| 1.00Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size after taking down complete all as specified and directed by Engr-in-charge and directed as follows : | ||||||
| 1.10 | 10 Sqmm x 2 Core | 210 | RM | 200 ₹42,000 | 125 ₹26,250 Lowest | 125 ₹26,250 Lowest |
| 2.00 | Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved and tested Street Light TIme switch Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work ( made out of 40 mm X 40 mm X 6 mm thick ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035 embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm, The scope of work also comprising of the following:- ( Location:- ) Make of Panel Board:- Adlec/ Schneider / Universal Switch Gear Control/ Tricolite. | 1 | Each | 50,000 ₹50,000 Lowest | 2,18,074 ₹2,18,074 | 63,786 ₹63,786 |
| 2.01INSTRUMENTS:- (i) Red, Yellow, Blue Phase indicating light LED type- 01 Set. (ii) Control MCB 6 A SP C Series - 1 Set. INCOMING:- (i) MCB 63 Amps, 4 Pole, 10 KA, 50 Hz, 415 Volts-01 No. Make: L&T/ Havells / Legrand (ii) Power Contactor 3 Pole, 32 Amps. 50 Hz, 220 Volts- 01 No. Make: L&T/ Havells/ ABB or equivalent. (iii) Analog Time Switch electronic type, QT one dial daily with battery backup of 100 hours, Programmable every 4 Hours current capacity 16 Amps 240/415 Volts, 50 Hz- 01 No. Make: L&T/ Havells or equivalent. (iv) Auto Manual Selector Switch 6 A SP- 01 No. Make: L&T/Schneider/Kaycee. (v) RED Phase indicating light LED type- 01 No.. Make: L&T/Vishnu/ Schneider/ C&S. (vi) Outgoing Terminal 4 Way - 1 Set. Make: Master/FTC/Connectwell. Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring 10 Sqmm flexible. Note: In Case of failure, manual system should also be provided. | ||||||
| 2.02The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. | ||||||
| 3.00 | Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable in any type of soil and getting out complete all as specified & directed by Engineer-in-Charge. | 48.6 | Cum | 500 ₹24,300 | 486 ₹23,619.6 | 240 ₹11,664 Lowest |
| 4.00 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick all as specified & directed by Engineer-in-Charge.. | 15.6 | Cum | 100 ₹1,560 | 156 ₹2,433.6 | 70 ₹1,092 Lowest |
| 5.00 | Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. | 54.64 | Cum | 100 ₹5,464 Lowest | 546 ₹29,833.44 | 150 ₹8,196 |
| 6.00 | M & L Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & directed by Engineer-in-Charge. | 8.1 | Cum | 1,000 ₹8,100 | 810 ₹6,561 | 786 ₹6,366.6 Lowest |
| 7.00 | Taking out old unserviceable / serviceable class 'B' bricks from excavated trenches all as specied and directed by Engineer-In-Charge.
Note:- Serviceable class 'B' bricks kept in safe custody for reuse at site and unserviceable bricks to be through in low lying area. | 870 | Each | 2 ₹1,740 | 8.7 ₹7,569 | 1 ₹870 Lowest |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
7 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh K K Soni AE (Civ) AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR TO DECORATIVE LIGH GARDEN LIGHT AND MISC WORK AT DGRE RDC MANALI AT AGE(I) R and D, MANALI
2025_MES_713326_1
AGE(I)/MNL-35/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
DGRE RDC MANALI
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
AGE(I) R and D MANALI
₹19,800
Yes
7 Aug 2025
9 Jun 2025
15 Jul 2025
9 Jun 2025
7 Jul 2025
23 Jun 2025
Amount
Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size after taking down complete all as specified and directed by Engr-in-charge and directed as follows :
10 Sqmm x 2 Core
Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved and tested Street Light TIme switch Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work ( made out of 40 mm X 40 mm X 6 mm thick ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035 embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm, The scope of work also comprising of the following:- ( Location:- ) Make of Panel Board:- Adlec/ Schneider / Universal Switch Gear Control/ Tricolite.
The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable in any type of soil and getting out complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick all as specified & directed by Engineer-in-Charge..
Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & directed by Engineer-in-Charge.
Taking out old unserviceable / serviceable class 'B' bricks from excavated trenches all as specied and directed by Engineer-In-Charge. Note:- Serviceable class 'B' bricks kept in safe custody for reuse at site and unserviceable bricks to be through in low lying area.
Supply and laying old size sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable complete all as specified and directed by Engr-in-Charge
Laying only serviceable sub class ‘B’ bricks as retrieved from Srl item No 10 complete all as specified and directed by Engr-in-Charge.
M & L for Heat Shrinkable 1.1 KV XLPE Straight Joints of following size including taking down complete all as specified and directed by Engr-in-charge and directed as follows :
10 sqmm to 25 sqmm size
Arranging fault locating machine to locate the fault in underground electric power cable of any length & any type of 1.1 KV grade HT/ LT cables & pin point the fault, it also include testing of the cable after locating fault and cutting the cable at Fault to fix the joint including excavation and earth wotrk in any type of soil complete Note : Cable joint shall be measured and paid separately under respective of Sch 'A' (ii) If fault is not rectifed within 24 hours after receivng message , the contractor shall be charged penalty for Rs 500/- per Hours & the same has been deducred from his account during RAR
Supply & fixing in repair of moulded case circuit breaker four pole 25 to 100 amps 3 pole 16 KA Capacity 415V 50 Hz with adjustable thermal and magnetic relay incl replacement of lugs & disconnecting and taking out the old unservicable MCCB from panel/DBs/ etc complete all as specified and directed by Engr-in-charge and directed. (Make of MCCB's Legrand/Havells/L&T/C&S) as per site requirement.
M&L for painting of GI tubing pole for post top lantern/garden lights after Cleaning and scraping with wire brush complete with two coat of aluminium paint over a coat of red oxide primer and applying one coat of cement base paint on PCC coping complete all as directed
S&F decorative LED type post top(Cool Day white light) lanterns luminaire 25 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity complete with suitable driver all as specified.
S&F decorative LED type post top(Cool Day white light) lanterns luminaire 40 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity complete with suitable driver all as specified.
S&F LED bollard luminaire 10 watts, inverted pyramid tripod type with soft 360 degree light out door type having resistant to corrosion with better optics for uniform distribution complete with suitable driver & fixing nuts, bolts & washers all as specified.
S&F in replacement of LED fountain light luminaire 18 watts, ,underwater type ,12 V DC adjustable type IP 68 type complete with stainless steel housing toughened glass LED Lens as of approved colour temperature including fixing on existing surface with including suitable nuts , bolt& washer and making proper electrical connection complete all as specified
S&F in replacement of machined cast bronze natural finish fountain nozzle 15 mm PF 3452 type with cascade complete as specified Make : Aquascape /sant
M&L for cement concerete 1:4:8 type D2 ( using 40mm grade stone aggregate) cement concrete as in foundation filling and mass concrete for sub base of post top lantern/garden light poles all as specified and directed by Engineer-in-Charge.
M&L for cement concerete 1:3:6 type C2 ( using 20mm grade stone aggregate) cement concrete as in foundation filling for base of post top lantern/garden light all as specified and directed by Engineer-in-Charge.
M&L for cement concerete 1:2:4 type B1 ( using 12.5mm grade stone aggregate) cement concrete as in coping ofpost top lantern/garden light poles all as specified and directed by Engineer-in-Charge.
Supply, laying and testing galvanised steel tube (GI) light grade of size 40 mm (1.5") bore for standpost of post top/ garden lights all as specified and directed by Engineer -in-Charge.
M/s A.K. ENGINEERS (BID ID -3342020)
R. P. Suppliers and Construction Co. (BID ID -3346589)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .