimensions 330mm x 330mm, made out of 40x40x6 mm MS angle, with 8 nos. threaded holes suitable for M-10 SS bolts on the frame, with grouting arrangement in the brick work, providing 330mm x 330mm, 10mm thick MS cover plate with 8 nos holes on the MS plate, fixing of the plate on the frame with 8 nos. SS M-10 bolts including neat cement plaster around the MS frame etc. as required.
Fabrication & Supply of MS housing box of size 330 mm x 330 mm x 300 mm (H) made out of 6 mm thick MS sheet on four sides, 10 mm thick MS sheet on bottom & top, with a provision of 50mm dia pipe entry hole on four sides, 225mm dia round opening on top with six nos threaded holes on edges of top plate, suitable for holding the taxiway/runway edge light fittings on top including welding suitable MS handles made up of MS rod on two sides painting the box with one coat of primer & two coats of black enamel paint etc. complete as required & as per enclosed drawing.
Youngmen Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .