Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.3 Cr+₹18.4 L (16.5%)Rejected-Finance HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | PANCHKULA | HARYANA | 134118 | ₹1.3 Cr+₹18.4 L (16.5%) | L2 | Rejected-Finance Highest |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
8 Sept 2021, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of State Archaeological Museums, Sec.-5, Panchkula. (Pdg. E.I Only).
2021_HRY_185095_1
PWD/Elect-KNL/Elect-AMB/110181
Open Tender
Construction Works
Works
365 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2.4 L
11 Mar 2022
26 Aug 2021
9 Sept 2021
26 Aug 2021
8 Sept 2021
26 Aug 2021
Amount
CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. 48" (1200mm) HSR No. 20.71.1
Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge HSR No. 20.72
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C HSR No. 23.2.1.3
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C HSR No. 23.2.2.3
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C HSR No. 23.2.5.3
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data HSR No. 23.8.10.1
6 Modules HSR No. 23.8.10.4
12 Modules HSR No. 23.8.10.6
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR No. 23.8.11.1
15 amp 1 way switch HSR No. 23.8.11.3
5 amp Socket HSR No. 23.8.11.4
15 amp 6 pin Socket HSR No. 23.8.11.5
Step type Fan Regulator 2 modules 300 watt HSR No. 23.8.11.7
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp HSR No. 23.22.1.9
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.5
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) HSR No. 23.22.4.7
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
40 amp to 63 amp. MCB's FOUR POLE HSR No. 23.22.5.8
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. HSR No. 23.24.1
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR No. 24.1.3
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR No. 24.1.5
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR No. 24.1.7
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 24.1.8
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. HSR No. 24.1.13
Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR No. 24.2.4.3
Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core HSR No. 24.2.7.3
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm HSR No. 24.2.8.7
Compact Air Insulated Rising Main Supply, Installation, Commissioning, Testing of Air insulated compact Rising Main having enclosure made up of 1.6mm thick Electro Galvanised G.I sheet duly powder coated, 4 P Aluminium Bus Bar in convenient sections with support of F-Insulators at suitable distance, suitable for 415 Volt, 50 Hz AC, including fire barriers, vertical brackets, end cover and 2 runs of external Aluminium earhting to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of Work. 400A/30KA NS-1 i)
630A/50KA NS-1 ii)
End Feed Unit (for Compact Air Insulated Rising Main) 400 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-2 i)
630 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-2 ii)
Plug-in-Box (for Compact Air Insulated Rising Main) 63 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-3 i)
100 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-3 ii)
125 Amp. with MCCB, Extended Rotary handle and Spreader Link NS-3 iii)
Supply of aluminium armoured cable of size 50 Sq. mm 3.5 Core, Make as per approved list. NS-4
Supply & Erection of 16 Sqmm x 4 Core PVC insulated and PVC round sheathed copper conductor flexible industrial cable 1100 Volt with the help of all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. Make as per approved list. NS-5
Supply & Erection of 25 Sqmm x 4 Core PVC insulated and PVC round sheathed copper conductor flexible industrial cable 1100 Volt with the help of all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. Make as per approved list. NS-6
M/S GARG ELECTRICAL
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .