Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 CrAccepted-AOC KALIKA DAS ROAD NUTAN BAZAR P O DIST COOCH BEHAR 736101 | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | ₹18.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹19.1 CrRejected-Finance 545 G T ROAD HOWRAH WEST BENGAL 711101 | HOWRAH | HOWRAH | WEST BENGAL | 711101 | ₹19.1 Cr | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹19.2 CrRejected-Finance | ₹19.2 Cr | L3 | Rejected-Finance NOT L1 |
Tender Value
₹21.1 Cr
EMD Value
₹42.1 L
Closing Date
14 Feb 2026, 10:00 amClosed
Assistant Chief Engineer
Araksha Bhawan 3rd Floor Block DJ Sector II Salt Lake City
Construction of 5 nos. 200 Heads Barrack for Junior Constables/NVF/ HG Personnel and 1 no. 200 Heads for Lady Constables/ Junior Lady Constable at Belguma Police Lines under Purulia District. (1st Call)
2026_WBSPH_992500_1
WBPHIDCL/ACE/NIT- 142(e)/2025-2026
Open Tender
CIVIL AND ELECTRICAL WORKS
630 days
Refer to NIT
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹42.1 L
Yes
26 Feb 2026
21 Jan 2026
16 Feb 2026
21 Jan 2026
14 Feb 2026
31 Jan 2026
Civil Works Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. (a) Depth of excavation not execeeding 1,500 mm
Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. ( b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring .
Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(c) (iii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consoliding the same by through saturation with water ramming complete including the cost of supply of sand (payment to be made on measurment of finished quantity) (B) Do - by fine sand
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered or local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety
Controlled Cement concrete with well graded stone chips(20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications , submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in charge.Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [using concrete mixture] (b) M 25 Grade for GROUND FLOOR
Controlled Cement concrete with well graded stone chips(20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications , submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in charge.Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [using concrete mixture] (b) M 25 Grade for FIRST FLOOR
Controlled Cement concrete with well graded stone chips(20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications , submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in charge.Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [using concrete mixture] (b) M 25 Grade for SECOND FLOOR
Controlled Cement concrete with well graded stone chips(20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications , submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in charge.Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [using concrete mixture] (b) M 25 Grade for THIRD FLOOR
Controlled Cement concrete with well graded stone chips(20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications , submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in charge.Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [using concrete mixture] (b) M 25 Grade for FOURTH FLOOR
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade GROUND FLOOR
Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (A) AT GROUND FLOOR
Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (B) AT FIRST FLOOR
Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (C) AT SECOND FLOOR
Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (C) AT THIRD FLOOR
Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (D) AT FOURTH FLOOR
Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL (A) AT GROUND FLOOR
Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL (B) AT FIRST FLOOR
Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL (C) AT SECOND FLOOR
Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL (C) AT THIRD FLOOR
Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL (C) AT FOURTH FLOOR
Pre-Constructional Anti-termite measures: (B) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Brick work with 1st class bricks in cement mortar (1:6) in (A) In foundation and plinth
Brick work with 1st class bricks in cement mortar (1:6) in (A) In superstructure, (B) AT GROUND FLOOR
Brick work with 1st class bricks in cement mortar (1:6) in (A) In superstructure, (B) AT FIRST FLOOR
Brick work with 1st class bricks in cement mortar (1:6) in (A) In superstructure, (C) AT SECOND FLOOR
Brick work with 1st class bricks in cement mortar (1:6) in (A) In superstructure, (C) AT THIRD FLOOR
Brick work with 1st class bricks in cement mortar (1:6) in (A) In superstructure, (C) AT FOURTH FLOOR
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in (A) AT GROUND FLOOR
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in (B) AT FIRST FLOOR
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in (C) AT SECOND FLOOR
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in (C) AT THIRD FLOOR
Extra for using approved H.B netting in every third layer in 125 mm thick brick work
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item NO 60, polymer based paint as per item 59 (a) of Section (C).
Labour for Chipping of concrete surface before taking up Plastering work.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malaysian Sal (A) AT GROUND FLOOR
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malaysian Sal (B) AT FIRST FLOOR
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malaysian Sal (C) AT SECOND FLOOR
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malaysian Sal (C) AT THIRD FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster (A) AT GROUND FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster (A) AT FIRST FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster (A) AT SECOND FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster (A) AT THIRD FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster (A) AT FOURTH FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. With 6:1 cement mortar a) 20mm thick plaster OUTSIDE (A) AT GROUND FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. With 6:1 cement mortar a) 20mm thick plaster OUTSIDE (A) AT FIRST FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. With 6:1 cement mortar a) 20mm thick plaster OUTSIDE (A) AT SECOND FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. With 6:1 cement mortar a) 20mm thick plaster OUTSIDE (A) AT THIRD FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. With 6:1 cement mortar a) 20mm thick plaster OUTSIDE (A) AT FOURTH FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. With 6:1 cement mortar a) 15mm thick plaster INSIDE (A) AT GROUND FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 6:1 cement mortar b) 15mm thick plaster INSIDE (A) AT FIRST FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 6:1 cement mortar b) 15mm thick plaster INSIDE (A) AT SECOND FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 6:1 cement mortar b) 15mm thick plaster INSIDE (A) AT THIRD FLOOR
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 6:1 cement mortar b) 15mm thick plaster INSIDE (A) AT FOURTH FLOOR
Net Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 Sqmts
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm (A) AT GROUND FLOOR
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm (A) AT FIRST FLOOR
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm (A) AT SECOND FLOOR
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm (A) AT THIRD FLOOR
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(i) 32 mm thick (A) AT GROUND FLOOR
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(i) 32 mm thick (A) AT FIRST FLOOR
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(i) 32 mm thick (A) AT SECOND FLOOR
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(i) 32 mm thick (A) AT THIRD FLOOR
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf) GROUND FLOOR
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf) FIRST FLOOR
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf) SECOND FLOOR
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf) THIRD FLOOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats i) Water based interior grade Acrylic Primer GROUND FLOOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats i) Water based interior grade Acrylic Primer FIRST FLOOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats i) Water based interior grade Acrylic Primer SECOND FLOOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats i) Water based interior grade Acrylic Primer THIRD FLOOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats i) Water based interior grade Acrylic Primer FOURTH FLOOR
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality (A) AT GROUND FLOOR
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality (A) AT FIRST FLOOR
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) i) Standard Quality (A) AT SECOND FLOOR
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) i) Standard Quality (A) AT THIRD FLOOR
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) i) Standard Quality (A) AT FOURTH FLOOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats (A) AT GROUND FLOOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats(A) AT FIRST FLOOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats (A) AT SECOND FLOOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats (A) AT THIRD FLOOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats (A) AT FOURTH FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion GROUND FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion FIRST FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion SECOND FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion THIRD FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion FOURTH FLOOR
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a)b) iv) On Steel and other Metal Surface Two coat with any shade except white
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at FLOOR (A) AT GROUND FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at FLOOR (A) AT FIRST FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at FLOOR (A) AT SECOND FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at FLOOR (A) AT THIRD FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at Wall (A) AT GROUND FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc..(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at Wall (A) AT FIRST FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc..(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at Wall (A) AT SECOND FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc..(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of Each tile above 0.09 Sq.m (i) Coloured decorative at Wall (A) AT THIRD FLOOR
18 mm. to 22 mm. thick, kota stone slab Setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]Extra cost of labour for prefinished and premoulded Nosing to treads of steps,(A) AT GROUND FLOOR
18 mm. to 22 mm. thick, kota stone slab Setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]Extra cost of labour for prefinished and premoulded Nosing to treads of steps,(A) AT FIRST FLOOR
18 mm. to 22 mm. thick, kota stone slab Setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]Extra cost of labour for prefinished and premoulded Nosing to treads of steps,(A) AT SECOND FLOOR
18 mm. to 22 mm. thick, kota stone slab Setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]Extra cost of labour for prefinished and premoulded Nosing to treads of steps,(A) AT THIRD FLOOR
18 mm. to 22 mm. thick, kota stone slab Setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]Extra cost of labour for prefinished and premoulded Nosing to treads of steps,(A) AT FOURTH FLOOR
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (A) AT GROUND FLOOR
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (A) AT FIRST FLOOR
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (A) AT SECOND FLOOR
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (A) AT THIRD FLOOR
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (A) AT FOURTH FLOOR
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps.
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. GROUND FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. FIRST FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. SECOND FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. THIRD FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. FOURTH FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(iii) Centre hung ventilators as per I.S. sizes 580 mm. GROUND FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (iii) Centre hung ventilators as per I.S. sizes 580 mm.FIRST FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(iii) Centre hung ventilators as per I.S. sizes 580 mm.SECOND FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (iii) Centre hung ventilators as per I.S. sizes 580 mm. THIRD FLOOR
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick
Extra for fixing glass panes in steel window.
(iv) Two point nose steel handle including fitting and fixing.
(vi) steel peg stay 300 mm long including fitting and fixing.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). (a) 40mm X 6mm, 250mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mm
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.250mm long
(ii) Anodised aluminium floor door stopper
Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. (ix) 300mm long x 10mm dia. bolt.
Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. (vi) 200mm long x 10mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod) (v) 125 mm grip x 12 mm dia rod.
Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge (i) Glass - 3mm. Thick (b) 25 mm. wide strip
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required). For Water Proofing at roof
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur variety (ROOF TRETMENT)
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr (A) AT GROUND FLOOR
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr (A) AT FIRST FLOOR
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr (A) AT SECOND FLOOR
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr (A) AT THIRD FLOOR
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr (A) AT FOURTH FLOOR
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. III) For built up sections / srtuctural members of specified sections weighing not less than 22.5 Kg./m Ground Floor
SANITARY & PLUMBING WORKS Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate No separate payment will be made for accessories, specials.) pvc Pipes(dia) 100 mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)n the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes (Dia) 50 mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)n the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes (Dia) 40mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)n the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes (Dia) 32mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)n the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes (Dia) 25mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)n the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Concealed work -- PVC Pipes (Dia) 15mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)n the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Concealed work (Dia) 20mm
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (i) 100 mm dia
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (i) 100 mm dia
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 50 mm dia
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 40 mm dia
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 32mm dia
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 25mm dia
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (c) C.P. urinal flush pipe fittings range of three
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing CloSet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(a) E.W.C. (ii) Plastic (hallow type) white
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm
Supplying, fitting and fixing towel rail with two brackets. (a) (ii)C.P. over brass 25 mm dia. and 600 mm long
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying fitting fixing PTMT smart shelf of approved make of size 300 mm
Suppling fitting fixing soap holder a)PTMT (Prayag or Equivelent)
Supplying, fitting and fixing liquid soap container. (a) Cromium plated.
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.White
Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm long
Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (v) 900 mm long
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
Supplying, fitting and fixing shower of approved brand and make (a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(iii) Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing bib cock or stop cock. (ii) Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Mtr. Length b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Mtr. Length c) 160 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings (ii) Plain Tee b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings (iii) Door Tee b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings v) Plain Y b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings vi) Door Y (LH) & (RH b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings ix) Bend 45º b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings x) Bend 87.5º b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings xi) Door Bend (T.S.) b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings xiii) Cross Tee b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings xv) Vent Cowl b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings xvi) Pipe Clip b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings xxix) Passover b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings Door Cap b) 110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings xv) Vent Cowl (a) 75 mm
Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Above ground b) 110 mm
Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (B) Below Ground a) 160 mm
Supplying, fitting and fixing C.I. round grating. (ii) 150 mm
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity
Labour for hoisting plastic water storage tank.ii) Above 1500 litre upto 5000 litre capacity.(a) Upto 4th story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety.
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. A) With Pakur variety 200 USER
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia.
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. (a) Depth up to 150 mm
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. (b) For each additional Depth of 150mm and part thereof
Water Bound Macadam Base Course Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) manual means
60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mmmedium sand bed on 250mm thk WBM/ WMM base course &250 mm thk bound gnaular /granular sub-base courseincluding cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) (i) Colour Decorative
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in- Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
ELECTRICAL WORKS Supplying and fixing 415V, 100 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make : L&T/Havells/HPL or equivalent as approved by EIC.)
Supplying and fixing 415V, 32 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make : L&T/Havells/HPL or equivalent as approved by EIC.) ( For Pump or Other Connection Purpose)
Supplying and fixing 6 way double door Vertical TPN(Up to 160A) MCB Distribution board (Seimens/ABB/Legrand/ as approved by EIC) for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 125 A Four Pole MCCB -- 1 nos 63 A TP MCB - - 3 nos 32 A TP MCB - - 3 nos
Supplying & fixing sheet metal (16 SWG), 4 bars, 415 V, 100/125 A Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) Dimension of Al. bars [85mm long] : 4 x 25 x 5 mm Dimension of Sheet Metal Box : 500 x 150 mm
Supplying and fixing double door 4 Way Horizontal TPN MCB Distribution board Enclosure (607715) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including following items. (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.) a) 415V, 63 A FP Isolator...................... 1 Nos. b) 240 V, 40 A SP MCB (10kA & 'C' curve)............... 3 Nos. c) 240V, 16/32 A SP MCB (10kA & 'C' curve)............. 9 Nos.
Supplying and fixing (2+12 Way) double-door SPN MCB Distribution Board Enclosure (607712) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.) a) 240V, 40A DP Isolator............... 1 Nos. b) 240V, 6 - 32A SP MCB (10kA & 'C' Curve).............. 12 Nos.
Supplying and fixing MCB SS 4 pole enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment including (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.) a) 40 A DP MCB Isolator............. 1 Nos. b) 6-32A range SP MCB('C' Curve & 10kA Charecteristics)... 2 Nos. (For Compound Light & Street Light Connection Purpose)
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three (03) no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (a) 2 Module Switch Board including with (b) Supply & Fixing 240 V 16 A Modular key type 2 nos switch (Brand Legrand/Crabtree or equivalent as approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required . a) 240 V, 16 A Modular switch ................ 2 Nos.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent as approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand Legrand/Crabtree or equivalent as approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Average Run 8 Mtr).
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand Legrand/Crabtree or equivalent as approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Average Run 10 Mtr).
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand Legrand/Crabtree or equivalent as approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish (ON BOARD) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.
Supply & Fixing 240 V, 2nos.6A, 3 pin Modular type plug socket (Brand Legrand/Crabtree or equivalent as approved by EIC) with 2nos.6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand Legrand/Crabtree or equivalent as approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make Legrand / Crabtree or equivalent as approved by EIC.)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (For PP/ Computer Board) (i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (For TPN DB to FP Enclosure ) (i) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (For TPNDB to SPN DB) (y) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (For VTPN to TPN DB) (d1) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent asapproved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 2.5 Sq mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 4 Sq mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 6 Sq mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 10 Sq mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 16 Sq mm.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make Legrand / Crabtree or equivalent as approved by EIC.) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.
Fixing only bulk head ceiling fitting on wall/ceiling by screws etc.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: a) 23 cm (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al , 23 cm Exhaust fan (9").
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. (For Compound Light)
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. (Use for Street & Flood Light)
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall. i) Auto transformer starter of 7.5 HP Pump.
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (For Compound Light) (a) 200 x 150 x 100mm .
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 2 core upto 6 sq mm including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (ii) For 2 core 6 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables with socket as below : For 4 core upto 10 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables including Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. For 4 core 95 sq mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables with socket as below : For 4 core 185 sqmm
Laying of cable upto 4 core 95 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Laying of one No. cable upto above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, includingfilling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (50 mm dia).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. a) Solid 4 SWG GI wire.
Erection of Single Steel tubular pole of length as given below with sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly :- Upto 9.0 mtr, Size 0.6x0.6x1.70 mts. (Street Light)
Providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole. (Street Light)
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint - Upto 9.0 mtr. long pole :- a) 1st coat of aluminium paint over 1 coat of RO priming b) 2nd coat of aluminium paint over 1st coat
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works.
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run.
Supply & fixing Meter guard of dimention (6' x 4' x 12" depth) fabricated by angle/flat box type structural frame welded & covered with 12 SWG wire mess all over except the back side. The front side should be provided with two (2) pair of hinged doors with mechanical locking arrangement including painting with Aluminium paint. The wire mess guard should have sufficient bifurcated legs for rigidly grouting it on wall incl. earthing attachment as per direction of E.I.C.
Supply and Fixing 12 mm thick water and vermin proof super quality ply wood of size (6 ft x 4 ft) to be fixed on wall with suitable long screws fasterner etc after painting the near side with Japan paint.(PWD civil page no 173 item no 2 Rs. 1709.00/ sq mt, with 18% GST 2016.62/ sq mt.)
Supply & delivery of 1.1kV grade 2 Core 6 sqmm XLPE Aluminium Armoured Cable. (Make - Gloster/ Havells / KEI) or equivalent as approved by EIC. (For Compound Light)
Supply & delivery of 1.1kV grade 4 Core 10 sqmm XLPE Aluminium Armoured Cable. (Make - Gloster/ Havells / KEI) or equivalent as approved by EIC. [Use For Street Light Connection]
Supply & delivery of 1.1kV grade 4 Core 95 sqmm XLPE Aluminium Armoured Cable. (Make - Gloster/ Havells / KEI) or equivalent as approved by EIC. (For Main Supply Cable)
Supply & delivery of 1.1kV grade 4 Core 185 sqmm XLPE Aluminium Armoured Cable. (Make - Gloster/ Havells / KEI) or equivalent as approved by EIC. [Use For Incommer to Feeder Pillar.]
Supply & delivery at site of swaged type steel tubular pole (410‐SP‐29) of over all length 9 mtr. of section (Bottom-5m, Middle -2m, Top -2m) & outside dia & thickness (Bottom- 139.7x4.50, Middle-114.3x3.65, Top-88.9x3.25) having approx weight of the pole including sole plate 125 Kg, The top end of the pole should be reduced to enable fixing of LED fittings. (Make - Banshal / Calcutta Poles or equivalent as directed by EIC)
Supply & installation of 4 mm thick M.S. out door type Feeder Pillar Box(Size - 1050 mm (H) X 900 mm (W) X 400 mm (D)) having both side ventilation louvers with inclined roof of suitable size and diamention having hinged door,name plate,E.I Danger board with powder coating paint & mechanical locking arrangement suitably grouted on 200mm masonary platform 450 below G.L. & 500mm above G.L. plastering & neatly cemented finish. The Feeder pillar box should comprise double door type cubicle panel inside it, fabricated by 2.5 mm thick M.S. sheet with necessary slot for incomming outing MCCB/MCBs bus bar & necessary interconnection with suitable capacity PVC insulated copper wire duly socketed at both end comprising of the following control device.MCB/MCCB INCOMER: (Make : L&T/Legrand/Seimens/ABB or equivalent as approved by EIC) i) 415V, 250A 4P 25KA MCCB TM RELEASE WITH HANDLE & SPEADER .............. 1 No ii) LED Indicator Lamp (R/Y/B) .................. 1 No iii) 6A SP MCB ........... 3 Nos Out Going: (Make : L&T/Legrand/Seimens/ABB or equivalent as approved by EIC) Fabrication Cost with 4 bar Aluminium Bus Bar (300A) - 1 set i) 415V, 160A 4P 25 KA MCCB TM RELEASE WITH HANDLE & SPEADER .............. 6 Nos ii) 415V, 63A 4P MCB 10KA "C Curve" ................. 1 No iii) 415V, 32A 4P MCB 10KA "C Curve" .............. 1 No (For Main Supply Distribution)
Supply of 4' , 20 W robust and high performance, glare free and smooth light distribution batten tube light complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener. Efficacy: 100 lm/W. (Make : Crompton cat no : TRIMLINE NEU - CCS-103-20-65-SL-DP-NWH (CCT-6000K)/ Philips / Legero or equivalent as approved by EIC.)
Supply of 10 W Bulk Head Fitting with LED Light. (Make - Philips WT202W LED 10S CW PSU S3 PC/Crompton Cat No.- CIS-306-10-30-SL-DP-NBK / Legero or equivalent as approved by EIC).
Supply of 5 W Night Bulb (DECO BRIGHT )with all necessary accessories as directed by EIC. (Make - Philips : HSN Code : 85395200/ Legero / Crompton or equivalent as approved by EIC).
Supply & Fixing 9W LED bulb for all surface mount indoor general lighting application with all necessary accessories as directed by EIC. (Make :- Century LED / Legero / Orient) or equivalent as approved by EIC.
Supply of 90 W LED light fitting High performance street light luminaire with Single Die ceramic base high power LED light source, IP66 protection, PDC housing & aesthetic finless design and toughened glass cover and street light optics for lighting of internal B2 category roads in cities. Pole Dia.: 32-40 mm(Make :- Philips BRP033 LED90 CW SLR GR PSU SPD/ Crompton, RAPTOR PRO, Cat No.- CRP-411-90-57-SL-GL-NSG /Legero or equivalent as approved by EIC.
Supply of 1200MM Sweep Ceiling Fan. (Make - Usha STRIKER NEO HI-SPEED / Orient New Breeze / Havells White FHCEE5SWHT48/ or equivalent as apporved by EIC).
Supply and delivery of 230 mm (9") sweep heavy duty exhaust fan ( Make : Usha, 300MM S.PH TURBO HDEF 900RPM ISI EPC/Crompton/Orient or equivalent as approved by EIC .)
Supply and delivery of three phase, 415 Volts, 7.5 HP Monoblock Horizontal Openwell Submersible pump motor Set as per the required discharged head, dicharge rate and outlet size. (Make- KSB : MR 7.5 C- 90-75-21 SD 2.5 sq.mm IN752632 /Kirloskar or equivalent as approved by EIC).
Supply of control panel suitable for 3-Phase, 415V, 7.5 HP Submersible pump motor Set comprising of FASD starter, ammeter & voltmeter, indicator lamp to be fixed on wall incl making connection & necy earthing attachment.(Make - L&T, Cat No : CS94091SOVO , MU-G15 FASD Starter, or equivalent).
Supply & delivery of 1.1kV grade 3 Core 4 sqmm flat submersible Cable. (Make - Polycab / Finolex / Havells / KEI) or equivalent as approved by EIC. (For Monoblock Submersible Pump)
Labour charge for Testing and lowering & Installing the 7.5 HP Monoblock Submersible Pump motor set with suitable flat submersible cable along with all necessary items .
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.18 MB
Tendernotice_2.pdf
PDF • 0.20 MB
Tendernotice_3.pdf
PDF • 0.41 MB
Tendernotice_4.pdf
PDF • 2.43 MB
BOQ_2427011.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid