Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC C 234 ADG P CHENNAI | ₹1.2 Cr | L1 | Accepted-AOC being L1 |
| 2 | L2₹1.2 Cr+₹1.6 L (1.41%)Rejected-AOC AMBADI NEAR PAACHAKKIL BUS STOP MALAPARAMBA POST KOZHIKODE DISTT KERALA 673 009 | KOZHIKODE | KOZHIKODE | KERALA | 673009 | ₹1.2 Cr+₹1.6 L (1.41%) | L2 | Rejected-AOC rejected being L2 |
| 3 | L3₹1.2 Cr+₹7.3 L (6.22%)Rejected-AOC LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | ₹1.2 Cr+₹7.3 L (6.22%) | L3 | Rejected-AOC rejected being L3 |
| 4 | L4₹1.3 Cr+₹13.1 L (11.2%)Rejected-AOC DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | ₹1.3 Cr+₹13.1 L (11.2%) | L4 | Rejected-AOC rejected being L4 |
| Sl No | Description | Qty | Unit | LEKSHMI ENGINEERS L3 | KDR CONSTRUCTION L4 | GMS Builders L1 | EXCEL ENGINEERING L2 |
|---|---|---|---|---|---|---|---|
| 0.00Notes for all item :- (i) The entire scope of work shall be carried out from ground level to nearly upto 50 metres of height in a scattered location. (ii) The work shall be carried out on vertical surfaces, flat RCC roof, sloped mangalore roof and sloped galvalume sheet with slope varying from 1:1 to 1:0.5 . (iii) Quoted rates are deemed to be inclusive for boom lift/crane as required. Contractors should arrange boomlift/crane and takes all safety precautions for workers including accidental coverage insurance for workmen employed. (iv) Quated rate included for any other T&P required to complete the work and no extra claim will be entertained. (v) Scaffolding shall be set up to carry out the work where the boomlift are not approachable near the building due to the terrain/design criteria, | |||||||
| 1.00 | Dismantling plain or corrugated steel sheeting / galvalume sheet any gauge, thickness as in roof covering complete all as specified and directed. | 3,374 | Square Metre | 68 ₹2,29,432 | 25 ₹84,350 Lowest | 50 ₹1,68,700 | 50 ₹1,68,700 |
| 2.00 | S& F 0.50 mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. | 3,474 | Square Metre | 990 ₹34,39,260 | 950 ₹33,00,300 Lowest | 950 ₹33,00,300 Lowest | 1,100 ₹38,21,400 |
| 3.00 | S& F 0.5 mm thick Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,ridge etc fixed with self tapping screws , rivetting with existing roof sheets/ valley gutters, bolting on to parepat walls etc complete all as specified and as directed. | 567 | Square Metre | 970 ₹5,49,990 | 845 ₹4,79,115 Lowest | 850 ₹4,81,950 | 1,000 ₹5,67,000 |
| 4.00 | Taking down existing water proofing treatment of any description over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface (by mechanical means like grinder, etc) and removal rubbish off the premises complete all as specified and as directed. | 658 | Square Metre | 68 ₹44,744 | 101 ₹66,458 | 50 ₹32,900 Lowest | 75 ₹49,350 |
| 5.00 | Demolition of cement concrete (un-reinforced) as in roof slab padding n exc 15 cm thickness in any position complete all as specified and as directed. | 32.9 | Cubic Metre | 520 ₹17,108 | 1,000 ₹32,900 | 200 ₹6,580 Lowest | 1,000 ₹32,900 |
| 6.00 | M&L for cement concrete 1:2:4, type B1 (12.5 mm graded stone aggregate) as in filling and mass concrete, roof slab padding preparatory to roof treatment complete all as specified and as directed. | 35.25 | Cubic Metre | 9,100 ₹3,20,775 | 9,000 ₹3,17,250 Lowest | 10,000 ₹3,52,500 | 10,000 ₹3,52,500 |
| 7.00 | M&L for water proofing treatment to roof surface with APP polymeric based water proofing membrane 3mm thick & weighing not less than 3.5 Kg/Sqm of approved make black finish consisting of a central core of high molecular high density polyethylene film (HMHDPF) & reinforced with non woven polyester matt of min 150 gm/sqm with a thermo fusible finish laid over a coat of hot blown bitumen of 85/25 grade conforming to IS 702 @ 1.2 kg/sqm over a coat of an bitumen primer conforming to IS-3384 @0.4 Ltr/Sqm over prepared roof surfaces, forcing overlap with a propane or butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing incl applying a coat of cold emulsion bituminous primer and including 10mm thick rendering in CM 1:3 on roof with water proofing compound, surfaces finished even and smooth without using extra cement complete all as per manufacturer's instructions complete all as specified and as directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same manufacturer.
3. The APP Membrane to be inserted in the parapet wall/wall by cutting chases of atleast 65mm X 50mm size & making good in CM 1:3. | 658 | Square Metre | 745 ₹4,90,210 | 990 ₹6,51,420 | 500 ₹3,29,000 Lowest | 800 ₹5,26,400 |
| 8.00 | Dismantling wall and ceiling boards of aluminium metal planks or insulation boards/slabs/blankets any thickness and specification with cover fillets and including aluminium snap grid frame work, carrier span and hangers all as specified and directed. | 342 | Square Metre | 28 ₹9,576 | 15 ₹5,130 Lowest | 50 ₹17,100 | 40 ₹13,680 |
| 9.00 | S&F Anodised aluminium snap grid frame work for false ceiling all as specified The snap grid frame work shall be fixed to ceiling with hangers 6 mm dia. G.I. (upto roof/truss height) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. Note ; Minimum average thickness of anodizing (coating of anodizing) on all aluminum section and fitting shall be 15 micron | 162 | Square Metre | 565 ₹91,530 | 800 ₹1,29,600 | 600 ₹97,200 | 450 ₹72,900 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
7 Jun 2025, 6:00 pmClosed
CWE Ezhimala
CWE Ezhimala Indian Naval Academy PO 670310
As per BOQ and tender documents
2025_MES_707402_1
80495
Open Tender
Civil Works
Item Rate
270 days
Ezhimala
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE (Maint) Ezhimala
₹2.4 L
Yes
6 Aug 2025
9 May 2025
12 Jun 2025
10 May 2025
7 Jun 2025
24 May 2025
10 May 2025 - 17 May 2025
Amount
Notes for all item :- (i) The entire scope of work shall be carried out from ground level to nearly upto 50 metres of height in a scattered location. (ii) The work shall be carried out on vertical surfaces, flat RCC roof, sloped mangalore roof and sloped galvalume sheet with slope varying from 1:1 to 1:0.5 . (iii) Quoted rates are deemed to be inclusive for boom lift/crane as required. Contractors should arrange boomlift/crane and takes all safety precautions for workers including accidental coverage insurance for workmen employed. (iv) Quated rate included for any other T&P required to complete the work and no extra claim will be entertained. (v) Scaffolding shall be set up to carry out the work where the boomlift are not approachable near the building due to the terrain/design criteria,
Dismantling plain or corrugated steel sheeting / galvalume sheet any gauge, thickness as in roof covering complete all as specified and directed.
S& F 0.50 mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
S& F 0.5 mm thick Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,ridge etc fixed with self tapping screws , rivetting with existing roof sheets/ valley gutters, bolting on to parepat walls etc complete all as specified and as directed.
Taking down existing water proofing treatment of any description over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface (by mechanical means like grinder, etc) and removal rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) as in roof slab padding n exc 15 cm thickness in any position complete all as specified and as directed.
M&L for cement concrete 1:2:4, type B1 (12.5 mm graded stone aggregate) as in filling and mass concrete, roof slab padding preparatory to roof treatment complete all as specified and as directed.
M&L for water proofing treatment to roof surface with APP polymeric based water proofing membrane 3mm thick & weighing not less than 3.5 Kg/Sqm of approved make black finish consisting of a central core of high molecular high density polyethylene film (HMHDPF) & reinforced with non woven polyester matt of min 150 gm/sqm with a thermo fusible finish laid over a coat of hot blown bitumen of 85/25 grade conforming to IS 702 @ 1.2 kg/sqm over a coat of an bitumen primer conforming to IS-3384 @0.4 Ltr/Sqm over prepared roof surfaces, forcing overlap with a propane or butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing incl applying a coat of cold emulsion bituminous primer and including 10mm thick rendering in CM 1:3 on roof with water proofing compound, surfaces finished even and smooth without using extra cement complete all as per manufacturer's instructions complete all as specified and as directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same manufacturer. 3. The APP Membrane to be inserted in the parapet wall/wall by cutting chases of atleast 65mm X 50mm size & making good in CM 1:3.
Dismantling wall and ceiling boards of aluminium metal planks or insulation boards/slabs/blankets any thickness and specification with cover fillets and including aluminium snap grid frame work, carrier span and hangers all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling all as specified The snap grid frame work shall be fixed to ceiling with hangers 6 mm dia. G.I. (upto roof/truss height) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. Note ; Minimum average thickness of anodizing (coating of anodizing) on all aluminum section and fitting shall be 15 micron
M&L for 4mm thick non-asbestos fiber cement building boards fixed or laid/inserted to aluminium framework complete all as specified and as directed.
M&L for providing pre painted polyester coated aluminium alloy, glossy finish, 3mm thickness, 50micron coating (metal planks) for false ceiling including provision of suitable carrier span and hangers as per manufacturers instructions complete all as specified and as directed.
All as per item ser No 11 above but except sheet complete all as specified and as directed.
Dismantling of existing sadarahally stone of any thickness from vertical cladding/fixed on wall, horizontally or in slope complete including nut and bolts all as specified and as directed.
S&F 20 to 25 mm thick flame finished sadarahally machine cut stone cladding fixed with stainless steel clamp and anchor fasteners Hilti make stainless steel anchor fastners one set consists stainless steel anchor fastner- 10 x 80mm, stainless steel anchor fastner- 10 x 150 mm and stainless steel clamp 5 x 50 mm on vertical surface of wall and column. Following precautions shall be taken before fixing stone cladding. a) Suitable depression (approx. 5mm width and 25 mm depth on vertical face) shall be made to fix the stainless steel clamp. b) Suitable drill hole to the surface of stone and wall/column to fix shall be made to fix anchor fasteners. c) Make good the surface of drilled portion (where headless bolts are inserted) using universal surface filler(supertak or equivalent). Note : 1. Quated rates are included for the cost of Scaffolding/Boom lift/Crane as required and all safety precautions for workers at the time of carrying out works as described 2. Cost of Hilti make anchor Fasteners, clamps and headless bolts shall be measured and paid separately.
All as per item No. 14 above but except Sadarahally stone complete all as specified and as directed.
Supply only Hilti make stainless steel anchor fastner- 10 x 80mm, stainless steel anchor fastner- 10 x 150 mm and stainless steel clamp 5 x 50 mm for fixing of sadrahally stone cladding complete all as specified and as directed.
Dismantling plain polycarbonate sheet any gauge, thickness from roof including frame work complete all as specified and as directed.
S&F transperent polycarbonate roofing sheet 4mm thick fixed with aluminium frame work etc complete all as specified and as directed. Note: Aluminium frame work shall be measured and paid separately.
M&L for anodised aluminium section as frame work for fixing polycarbonate sheets including joining cleat for fixing etc. complete all as specified and directed. Note ; Minimum average thickness of anodizing (coating of anodizing) on all aluminum section and fitting shall be 15 micron
Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed.
M&L roof tiles Mangalore pattern, class 'AA' interlocking at side joints, laid dry complete all as specified and as directed.
All as per item No 21 here above but except tiles complete all as specified and as directed.
M&L for Mangalore pattern ceiling tiles, laid dry complete all as specified and as directed.
All as per item No 23 here above but except tiles complete all as specified and as directed.
M&L, ridge or hip tiles to suit Mangalore pattern or roofing tiles bedded and jointed in cement mortar 1:6 using water proofing Compound complete all as specified and as directed.
M&L Preparation of new MP roof tile surfaces by and applying two coats of antifungal paint over a coat of primer complete all as specified and as directed.
M&L Preparation of old MP roof tile surfaces by scrapping and cleaning the tiles and applying one coats of antifungal paint complete all as specified and as directed.
Dismantling plain, black, mild steel sheeting upto 4mm thick in ridges, hips, valley gutters, drip and straight flashings complete all as specified and as directed.
M&L for plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings length and girth including moulding according to existing shape and size of gutter and necessary welding etc complete all as specified and as directed.
Dismantling aluminum composite panel fixed on aluminium frame work of any shape and size complete all as specified and as directed.
S&F Aluminium Composite Panel 4mm thick of any colour and shade of Alu Bond or equivalent fixed with self tapping existing screws on aluminium frame work of any shape and size and filling all joints as per manufactures instructions complete all as specified and as directed.
All as per item no 31 above but except aluminium composite panel complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for Note:- All dismantled materials shall be removed from site without any delay and shall be stacked at places where Engineer in Charge directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe- 290 (Gde E-165) complete all as specified and as directed..
S&F MS steel work in tubular sections (Circular/Square/Rectangular) as in post, trusses, brackets, purlins, rafters etc., conforming to IS 1161-1998 grade St-240 for hollow tubes including necessary welding etc complete all as specified and as directed.
S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted (anchor fastner) or welded attachment (Fe-410W, Gde E-250, Qlty-B) including necessary cutting in wall complete all as specified and as directed.
Taking down of cement plaster of any description or thickness/chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to received new plaster complete all as specified and as directed.
M & L for 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L, 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces with liquid water proofing compound, surface finished even and fair, complete all as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately
M&L for sealing of screw holes in roofing sheets with PU sealent of Make : Forsroc, McCoy Soudal or equivalent including cleaning of existing surfaces complete all as specified and as directed.
M&L for sealing all the joints in sadharly stone with epoxi sealent of Make : Forsroc, McCoy Soudal or equivalent including cleaning of existing surfaces complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old painted steel/iron surfaces over 10cm width or girth and applying one coat of synthetic enamel paint on complete all as specified and as directed.
Treating of cracks by creating V grooves as per specified and filling the same with joint filling compound and mantching with the adjecent surfaces complete all as specified and as directed.
S & F PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Supply only liquid waterproofing compund.
M&L for preperation of new plastered surfaces and applying two coat of acrylic emulsion paint (interior grade) on wall over a coat of acrylic primer all as specified and as per manufacturers instructions.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old/new surfaces complete all as specified and as directed.
M&L Cutting channels, grooves or rebates With or without reinforcement n.exc 15cm girth, trimming surface for plane sheet and filling the gap with joint filling material complete all as specified and as directed.
M&L Laying and pasting of Bituminous strip of width 10 cm of Make : 3M, BASF, Dr.Fixit, Forsroc or equivalent on joints of galvalume sheet & RCC surfaces including cleaning of existing surfaces complete all as specified and as directed.
M & L for applying two coat of polyurethane liquid or silicone based water repellant repellin WR of Pedilite or equivalent for water proofing treatment before plastering on walls complete all as specified and as directed.
Disconnecting existing tanks setting aside (or lowering if required) overhead PVC water tank of capacity 500 ltr including re-fixing in position after completion of roof treatment including all fittings ( GI connection, tank nipple etc) complete all as specified and directed. overhead PVC water tank of capacity 500ltr including re-fixing in position including all fittings( GI connection, tank nipple etc) complete all as specified and directed.
All as per item No.52 above but 1000 ltr capacity complete all as specified and directed.
Dismantling of existing water tank of capacity 500 ltrs including fittings lowering and removing to store all as directed.
All as per item No.54 above but 1000 ltr capacity all as directed.
S&F rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as speciifed in SSR Part I of capacity 500 ltrs with ball brass valves, high pressure, with polythene float and flynut bore dia of pipe 25 mm complete screwed for iron pipe or brass ferrule and fixedwith existing dia of pipe complete all as specified and directed.
All as per item No.56 above but 1000 ltr capacity complete all as specified and directed.
Removal of Vegetation from wall and roof by cutting shrubs, wild growth/tree not exc 30cm girth and removing complete vegetation growth from walls including taking out roots from roof/ walls and making good the disturbed surface with PCC 1:2:4 type B-0 or CM 1:3 as directed by Engr-in-charge and disposing the rubbish from site complete all as specified and directed.
S&F stailess steel roof drain grating for efficient rain water drainage size 150mmx150mm square design fixed on rain water pipe at roof complete all as aspecified and directed.
M&L for sealing of polycarbonate roofing sheets joints with PU sealent of Make : Forsroc, McCoy Soudal or equivalent including cleaning of existing surfaces complete all as specified and as directed.
Dismantling Luxalon 84R Hi mirror false ceiling system consisting of panel 84mm wide x 16 mm deep made out aluminium at a height approximately 25M from the ground level at foyer of AMBC Nalandha Bldg all as specified and directed by Engineer- in- Charge.
S&F Luxalon 84R Hi mirror false ceiling system consisting of panel 84mm wide x 16 mm deep made out of 0.5mm thick anodised aluminium of chrome finish. The panel should be chipped to a baked enameled aluminium panel carrier made out of 0.95mm thick already fixed at a height more than 25m from floor level complete all as specified and directed.
All as per item No 62 here above but except ceiling panel complete all as specified and directed.
S&F in repairs GI suspension rod of 4mm dia where ever required to support the panel carriers suspended from ceiling for fixing the false ceiling at foyer of Nalanda Bldg at AMBC as required and directed by Engineer in charge complete all as specified and directed.
S & F PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
M&L for application of two coats of TankMastic bituminous Anti-corrosive Multi-purpose coating Make STP Ltd or equivalent on corrosive portion of MS sheet valley gutter as per manufacturer instruction complete all as specified and directed. Application Methodology (a) Surface Preparation - The surface shall be cleaned thoroughly of all contaminants like dust, traces of curing compound, oil and grease. All surface imperfections and protrusions shall be removed and repaired. (b) Material Preparation - Stir TankMastic thoroughly before use to make it homogeneous. After stirring, wait for the product to settle in order to let entrapped air escape. (c) Application of Material - Apply TankMastic as supplied on the prepared surface by brush / roller / spray. Repeated coats shall be given only after the earlier coat dries completely minimum 12 to 16 hrs after 1st coat.
M&L point wiring complete with FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size, concealed / semi concealed / open with necessary fixing accessories such as bend, elbow, socket etc with fixing material and including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including taking down the old point wiring with fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of walls, floor ceiling etc. complete all as specified for the following :- (a) One Light/fan/bell point controlled by one switch . Note : (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in Charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Note : (a) wiring shall be done by using colour code ie. Red, Yellow, Blue and earth wire shall be green colour. (b) quoted rate included cutting chases for fixing conduit.
All as per item No. 67 here in before but for one 3 pin 15 amp socket on independent board with 2.5Sqmm unsheathed PVC insulated copper conductor FRLS cable including 2.5 Sqmm PVC insulated copper cable for earth continuity conductor complete all as specified.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body all as specified and directed by Engineer in Charge.
S&F modular switch one way 6 Amps, 1 module including connecting up electrically complete all as specified and directed. Make : Legrand /Crabtree.
S&F modular socket 6 Amps /16 Amps, 3 pin 2 module multipurpose including connecting up electrically complete all as specified and directed.. Male : Legrand/Crabtree.
S&F modular switch one way 16 Amps 1 way, 1 moduleincluding connecting up electrically complete all as specified and directed.. Male : Legrand/Crabtree.
M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amps complete all as specified and directed.
M&L sub main wiring using 2 runs of 1.5 sqmm FR PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through existing concealed/open conduit along with 1 run of 1.5 Sqmm PVC insulated copper condutor FR cable as earth lead connected to common earth dolly complete all as specified including taking down the unserviceable wiring. Note : 3 runs of 1.5 sqmm PVC insulated copper conductor in existing conduit will be measured as one unit.
All as per item No 74 above but 4.0 sqmm FR PVC insulated copper conductor drawn through existing PVC conduit complete all as specified including taking down the unserviceable wiring..
S&F modular type metal box including white modular cover plates with frame for one module all as specified and directed.
S&F modular type metal box including white modular cover plates with frame for three module all as specified and directed.
S&F modular type metal box including white modular cover plates with frame for four module all as specified and directed.
S&F modular type metal box including white modular cover plates with frame for six module all as specified and directed.
Supply and fixing in repair LED light fittings 1x 20W, 220V, AC, decorative box type with driver holder including LED tube light internally prewired and including connecting up with twin core twisted copper flexible conductor cable of sutibale size all as directed.
Supply and fixing in repair Recess mounting Scintilate LED round slim Panel 22 W powder coated PDC aluminium body & high quality PGP & PMMA diffuser, driver complete all as specified and directed.
S&F LED light fitting1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Schedule of Credit (Minus) Rs.158510.00 NOTE: Bidder shall insert credit amount of Rs. 158510.00 as rate in Green field under Col-5.
EXCEL ENGINEERING (BID ID -3316470)
LEKSHMI ENGINEERS (BID ID -3305469)
KDR CONSTRUCTION (BID ID -3309109)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .