Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹3.8 LAccepted-AOC COLONEL BHAWAN VILL PO JAIHARIKHAL VIA LANSDOWNE DIST PAURI GARHWAL UK PIN 246193 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246193 | ₹3.8 L | 1st | Accepted-AOC Lowest |
| 2 | 2nd₹4.5 L+₹74,667.80 (19.7%)Rejected-Finance | ₹4.5 L+₹74,667.80 (19.7%) | 2nd | Rejected-Finance L2 |
| 3 | 3rd₹4.6 L+₹79,577.80 (21.0%)Rejected-Finance GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹4.6 L+₹79,577.80 (21.0%) | 3rd | Rejected-Finance L3 |
Tender Value
₹6.3 L
EMD Value
₹12,540
Closing Date
13 Jul 2023, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
PROVN OF GARBAGE BINS ENTRY GATE AND TOP ROOF IN EXISTING GARBAGE BIN PROTECTION AT VARIOUS LOC AT GRRC AND PROVN OF GARBAGE PIT AT ORs FAFA ACCN AT LANSDOWNE UNDER AGE I LANSDOWNE
2023_MES_602726_1
8833/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Lansdowne
Class E Cat a i
8 documents required · 8 mandatory
₹500
AGE I Lansdowne
₹12,540
7 Aug 2023
12 Jun 2023
20 Jul 2023
12 Jun 2023
13 Jul 2023
26 Jun 2023
Amount
M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering , doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening Complete all as specfied and directed.
Excavation in trenches,not exceeding 1.5 M wide and not exceeding 1.5 M depth; for foundation etc and getting out in soft/disintegrated rock Complete all as specfied and directed.
Removing of excavated soil n exc 50m and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
M&L for prepration of new steel surface and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and directed.
M&L Plain Cement Concrete type C-2, 1:3:6 (using 40 mm graded stone agg) in foundations, filling and mass concrete complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
S&F Joist, channel, angle, tee/flat or other sections, including cutting tops to shapes as directed drilling holes ,notching for wire etc and simillar work conforming to Fe 290 Gde-E-165 etc Complete all as specfied and directed.
Returning filling in with approved excavated earth, incl spreading leveling, watering and well ramming in layers n exc 25 cm thick with soft/disintegrated rock complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Providing, cement concrete in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles as specified and directed.
M&L for 100 mm thick Plain Cement concrete Type - B-2 (1:2:4) (using 40 mm graded stone aggregate) in floors finished smooth complete all as specified and directed.
M&L for Surface excavation in soft/disintegrated rock n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for providing 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement Complete all as specfied and directed.
M&L preparing new plastered surfaces of wall and applying two coats of white wash Complete all as specfied and directed.
Material & labour for Rendering 10 mm thick CM 1:6 on stone masonry surface finished even & fair complete all as specified and directed.
M&L for Plain Cement concrete Type D-2, 1:4:8 (40mm graded aggregate), as in foundation, filling and mass concrete complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified and directed.
M&L for hard core of broken stone or boulders of guage n.exc, 63mm, deposited, spread and levelled in layers n.exc, 15 cm thick, watered and rammed to a ture surface complete all as specified and directed
M&L Non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in CM 1:4 finished fair and even for laying floor finishes/tiles Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed :- Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8mm thick, on vertical surface as in patch etc including 10mm thick rendering in CM (1:4), set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I).
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping and the like including weathering slightly rounded/chamferred angle with and including necessary use and waste of form work for fair faces of concrete complete all as specified and directed
S&F for steel work in tubular truss of square pipe hollow section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st-240 Complete all as specfied and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer Complete all as specfied and directed.
CHAUDHARY FURNITURE HOUSE
Panwar Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .