Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.3 LAccepted-Finance CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | ₹61.3 L | L1 | Accepted-Finance LOWEST BIDDER |
| 2 | L2₹63.4 LRejected-Finance 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | ₹63.4 L | L2 | Rejected-Finance 2ND LOWEST BIDDER |
| 3 | L3₹63.5 LRejected-Finance 0 JANAI JANAI CHANDITALA HOOGHLY WEST BENGAL 712304 UDYAM WB 07 0059321 | HOOGHLY | WEST BENGAL | 712304 | ₹63.5 L | L3 | Rejected-Finance 3rd LOWEST BIDDER |
| Sl No | Description | Qty | Unit | CHAKRABORTY ELECTRIC L2 | DAS ENTERPRISE L3 | TAPAN ELECTRICS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and Fixing of 7 Mtr. Galvanized Octagonal Pole on the existing foundation with Top A/F- 70, bottom A/F- 135 or above, Thickness 3 mm, Wind speed shall be considered 50m/s as per IS:875 including Supply & fixing of “J” Type foundation bolts as per EN-B Grade manufactured from special steel along with nuts, washers, Anchor Plate, of required size and templates. A) Material Construction Shaft Equivalent to BSEN 10025 or as per IS 2062 B) Materials grade of Base Plate shall be E250(BR)as per IS:2062 C) Galvanization as per IS 4759
[Make :- Surya/Transrail/Valmont] | 42 | Nos | 5,000 ₹2.1 L | 5,000 ₹2.1 L | 33,666 ₹14.1 L |
| 2.00 | Supply, Installation, Testing & Commisioning of 120W solar All in one (Integrated) LED streetlight system, Solar PV panel: Mono Crystalline PV Panel 200WP (Any MNRE Approved) , Solar Battery- 12.8V 100AH Lithum Ferrous Phosphate Battery with BMS BIS approved high lumen efficasy >160 lm/w , Housing - Aluminum, Charge controller- MPPT Intergral charge controller (Inbuild in to the street light) CCT-6000-6500K, IP65, Impact Resistance(IK): IK08(Except for solar panel), Dimming facility available.
[Make- Surya/Phillips /Crompton/Transrail]
A minimum 5-year on-site warranty shall be provided by the Original Equipment Manufacturer (OEM). Warranty documents must be submitted to the Engineer-in-Charge (EIC) prior to installation.
N.B. The solar lighting company must have an in-house NABL-accredited laboratory.
The successful bidder must submit LM79 and LM80 test reports for the luminaire and LED, respectively, from a NABL-accredited third-party laboratory.
The following valid type test reports shall be submitted along with the bid:
i) Luminaire Safety: IEC 60598-1:2014 & IEC 60598-1:2014 AMD1:2017
ii) MPPT Performance: EN 50530
iii) Battery Safety (LiFePO₄, IP68): IEC 62133, UL 1642, UN 38.3
iv) Solar Panel Safety: IEC 61730-1, IEC 61730-2, IEC 61215 | 42 | Nos | 1,45,913 ₹61.3 L | 1,46,000 ₹61.3 L | 1,00,000 ₹42 L |
| 3.00 | Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. | 42 | Set | 10 ₹420 | 10 ₹420 | 3,000 ₹1.3 L |
| 4.00 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. | 42 | Set | 10 ₹420 | 10 ₹420 | 1,000 ₹42,000 |
| 5.00 | Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. | 2,270 | RM | 2 ₹4,540 | 2 ₹4,540 | 150 ₹3.4 L |
| 6.00 | Supply and laying 4 SWG G.I. wire for continuous Earthing as per G.S. | 250 | RM | 1 ₹250 | 1 ₹250 | 50 ₹12,500 |
| 7.00Terms & Conditions: | ||||||
| 7.01The agency must procure the material from the manufacturer/OEM or from their authorised sales channel so that the standard warranty/support of the manufacturer/OEM becomes applicable to the product and to be delivered and installed by them. | ||||||
| 7.02Documents that authenticate such procurement from the manufacturer/OEM or from their authorised sales channel so that the standard warranty/support should be send from the E-Mail of the manufacturer/OEM or from their authorised sales channel to the email of EIC. and hard copy of it to be submitted during execution of work/submission of bill. | ||||||
| 7.03If any refurbished material is supplied and installed, penal action will be taken as per existing rule. | ||||||
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
19 Mar 2026, 2:30 pmClosed
SE,SWEC,PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.Dte), South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur
Construction of Proposed ROB at Km. 283/37 (283/32-34) in lieu of Level Crossing No. AM 1 between Adra Sanka Railway Station at Adra Station Yard of South Eastern Railway on the Kashipur Adra Raghunathpur Road in the district of Purulia, West Be
2026_WBPWD_1016331_1
WBPWD/SE/SWEC/NIQ47/2025-26
Open Tender
ELECTRICAL WORKS ORG
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.2 L
OFFICE OF THE SE,SWEC,PWD,MIDNAPORE
22 Jun 2026
27 Feb 2026
23 Mar 2026
27 Feb 2026
19 Mar 2026
10 Mar 2026
9 Mar 2026
Supply and Fixing of 7 mtr. Galvanized Octagonal Pole on the existing base plate (fixed by Civil Wing) with Top A/F 70, bottom A/F 155, Thickness 3 mm, Wind speed shall be considered 50m/s as per IS:875 including Supply & fixing of “J” Type foundation bolts as per EN-B Grade manufactured from special steel along with nuts, washers, Anchor Plate, of required size and templates A) Material Construction Shaft Equivalent to BSEN 10025 Or As per IS 2062 B) Materials grade of Base Plate shall be E250(BR)as per IS:2062 C) Galvanization as per IS 4759 [Make :- Surya/Transrail/Valmont]
Supply, Installation, Testing & Commisioning of 120W solar All in one(Integrated) LED streetlight system, Solar PV panel: Mono Crystalline PV Panel 200WP (Any MNRE Approved) , Solar Battery- 12.8V 100AH Lithum Ferrous Phosphate Battery with BMS BIS approved high lumen efficasy >160 lm/w , Housing - Aluminum, Charge controller- MPPT Intergral charge controller (Inbuild in to the street light) CCT-6000-6500K, IP65, Impact Resistance(IK): IK08(Except for solar panel), Dimming facility available. [Make- SURYA/Phillips /Crompton] A minimum 5-year on-site warranty shall be provided by the Original Equipment Manufacturer (OEM). Warranty documents must be submitted to the Engineer-in-Charge (EIC) prior to installation. N.B. The solar lighting company must have an in-house NABL-accredited laboratory. The successful bidder must submit LM79 and LM80 test reports for the luminaire and LED, respectively, from a NABL-accredited third-party laboratory. The following valid type test reports shall be submitted along with the bid: i) Luminaire Safety: IEC 60598-1:2014 & IEC 60598-1:2014 AMD1:2017 ii) MPPT Performance: EN 50530 iii) Battery Safety (LiFePO₄, IP68): IEC 62133, UL 1642, UN 38.3 iv) Solar Panel Safety: IEC 61730-1, IEC 61730-2, IEC 61215
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply and laying 4 SWG G.I. wire for continuous Earthing as per G.S.
Terms & Conditions:
The agency must procure the material from the manufacturer/OEM or from their authorised sales channel so that the standard warranty/support of the manufacturer/OEM becomes applicable to the product and to be delivered and installed by them.
Documents that authenticate such procurement from the manufacturer/OEM or from their authorised sales channel so that the standard warranty/support should be send from the E-Mail of the manufacturer/OEM or from their authorised sales channel to the email of EIC. and hard copy of it to be submitted during execution of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rule
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.53 MB
BOQ_2496962.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid