Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-Finance NISARI NALLUR FEROKE P O CALICUT 673 631 | KOZHIKODE | KERALA | 673631 | ₹3.4 L | L1 | Accepted-Finance ACCEPTED |
| 2 | L2₹3.7 L+₹31,802.45 (9.35%)Accepted-Finance | ₹3.7 L+₹31,802.45 (9.35%) | L2 | Accepted-Finance ACCEPTED |
| Sl No | Description | Qty | Unit | ANJAL.P L1 | DINEESH M.P L2 |
|---|---|---|---|---|---|
| 1.00WOMEN WELNESS CENTRE ELECTRIFICATION | |||||
| 1.00 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B | 76 | point | 1,030 ₹78,280 Lowest | 1,126.33 ₹85,601.08 |
| 1.00 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 2 | point | 1,258 ₹2,516 Lowest | 1,488.87 ₹2,977.74 |
| 1.00 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 90 | metre | 202 ₹18,180 Lowest | 222.11 ₹19,989.9 |
| 1.00 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 70 | metre | 238.5 ₹16,695 Lowest | 262.25 ₹18,357.5 |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 50 | metre | 286 ₹14,300 Lowest | 318.5 ₹15,925 |
| 1.01 | 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire | 20 | metre | 382 ₹7,640 Lowest | 418.42 ₹8,368.4 |
| 1.01 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 6 | each | 80 ₹480 Lowest | 97.99 ₹587.94 |
| 1.01 | 90.10.3.17:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket | 6 | each | 150 ₹900 Lowest | 176.89 ₹1,061.34 |
| 1.01 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 20 | each | 321 ₹6,420 Lowest | 351.14 ₹7,022.8 |
Tender Value
₹4.1 L
EMD Value
₹10,325
Closing Date
10 Sept 2026, 11:00 amClosed
ASSISTANT ENGINEER ,MOODADI GP
ASSISTANT ENGINEER ,MOODADI GP
ELECTRIFICATION
2026_LSGD_867308_33
AE/MDY/TENDER/01/P/2026-27
Open Tender
Civil Works - Roads
Item Rate
MOODADI
Please refer Tender documents.
8 documents required · 8 mandatory
₹910
Yes
₹10,325
Yes
14 Sept 2026
3 Sept 2026
12 Sept 2026
3 Sept 2026
10 Sept 2026
3 Sept 2026
3 Sept 2026 - 8 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1WOMEN WELNESS CENTRE ELECTRIFICATION | |||||
| 1.001 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B | - | point | - | - |
| 1.002 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | - | point | - | - |
| 1.003 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | - | metre | - | - |
| 1.004 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | - | metre | - | - |
| 1.005 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | - | metre | - | - |
| 1.006 | 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire | - | metre | - | - |
| 1.007 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | - | each | - | - |
| 1.008 | 90.10.3.17:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket | - | each | - | - |
| 1.009 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | - | each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 0.25 MB
Tendernotice_3.pdf
PDF • 0.26 MB
Tendernotice_4.pdf
PDF • 0.24 MB
Tendernotice_5.pdf
PDF • 0.24 MB
Tendernotice_6.pdf
PDF • 0.24 MB
Tendernotice_7.pdf
PDF • 0.97 MB
BOQ_1468814.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .