Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹1.6 Cr+₹7.6 L (5.11%)Rejected-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹1.6 Cr+₹7.6 L (5.11%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.7 Cr+₹19.1 L (12.8%)Rejected-Finance C 17 UPPER GROUND FLOOR C BLOCK COMMUNITY CENTRE JANAK PURI JANAK PURI JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹1.7 Cr+₹19.1 L (12.8%) | L3 | Rejected-Finance Not Lowest |
| 4 | Not Admitted-Fee/PreQual/Technical 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.8 Cr
EMD Value
₹3.7 L
Closing Date
14 Jul 2022, 4:00 pmClosed
AGM(E-E)
JPNI Airport, Patna 1st Floor Electrical Department.
Annual Maintenance Contract of Electrical Mechanical Installations for Operational TB Area at J P N I Airport Patna For the year 2022 2024
2022_AAI_121176_1
AAI/ER/PAT/AGM(E-E) /AMC of Operational/e-NIT- 04/
Open Tender
AMC/ Maintenance Contracts
Item Rate
730 days
JPNI Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,120
Yes
₹3.7 L
Yes
22 Jul 2022
5 Jul 2022
15 Jul 2022
5 Jul 2022
14 Jul 2022
5 Jul 2022
5 Jul 2022 - 9 Jul 2022
Amount
Providing maintenance Services of Electrical and Mechanical Installations including Fire Alarm & Fire Hydrant System for Operational area ,Terminal Building, GLF Systems, lightings etc including MT Pool, Fire Station, Nav-Aid Buildings, Perimeter lights, Apron Flood lights, Elevator, EMD Offices, Office Areas etc. covering the scope of operation, preventive and breakdown maintenance, ensuring serviceability, satisfactory working condition of the system, preventive maintenance on daily, weekly, monthly, quarterly, half yearly and yearly basis, maintenance of records, documents etc. by engaging manpower round the clock basis and as per details mentioned in Special Condition of Contract.
For Period (Years 2022-24)
Rewinding of the following with Cu-winding wires of required size including less for dismantled copper wire etc. as reqd. etc. as required (Dismantle cu-wire need not to return).
Ceiling fans (1200mm/1400mm)
Exhaust fans 450 mm
Exhaust fans (225mm/300 mm)
wall fans/pedestal fans upto 450mm
Replacement of bearing for above fans
Lifting, repairing and lowering upto 2 H.P. submersible pump motor set i/c column pipe, cable, jointing of submersible cable and sealing of pump motor with sealant material, testing commissioning etc complete as reqd.
Rewinding of burnt motor of submersible pump motor set upto 2 HP with suitable size of Cu-winding wires including sealing of pump motor with sealant material, testing etc. as required. ( Burnt Cu Wire need not to return )
Rubbing, cleaning & painting of feeder pillars/ electrical Panels/DBs/Fire Hydrant Boxes etc with one coat of red oxide and one or more coat of high gloss synthetic enamel paint of any colour as approved by Engineer-in-charge .etc. complete as reqd.
Painting of electrical Runway/Taxi/Approach light fittings including base plate with two coats of synthetic enamelled paint of approved make in yellow colour to give an even shade including numbering of fittings in black colour etc complete as required.
All inclusive Comprehensive maintenance upto length 5 feet Air-curtain available at different location of Terminal Building i/c replacement of required accessories such as bearing, bushes, fan blades etc. with rewinding of fan motors, servicing & cleaning of all air-curtains once in a month, testing, making ensure serviceability all the time etc complete as required.
For 1st Year (Yr. 2022-23)
For 2nd Year (Yr. 2023-24)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connections, from earth electrode with 6SWG dia, G.I wire in 15mm dia G.I pipe from earth electrode as required.
Providing and fixing 6 SWG dia G.I. wire along with UG cable in HDPE/GI/DWC Pipe etc complete as required.
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module
6 Module
Laying of 1 no. PVC insulated and PVC sheathed stranded copper conductor airfield lighting cable of grade exceeding 1.1 KV but not exceeding 5 KV of size not exceeding 16 sqmm in the existing masonary open duct/pipe etc as required.
Supply of one packet (25 kg) fosroc Conbextra GP2 Compound for filled up gap for inset fitting on runway.
Supply and fixing 20 amps, 240 volts, SPN industrial Modular type, socket outlet with plug top along with 20 amps “C” curve, SP MCB, in sheet steel enclosure, on surface or in recess with connections, testing and commissioning etc. as required.
Excavation for cable trenches in soft soil, depth upto 1.2 m including refilling of soil, dressing of sides i/c ramming, watering and getting out of disposal of surplus excavated soil as directed, within a lead of 50 metres.
ABHISHEK INTEGRATIONS LIMITED
S. N. ELECTRIC & MAINTENANCE PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .