Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance GROUND FLOOR BUILDING NO 45 MAIN MARKET CHOWKIBAL MAIN MARKET CHOWKIBAL CHOWKIBAL KUPWARA JAMMU KASHMIR 193224 | KUPWARA | JAMMU AND KASHMIR | 193224 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹16.6 L
Closing Date
16 Dec 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Sgr
Barbarshah Sgr
Internal Electrification with controlling and protection switcher Gear devices for 100 Bedded Girls Hostel at Kaloosa Bandipora
2021_PWDJK_151674_2
E/NIT/203/2021/22dtd07/12/2021
Open Tender
Electrical Works
Item Rate
30 days
Internal Electrification with controlling and prot
as per BOQ
7 documents required · 7 mandatory
₹800
Executive Engineer RNB Electric Division Sgr
Exempted
16 Dec 2021
7 Dec 2021
16 Dec 2021
7 Dec 2021
16 Dec 2021
7 Dec 2021
120 days
Amount
Wiring for Light Point with 1.5 sq mm FRLS PVC Insulated multi strand copper conductor single core cable of Standard make dully ISI Marked in surface / recessed medium class PVC conduit, with 6 Amp One way Switch of fantasy series of ssk with cover fitted on Hylam plate , recessed in walls with refacing of walls.The job includes circuit wiring from DB to first switch in sub circuit ( Excl Cost of Conduit )
Wiring for 16 Amp Power Sockets 3x4.0 sq mm ( P+N+E) FRLS PVC Insulated multi strand copper conductor single core cable of Standard make dully ISI Marked in surface / recessed medium class PVC conduit, with 16 Amp switch and socket of fantasy series of ssk with cover fitted on Hylam plate fitted on recessed in walls with refacing of walls. ( Excl Cost of Conduit) Average legth of circuit upto 8 Mts long. and max 2 points to be wired in one circuit )
Wiring For 6 Amp Light Power Socket Points Plug with 3x2.5 sq mm (P+N+E) FRLS PVC Insulated multi strand copper conductor single core cable of Standard make dully ISI Marked in surface / recessed conduit medium class PVC conduit ( Excl cost of Conduit ) .The job includes p/f 2 no of 6 Amp 5 pin socket and 2- No of 6 Amps switch of Fantasy series of ssk with cover fitted on Hylam sheet fitted recessed in walls complete with refacing of walls, ( excluding cost of conduit ) Average legth of circuit upto 8 Mts long. and max 2 points to be wired in one circuit )
Providing, and laying through conduits & testing of wiring for telephone sockets in 2-pair telephone wire of approved make , laid through PVC conduits excl. cost of conduits.
Supply , Laying and connecting of 10 sq. mm FRLS PVC Insulated multi strand copper conductor single core cable of Standard make dully ISI Markede laid through conduit excluding cost of conduit for heating sub-main.
Supply , Laying and connecting of 6 sq. mm FRLS PVC Insulated multi strand copper conductor single core cable of Standard make dully ISI Marked laid through conduit excluding cost of conduit for lighting sub-main and earth sub-main.
Supply , Laying and connecting of 4 sq. mm FRLS PVC Insulated multi strand copper conductor single core cable of Standard make dully ISI Marked laid through conduit excluding cost of conduit for invertor /solar sub main.
Supply and laying of PVC medium grade Conduit/ channel to be laid on surface with screws fixed in rowel plugs complete with all allied accrues like bends, tees etc. for laying of conduits ,including cutting of walls with power cutter and refacing of same to original position by way of applying POP/Cement concrete of required ratio
25 / 31 mm dia
Supply. Installation, testing and commissioning of 1200 mm sweep heavy duty Ceiling fans of Standard make dully isi marked complete with connections.. (to be got approved before installation) complete with ceiling rose and connection wire.
Supply and fixing of 350 watts Electronic Fan dimmer of Top Line Series SSk/Havel's make
Supply. Installation, testing and commissioning of 250 mm sq Shutter Type Exhaust fans of Standard make dully isi marked complete with connections.
Providing ,Installation ,Testing and Commissioning of 18-20 Watt LED down lighter ( round /square) surface/recess mounted light fixture of standard make dully isi marked (besides other feature ,maximun lumens per watt will be taken into consideration while approving the fixture ) .The job includes replacement warrenty of lighting fixuture for a period of two years (incase any fixture is damaged what so ever reason) reckoned from date of sucessful commissioning
Providing and fixing of AC/DC bell of Standard make complete with batteries.
supply/ installation/testing and commissioning of (main Panel ) mounted compartmentalized , 415 volts TPN MCCB Main Distribution Panel power coated ,fabricated out of heavy guage sheet steel of adequate size to accommodate following accessories having dust protected, vermin proof incl earth terminal with all necessary accessories as required Incomer-1st (Normal Supply ) 400 Amp TPN MCCB of Legrand/L&T/ABB/Hugger/Siemens make with breaking capacity of 35 KA = 1 no 400 Amp TPN Bus-bar = 1 no Volt meter =1 no Ammeter = 1no CT coils for Am meter 300 /5A = 1 set Incomer-2nd (D.G Supply) 100 Amps F.Pole Change over Switch of Havells /Eq.make 200 Amps TPN Bus Bar Aluminium = 1 Set Volt meter =1 no Ammeter = 1no CT coils for Am meter 300 /5A = 1 set Incomer-3rd (inverter /Solar Supply) 100 Amps Double Pole MCB of Legrand/L&T/ABB/Hugger/Siemens make 200 Amps TPN Bus Bar Aluminium = 1 Set Volt meter =1 no Ammeter = 1no CT coils for Ammeter = 1 set Outgoing 63 Amps DP MCB of Legrand/L&T/ABB/Hugger/Siemens make = 10 No 40 Amps DP MCB of Legrand/L&T/ABB/Hugger/Siemens make = 10 No 32 Amps DP MCB of Legrand/L&T/ABB/Hugger/Siemens make= 10 No
Chemical Earthing with 2 mts long GI electrode to 50 mm dia G I Pipe placed verticaly in 100 mm dia bore dully drilled with hand drill and filed with required quantatity of chemical and man hole cover at top. The job includes extending of Earthing fron Eart Electrode to Main L T panel with 19 x5 mm G I Strip in one run
Providing of Maintenance Free Earthing System (G.I to G.I) using copper bounded earthing steel rods 5/8 inches in dia dully bored manully with 250 micron copper molecular bonding along with 2 bags ( 11.5 Kg each) of Ground Enhancement Material (GEM) or Equivalent with each rod to reduce the soil resistivity to a considerable value.Incl Providing and fixing of 8 No. copper wire for extension of earting from earthing electrode to Controlling Panel in One run.
Supplying and fixing of following way prewired MCB double door distribution Boards of sheet steel of standard make dully isi marked Double door on surface / recess complete with refacing of walls.
Supplying and fixing of 6-10-16 -20- Amps S Pole rating 240/415 volts "C" Curve MCB of Standard make dully isi marked complete with connections.
Supplying and fixing of 63 Amps rating DP 240/415 volts of "C" Curve MCB of Standard make dully isi marked complete with connections.
Supplying and fixing of 32 -40 Amps rating DP 240/415 volts of "C" Curve MCB of Standard make dully isi marked complete with connections.
Supply, installation, testing ad commissioning of 30 Watts LED flood ligh luminaries (IP66) of reputed dully isi marked.having Aluminium die Cast housing of standard make (besides other feature ,maximun lumens per watt will be taken into consideration while approving the fixture ) .The job includes replacement warrenty of lighting fixuture for a period of two years (incase any fixture is damaged what so ever reason) reckoned from date of sucessful commissioning
Supply,Installation,Testing and Commissioning of 10 KVA Single Phase Relay type Voltage Stabilizer of Chinar /Alba/electrified ,With input voltage of 90-220 Vots & Ouput voltage of 220 Volts ± 5% complete with 0ne yaer warranty against any manufacturer defects
Supply ,laying ,connecting ,testing and commissioning of 95 Sq.mm 31/2 Core PVC /XLPE armoured cable of reputed make dully isi marked ,incl p/f of aluminium thimbles of required size and numbers dully crimped with hydraulic crimping tool on i/p & o/p side ,incl making of necessary connections complete job. as main serivce line from near by LT Pole
Supply ,installation ,testing and commissioning of 5-Spikes Brass copper lightning arrestor for protection of building against lightning . The arrestor should be made of Brass copper having 9.2 mm in diameter and 915 mm in Length with base plate of 8.5 x 8.5 cm & 5-Spikes ,to be fitted on roop top of building complete with nuts and bolts of sorts
Providing of Maintenance Free Earthing System (G.I to G.I) using copper bounded earthing steel rods 5/8 inches in dia dully bored manully with 250 micron copper molecular bonding along with 2 bags ( 11.5 Kg each) of Ground Enhancement Material (GEM) or Equivalent with each rod to reduce the soil resistivity to a considerable value. .incl providing and laying of 19 x 3 mm size Copper Strip in one run (independently/seperately for each arrestor for extension of earthing from earth electrode to lightning arrestor at roof top of building .
AMIN ELECTRICALS
M/s MUSAIB AND CO
M/s Altaf Ahmad Lone
SADA ELECTRICALS
M/S JAY KAY ELECTRICALS and SUPPILERS
stage.html
html • 0.03 MB
finance_334556.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .