Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.6 L+₹7,295.78 (0.77%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹9.9 L+₹35,750 (3.77%)Rejected-Finance | L3 | Rejected-Finance Highest |
Tender Value
₹10.0 L
EMD Value
₹25,100
Closing Date
18 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
Punargeham Project_Basic Infrastructure Facilities and Human Development of Fisher Folk Rehabilitation Scheme_Unniyal Malappuram_Electrification
2023_HED_571317_1
01/HEED/2023-24/e-T/S
Open Tender
Electrical Works
Item Rate
180 days
Unniyal Malappuram
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹25,100
13 Jul 2023
10 Apr 2023
20 Apr 2023
10 Apr 2023
18 Apr 2023
10 Apr 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 150 mm X 60 mm deep
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator(12 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 15652/2006
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 3-14W LED lamps including connection etc as required.
Providing and fixing 12 SWG insulated GI wire for service wire binding along with service line complete with all accesaries complete as required.
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supply of superior quality copper earth socket for the 6 SWG earth conductor including crimping etc. as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Providing and fixing 10.00 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 10 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Supply, conveyance, installation ,testing and commissioning of 20W LED Tube with fixtures 1200 mm Philips ,CG, hawells .
Supply of ceiling fan of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply and fixing 7/9 W LED, BC, lamp OSRAM or equivalent
Fabricating, supplying, erecting and commissioning of fully compartmentalised, dust and vermin proof cubicle type Metering panel board of size 1850x1500x250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over two coats of epoxy primer of approved quality, having front openable bolted type bus bar chamber & cable alley covers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top. The panel should have 75x40x6.0mm MS channel provided at the bottom as support and comprising the following(Panel drawing attached with the schedule). Incoming:- 63A 25kA FP MCCB setted to 50 A and rotory drive kit including BUC handle - 1No. Outgoing : 32A, 10 kA , DP MCB - 8Nos (through single phase enegymeter, cut out and neutral link). All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) ELR with CBCT current setting 0.03 A to 1A with delay time setting 0.3 to 3 sec - 1 No Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and bus bar is also to be carried out using25x3mm PVC insulated Copper strips supported using epoxy insulators as required. Provision for fixing eight numbers of single phase KSEB energymeter with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link in the panel should be made. Supply and providing 3 Nos of 63A Porcelain HRC fuse units with 40A HRC fuse link and 32A HRC fuse units with 25A HRC fuse link and 32A 2way neutral link in the eight single phase metering portion. The inter connection should be done using 10.00 sq.mm copper wire for single phase meter connection. Necessary holes are to be provided in the panel for entry and exit of wire. Metering and Indication:- 3Nos 50/5 A tape wound CTs,415V ac, 50Hz, 3LINE LED Multi Function Meter (Schneider or Equivalent)- 1 No.,22.5mm dia LED type indication lamps for three phases(R,Y &B) - 1 set and control Group B 2A SP MCB (C Curve)-6 numbers inside the cubicle. The panel board should have hinged shutters for MCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key arrangement and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3mm copper strip with two earthing points brought out at bottom side. (Panel drawing attached with the schedule)
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall40 mm dia nominal bore
SAJITHLAL K
Best Power Controls
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_843401.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .