Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.9 LRejected-Finance | ₹19.9 L | 1 | Rejected-Finance Rate Very High as compare to Estimate |
Tender Value
₹12.7 L
EMD Value
₹25,303
Closing Date
9 Nov 2022, 5:00 pmClosed
The DGM ED Kamalpur
O/o the DGM, ED Kamalpur, Dhalai Tripura 799285
Shifting of HT/LT line ,S/S for improvement/up-gradation of Kamalpur to Manikbhander road double lane under ED Kamalpur(Partial Turn-key)
2022_POWER_33227_1
DGM/KMP/E-TENDER/22-23/03(2nd Call) dt 26/10/2022
Open Tender
Electrical Works
Turn-key
180 days
ESD Kamalpur under ED Kamalpur
As per NIT
3 documents required · 3 mandatory
₹1,000
Yes
₹25,303
Yes
O/o the DGM ED Kamalpur
27 Apr 2023
27 Oct 2022
10 Nov 2022
27 Oct 2022
9 Nov 2022
3 Nov 2022
28 Oct 2022 - 2 Nov 2022
2 Nov 2022
Amount
(Supply) 11 KV Line and LT line overhead using ACSR Conductor as per technical specification & scope of work.
Supply of 9 m PCC Poles - (PCC Pole as per state practice)
Supply of 11 m STP Poles -(STP Pole as per state practice)
Supply of 9 m STP Poles - (STP Pole as per state practice)
Supply of 8 m STP Poles - (STP Pole as per state practice)
Supply of Fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc. made of MS channels (100X50x50X6MM), (75X40x40X6MM), MS angle (65X65X6MM), (50x50x6 mm ), MS flats (50x6mm) of given sizes for over head structures as per technical specification and scope of work.
Supply of galvanised MS Nuts, Bolts with Washers as per technical specification and scope of work.
Supply of Stay Set with 50x8 mm stay clamp, stay insulator (1 No.), anchor plate (300x300x8), nut bolts, 1 No turn-buckle, 1.8 mtr long, 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded stay wire complete as per technical specification and scope of work.
ACSR (weasel) 6/1/2.59mm
11 KV Polymeric Disc Insulator 45 KN along with suitable hardware fittings.
11 KV Polymeric Pin Insulator with GI Pin.
Shackle Insulator (3x3.5)'' for LT system with mechanical strength 16 KN confirming to ISS:-1445/1977 (2nd revision ammended) with supply of hot dip galvanized G.I Straps with bolts/ U-Clamp and nuts & bolts complete ( Suitable for Weasel conductor) as per technical specification and scope of work.
11 KV Distribution Class Lightening Arrester 9 KV/5 KA for DT as per technical specification and scope of work.
11 KV, 3-Ph, 200 A, 2 Post, Horizontal/Vertical Mounting type Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications and scope of works.
11 kV, 3-Ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, barrel fuse etc. complete as per technical specifications and scope of works.
4 Nos pipe earthing using 40mm dia GI pipe, 2500 mm long as per IS 1161, making earth grid using 50x6mm GI Flat and raiser as per scope of work of Distribution Transformer Sub-Stations as per technical specifications.
Dismentaling and refixing of the following
1 Phase/ 3 Phase/ Street light service connection dismentelling and re-connection of the same i.c supply of necessary additional PVC wire as required.
Up-rooting / Dismentalling of the following: -
08/09 mtr long S.T/ PCC, R.S. Joist and Rail pole etc.
Stay set complete in/c excavation of earth with full accessories etc as reqd.
ACSR (weasel/squirel/ ABC if any etc.) i.c coiling, stacking and handover to Sub-Divisional store.
LT shackle insulator/ pin insulator etc as required i.c storing, stacking and handover to Sub-Divisional store.
11KV Disc Insulator 45 KN along with suitable hardware fittings and Pin Insulator with GI Pin i.c storing, stacking and handover to Sub-Divisional store.
Fabricated old steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc made of MS channels (100X50x50X6 mm), (75X40x40X6 mm), MS angle (65X65X6 mm), (50x50x6 mm) and MS flats (50x6 mm) of given sizes for over head structures as per scope of work.
11 KV, 3-ph, 200 Amp, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete/ 11 KV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete with 11 KV Distribution Class Lightening Arrester for DT as per technical specification and scope of work i.c storing, stacking and handover to Sub-Divisional store.
11/0.4 KV, 100KVA Distribution transformer, in/c nacessary disconnection of HT/LT terminals from DTR re-wirable kit-kat fuse unit, earthing arrangement etc as directed by the Engineer-in-Charge.
Dismental and re-errection of 11KV, XLPE power cable, 185 sq mm in GI pipe/HDPE pipe for raiser i.c tie up of pipe with pole by the help of MS clamp etc as required as directed by the Engineer in charge.
Erection, testing and Commissioning 11 kV Line , LT line using ACSR Conductor and installation of distribution transformer
Erection of 11 m STP Poles for 11 KV /LT overhead line by Excavation of pole pit (of depth 1/6th of pole length) in soft rock and installing including cement concrete foundation or refilling by bolders using cement concrete foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth etc and grouting of STP with CC work (1:2:4) 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (0.24 Cum per pole) as per scope of work and specifications: - (STP Pole as per state practice)
Erection of 9 m PCC Poles for 11 KV /LT overhead line by Excavation of pole pit (of depth 1/6th of pole length) in soft rock and installing including cement concrete foundation or refilling by bolders using cement concrete foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work and specifications:- (PCC Pole as per state practice)
Erection of 9 m STP Poles for 11 KV /LT overhead line by Excavation of pole pit (of depth 1/6th of pole length) in soft rock and installing including cement concrete foundation or refilling by bolders using cement concrete foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth etc and grouting of STP with CC work (1:2:4) 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (0.24 Cum per pole) as per scope of work and specifications: - (STP Pole as per state practice)
Erection of 8 m STP Poles for 11 KV /LT overhead line by Excavation of pole pit (of depth 1/6th of pole length) in soft rock and installing including cement concrete foundation or refilling by bolders using cement concrete foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work and specifications: - (STP Pole as per state practice)
Erection of complete stay set i.c excavation of stay pit with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications and scope of works.
Erection, testing and commissioning of 11 KV Polymeric Disc Insulator 45 KN along with suitable hardware fittings .
Erection, testing and commissioning of 11 KV Polymeric Pin Insulator with GI Pin.
Erection, testing and commissioning of Shackle Insulator (3x3.5)'' for LT system with mechanical strength 16 KN confirming to ISS:-1445/1977 ( 2nd revision ammended) with supply of hot dip galvanized G.I Straps with bolts/ U-Clamp and nuts & bolts complete ( Suitable for Weasel conductor) as per technical specification and scope of work.
Erection, testing and commissioning of 100 KVA 3 phase Aluminium / Copper wound DTR
Erection, testing and commissioning of 04 Nos pipe earthing using 40mm dia GI pipe 2500 mm long, as per IS 1161, making earth grid using 50x6mm GI Flat and raiser and connecting raisers to various equipment as per scope of work and technical specifications.
11 KV Distribution Class Lightening Arrester 9 KV/5 KA for DT as per technical specification and scope of work.
11 kV, 3-ph, 200 A, 3 Pin type, Horizontal/Vertical Mounting type Gang operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications and scope of works.
11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications and scope of works.
Erection of fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, strain plate, guarding channels, back clamp, transformer mounting structure, 2/4/5wire LT line bracket, C-type bracket etc. made of MS channels (100X50x50X6MM), (75X40x40X6MM), MS angle (65X65X6MM), ( 50x50x6 mm), MS flats (50x6mm) of required sizes for over head structures as per technical specification and scope of work.
Laying, stringing of ACSR weasel Conductor 6/1/2.59mm i.c hoisting, binding, jumpering etc. as required as per technical specification and scope of work.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .