Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹1.8 L+₹35,936 (25.2%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹1.8 L+₹38,159 (26.7%)Accepted-Finance | L3 | Accepted-Finance L3 |
Tender Value
₹1.1 L
EMD Value
₹2,000
Closing Date
30 Apr 2022, 12:00 pmClosed
SE, EDC, Rampur
Office of the SE, EDC, Rampur
10/2022-23(EDCR) Replacement of G I Jajar wire by ACSR Weasal Conductor and increasing load capacity near Priti Nursing Home Civil lines, under EDD-I, Rampur
2022_PVVNL_691334_1
10/2022-23(EDCR)
Open Tender
Electrical Works
Lump-sum
45 days
Office of the SE, EDC
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
SE, EDC, Rampur
₹2,000
6 Sept 2022
21 Apr 2022
30 Apr 2022
21 Apr 2022
30 Apr 2022
21 Apr 2022
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
8.5 Mtr long PCC Pole.
ACSR Weasal Conductor
Scrap GI wire (site to store)
other line material etc.
250 KVA 11/0.44 KV Three Phase Transformer and old 11/0.4 KV 100 KVA Transformer from site to store
Cartage of Healty Transformer from store to site, dismantling of HT & LT connection & replace of follwoing capacity T/F from substation double poles/plinth by Healthy transformer(including connection) and loading and unloading with associated work at both ends within 70 kms.
Increasing load capacity of overloaded 100 KVA by Separate 250 KVA trasnformer
a) Single support Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
8.5 Mtr long PCC Pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Single support
8.5 Mtr long PCC Pole
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs
Make Plinth for 250 KVA Transformer with size 2*2*1.5M and CC 1:3:6 (cement, course sand and stone grit) with muffing etc. as per RESPO Norms and as per direction of Supervising Engineer.
Fencing of 250 KVA Transformer after providing fiber fencing as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of ACSR Weasal Conductor as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling of G I wire of existing 11 KV Line
Spreading ,stringing and binding of LT Cable 3.5x400 sqmm
Painting of M S works inculding material with all cost
Providing X-Arm Clamp with Bolts and Nuts
Providing F Bracket with bolts & nuts
Providing stone pad
Providing Barbed wire
Providing and fixing Danger board with barbed wire including jumper
munfad electricals
Krishna Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .