Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.6 L+₹94,784 (8.91%)Rejected-AOC 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L2 | Rejected-AOC L2 |
Tender Value
₹10.6 L
EMD Value
₹26,590
Closing Date
9 Jun 2025, 6:00 pmClosed
Assistant Executive Engineer
o/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
DEPOSIT-AMC of Substation and Diesel Generator sets 2025-2026-Fully Comprehensive Annual Maintenance Contract for Substation and Diesel Generator sets at Govt Medical College Thrissur for the period from 01-04-2025 to 31-03-2026-General Electrical
2025_PWD_767704_1
ESDT(ET)32/AEE/25-26
Open Tender
Electrical Works
Item Rate
365 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹26,590
19 Jul 2025
3 Jun 2025
12 Jun 2025
3 Jun 2025
9 Jun 2025
3 Jun 2025
Amount
AMC DG set
OD10729/2024-2025:Service charge for carrying out periodical performance inspection, preventive maintenance, urgent repairs of of E/A set of 500 KVA capacity as per the standard maintenance scope & conditions, i/c labour charge for replacing minor faulty components of EA set / control panel / AMF panel etc...(excluding spares) Attending Emergency calls on Report, excluding cost of major maintenance works ( 12 service per year) Conditions of periodical services i Check Level And Top up a Oil in engine b Oil in air cleaner c Oil in FIP d Fresh water level in heat exchanger e Water / coolent in radiator f Electrolyte in battery ii Check Tightness Of a Battery terminal & apply Vaseline b Fan belt c Hose connections in cooling system d Fuel piping connections e Exhaust piping connections f Engine mountings g Engine drive unit coupling h Electrical connections at instrument panel iii Start And Run The Engine 10 Minutes a Check and recording RPM b Check and record oil pressure c Check battery charging d Check and record max.operating temperature iv Check Leak From a Fuel piping & injector high pressure lines b Exhaust manifold flange & connections c Engine oil filter and other areas v Checking And Rectification of all safety controls indication and alarms such as a Low lub Oil pressure guage b High cylinder head temperature cut off c High water temperature guage d over speed relay e low fuel alarm And indication vi Checking of battery charger and its functioning like auto cut off, overcharging, reverse polarity, ammeter and voltmeter fuses, and rectify if found faulty. vii a Checking of earth values b Replace engine lub oil c Replace oil filter (engine) (to be done with d ) d Replace oil & clean filter in air cleaner
OD10730/2024-2025:Service charge for carrying out periodical performance inspection, preventive maintenance, urgent repairs of of E/A set of 320 KVA capacity as per the standard maintenance scope & conditions, i/c labour charge for replacing minor faulty components of EA set / control panel / AMF panel etc...(excluding spares) Attending Emergency calls on Report, excluding cost of major maintenance works ( 12 service per year) Conditions of periodical services i Check Level And Top up a Oil in engine b Oil in air cleaner c Oil in FIP d Fresh water level in heat exchanger e Water / coolent in radiator f Electrolyte in battery ii Check Tightness Of a Battery terminal & apply Vaseline b Fan belt c Hose connections in cooling system d Fuel piping connections e Exhaust piping connections f Engine mountings g Engine drive unit coupling h Electrical connections at instrument panel iii Start And Run The Engine 10 Minutes a Check and recording RPM b Check and record oil pressure c Check battery charging d Check and record max.operating temperature iv Check Leak From a Fuel piping & injector high pressure lines b Exhaust manifold flange & connections c Engine oil filter and other areas v Checking And Rectification of all safety controls indication and alarms such as a Low lub Oil pressure guage b High cylinder head temperature cut off c High water temperature guage d over speed relay e low fuel alarm And indication vi Checking of battery charger and its functioning like auto cut off, overcharging, reverse polarity, ammeter and voltmeter fuses, and rectify if found faulty. vii a Checking of earth values b Replace engine lub oil c Replace oil filter (engine) (to be done with d ) d Replace oil & clean filter in air cleaner
OD10731/2024-2025:Service charge for carrying out periodical performance inspection, preventive maintenance, urgent repairs of of E/A set of 200 KVA capacity as per the standard maintenance scope & conditions, i/c labour charge for replacing minor faulty components of EA set / control panel / AMF panel etc...(excluding spares) Attending Emergency calls on Report, excluding cost of major maintenance works ( 12 service per year) Conditions of periodical services i Check Level And Top up a Oil in engine b Oil in air cleaner c Oil in FIP d Fresh water level in heat exchanger e Water / coolent in radiator f Electrolyte in battery ii Check Tightness Of a Battery terminal & apply Vaseline b Fan belt c Hose connections in cooling system d Fuel piping connections e Exhaust piping connections f Engine mountings g Engine drive unit coupling h Electrical connections at instrument panel iii Start And Run The Engine 10 Minutes a Check and recording RPM b Check and record oil pressure c Check battery charging d Check and record max.operating temperature iv Check Leak From a Fuel piping & injector high pressure lines b Exhaust manifold flange & connections c Engine oil filter and other areas v Checking And Rectification of all safety controls indication and alarms such as a Low lub Oil pressure guage b High cylinder head temperature cut off c High water temperature guage d over speed relay e low fuel alarm And indication vi Checking of battery charger and its functioning like auto cut off, overcharging, reverse polarity, ammeter and voltmeter fuses, and rectify if found faulty. vii a Checking of earth values b Replace engine lub oil c Replace oil filter (engine) (to be done with d ) d Replace oil & clean filter in air cleaner
OD10732/2024-2025:Service charge for carrying out periodical performance inspection, preventive maintenance, urgent repairs of of E/A set of 160 KVA capacity as per the standard maintenance scope & conditions, i/c labour charge for replacing minor faulty components of EA set / control panel / AMF panel etc...(excluding spares) Attending Emergency calls on Report, excluding cost of major maintenance works ( 12 service per year) Conditions of periodical services i Check Level And Top up a Oil in engine b Oil in air cleaner c Oil in FIP d Fresh water level in heat exchanger e Water / coolent in radiator f Electrolyte in battery ii Check Tightness Of a Battery terminal & apply Vaseline b Fan belt c Hose connections in cooling system d Fuel piping connections e Exhaust piping connections f Engine mountings g Engine drive unit coupling h Electrical connections at instrument panel iii Start And Run The Engine 10 Minutes a Check and recording RPM b Check and record oil pressure c Check battery charging d Check and record max.operating temperature iv Check Leak From a Fuel piping & injector high pressure lines b Exhaust manifold flange & connections c Engine oil filter and other areas v Checking And Rectification of all safety controls indication and alarms such as a Low lub Oil pressure guage b High cylinder head temperature cut off c High water temperature guage d over speed relay e low fuel alarm And indication vi Checking of battery charger and its functioning like auto cut off, overcharging, reverse polarity, ammeter and voltmeter fuses, and rectify if found faulty. vii a Checking of earth values b Replace engine lub oil c Replace oil filter (engine) (to be done with d ) d Replace oil & clean filter in air cleaner
OD10733/2024-2025:supply and replace the O- rings (spare) for 500 KVA
OD10734/2024-2025:supply and replace the O- rings (spare) for 160 KVA
OD10735/2024-2025:supply and replace Fuel pre-filter of the 160 KVA DG
OD10736/2024-2025:Supply and replace Fuel pre-filter of the 500 KVA DG
OD10737/2024-2025:Supply and replace filter Element of 160 KVA DG
OD10738/2024-2025:Supply and replace filter Element of 500 KVA DG
OD10739/2024-2025:Supply and Replace the Lub Oil Filter for 160 KVA DG
OD10740/2024-2025:Supply and Replace the Lub Oil Filter for 500 KVA DG
OD10741/2024-2025:Supply and replace Air filter Element complete set of 500 KVA DG
OD10742/2024-2025:Supply and replace Seal, O ring for 320 KVA DG
OD10743/2024-2025:Supply and replace Element Air cleaner 4055280 for 320 KVA DG
OD10744/2024-2025:Supply and replace Element Air Cleaner for 320 KVA DG
OD10745/2024-2025:Supply and replace theElement Lube Oil Filter for 320 KVA DG
OD10746/2024-2025:Supply and replace the super by pass Filter element for 320 KVA DG
OD10747/2024-2025:Supply and replace Filtter and ring for 320 KVA DG
OD10748/2024-2025:Supply and replace supper by pass filter for 200KVA DG
OD10749/2024-2025:Supply and replace fuel filter for 200 KVA DG
OD10750/2024-2025:supply and replace the Lube oil filter for 200KVA DG
OD10751/2024-2025:Supply and refill Engine Oil with buy back arrangement (15W-40)
OD10752/2024-2025:Supply, Installation, Testing and commissioning of AMF control unit in the place of existing damaged AMF make C & S or equivalent
OD10753/2024-2025:Charges for servicing LT panel board including checking general condition, checking earthing connection, checking operation of ACB/MCCB function, checking relay and settings , checking metering, checking control wiring, cleaning and tightening of incoming and out going connections of the breakers and accessories, bus bar, insulators etc Boards having total number of switch gear not less than 10 numbers
OD10754/2024-2025:Charges for servicing 1000kVA resin cast indoor transformer including bus trunking, checking general condition , checking earth leakage , Checking of electrical , manual , Closing & Tripping function, checking relay and settings, Checking LBS, checking temperature devices, checking metering, checking control wiring and cleaning and tightening of LT and HT side connections of the breakers and accessories, bus bar, insulators etc
OD10755/2024-2025:Charges for servicing 315kVA resin cast indoor transformer including bus trunking, checking general condition , checking earth leakage , Checking of electrical , manual , Closing & Tripping function, checking relay and settings, Checking LBS, checking temperature devices, checking metering, checking control wiring and cleaning and tightening of LT and HT side connections of the breakers and accessories, bus bar, insulators etc
OD10756/2024-2025:Charges for servicing VCB including checking general condition , Checking VCB Rack in Rack out function, checking earth leakage , Checking of electrical , manual , Closing & Tripping function , checking relay and settings , checking control wiring and cleaning and tightening of incoming and out going connections of the breakers and accessories etc
OD10757/2024-2025:Charges for servicing ACB including checking general condition , Checking ACB Rack in Rack out function, checking earth leakage , Checking of electrical , manual , Closing & Tripping function , checking relay and settings , checking control wiring and cleaning and tightening of incoming and out going connections of the breakers and accessories etc
OD10758/2024-2025:Supply installation Testing and commissioning of 12VDC 180AH heavy duty battery-Exide XP1800
POZITIVE POWER INDIA PVT LTD (BID ID -2222860)
Bidder Name
Biju E.M
POZITIVE POWER INDIA PVT LTD
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1251698.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .