Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹16.2 L+₹200 (0.01%)Admitted-Finance 24 234 2 NEAR VYDHYUTHI BHAVAN KOTTAPPURAM ROAD PUNKUNNAM THRISSUR KERALA 680002 | THRISSUR | KERALA | 680002 | L2 | Admitted-Finance | |
| 3 | L3₹16.2 L+₹500 (0.03%)Admitted-Finance AFBA COMPLEX 17 577 E F PUTHIYARA ROAD CALICUT 673004 KERALA | CALICUT | KOZHIKODE | KERALA | 673004 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MICROTECHNOLOGIES L3 | MERKURY ELECTRICAL CORPORATION L2 | Sinelab Technologies Pvt. Ltd L1 |
|---|---|---|---|---|---|---|
| 1.00Civil Work | ||||||
| 1.01 | 2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil | 21 | cum | 215.37 ₹4,522.77 Lowest | 215.37 ₹4,522.77 Lowest | 215.37 ₹4,522.77 Lowest |
| 1.02 | 2 4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size) | 1.5 | cum | 6,857.61 ₹10,286.41 Lowest | 6,857.61 ₹10,286.41 Lowest | 6,857.61 ₹10,286.41 Lowest |
| 1.03 | 5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete | 54.6 | sqm | 337.42 ₹18,423.13 Lowest | 337.42 ₹18,423.13 Lowest | 337.42 ₹18,423.13 Lowest |
| 1.04 | 5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 419.58 | kg | 98.92 ₹41,504.85 Lowest | 98.92 ₹41,504.85 Lowest | 98.92 ₹41,504.85 Lowest |
| 1.05 | 5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse
sand :3 graded stone aggregate 20 mm nominal size | 7.82 | cum | 9,142.09 ₹71,518.57 Lowest | 9,142.09 ₹71,518.57 Lowest | 9,142.09 ₹71,518.57 Lowest |
| 1.06 | 13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 14.44 | sqm | 316.06 ₹4,563.27 Lowest | 316.06 ₹4,563.27 Lowest | 316.06 ₹4,563.27 Lowest |
| 1.07 | 2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m. | 13.04 | sqm | 260.19 ₹3,392.88 Lowest | 260.19 ₹3,392.88 Lowest | 260.19 ₹3,392.88 Lowest |
| 2.00Electrical Work | ||||||
| 2.01 | 90.15.1.1
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet
70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm
suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage
suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4
nos existing RCC foundation and junction box etc, complete 8 Meters | 15 | each | 29,831.21 ₹4,47,468.15 Lowest | 29,831.21 ₹4,47,468.15 Lowest | 29,831.21 ₹4,47,468.15 Lowest |
Tender Value
₹16.2 L
EMD Value
₹50,000
Closing Date
26 Aug 2025, 4:00 pmClosed
UNIT HEAD
KEL EDARIKODE
SITC of 8 Meter Minimast with 4 Nos 150 w LED Flood Light at Various Locations in Kottakkal LAC (Project No.20112) under MLA-ADS of Prof. Abid Hussainthangal Mla
2025_KEL_786119_2
KEL/ KEMG/39/2025
Open Tender
Electrical Works
Item Rate
180 days
KEL EDARIKODE
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
8 Sept 2025
19 Aug 2025
27 Aug 2025
19 Aug 2025
26 Aug 2025
19 Aug 2025
19 Aug 2025 - 26 Aug 2025
Amount
Civil Work
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Electrical Work
90.15.1.1 Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
Installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.9 Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
od347873/2023_2024 Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO Bettermann makes V25- B+ C/1+ NPE (switching/lightning protection) for single-phase protection.
od143058/2024_2025 Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
5.3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.16.4.2 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9.1.2 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as PRICE required.2 X 10 sq. mm (19mm)
Supply and fixing of 15 Nos of Name Board of MP with Angles ,Flats, Square Pipe, ACP Sheet (complete 4 sides) including Nut and bolt
Fabrication ,supply, conveyance and installation of 15 Nos of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc.
Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt).
MERKURY ELECTRICAL CORPORATION (BID ID -2308279)
MICROTECHNOLOGIES (BID ID -2305148)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .