Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹18.1 L+₹66,905 (3.85%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹20.1 L+₹2.7 L (15.3%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹20.1 L+₹2.7 L (15.7%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹24.4 L+₹7.0 L (40.1%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Rejected being |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 May 2024, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE(N)AMB-12/2024-25 REWIRING OF INTERNAL ELECTRIFICATION INCLUDING ALLIED WORKS IN OTM ACCN AND OTHER AREA-I OF SECTOR A OF AGE E/M UNDER GE (N) AMBALA CANTT
2024_MES_648553_1
GE(N)/AMB-12/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (N) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹90,000
Yes
2 Sept 2024
30 Mar 2024
23 May 2024
30 Mar 2024
21 May 2024
7 May 2024
30 Mar 2024 - 7 May 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description all as per serial item No.02 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description all as per srl item No 02 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair electronic Fan regulator modular 100 watt, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply only LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply only LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, indoor decorative LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient aluminium housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair LED batten fitting 10-12 watt, 2 feet, PVC housing with electronic driver including tube rod 10/12 watt cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, PVC housing, surge protection including driver and LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, 9/12 watt LED light fitting wall mounting wooden fixture (sketch type) including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable light fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, recess mounting LED 15/18 watt cool/warm type circular down lighter/ COB panel with PVC housing, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with 3 core flexible copper conductor from ceiling rose to connector of the light, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, recess mounting LED 5/8 watt cool/warm type circular down lighter/ COB panel with PVC housing, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with 3 core flexible copper conductor from ceiling rose to connector of the light, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 20 -25 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver, service bracket of mild steel pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED flat panel 2' x 2' size fully diffused surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable from ceiling rose to light fitting as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED Flood lights, 100 watt, IP-66, aluminium die cast housing with unique lens system and toughened glass with gasket 240 volt, 50Hz, AC supply complete with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED Bollard 8-10 watt, IP-65 , 6500 K luminaire made of pressure die cast aluminium housing and clear glass , 240 volt, 50HZ, AC supply , complete with all accessories including electronic driver, internally pre wired including connecting with three core flexible copper conductor cable from Electric Supply Source to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED post top luminaire 20W- 25W, 5700K, IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories, including electronic driver, internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of the light, including disconnecting and taking down existing light fitting and removing old unserviceable fitting complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED high bay/medium bay luminaire 80-90 watt, IP-65,indoor type input voltage range 120-270 volts including electronic driver, provision of 3 core copper conductor cable 1.5 Sqmm size from connector/ceiling rose to fitting with fixing arrangement as per site requirement/conditions, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, sheet metal enclosure Vertical triple pole & neutral(VTPN) with MCCB 100 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, sheet metal enclosure triple pole & neutral(TPN) with MCB 63 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, MCB DB SPN 2 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, MCB DB SPN 12 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB SPN, 6-40 Amps, 240 volt,10 KA, 'B' curve, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB SP, 6-32 Amps, 240 volt,10 KA, 'B' curve ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB SPN, 63 Amps, 240 volt,10 KA, 'B' curve ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB three pole and neutral, 415 Volts, 63-100 Amps, 16 KA, 50 Hz ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked, multi stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade, ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked, multi stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade, ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED batten fitting 18-20 watt, 4 feet, PVC housing cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair PCB unit suitable for BLDC ceiling fan of 1200mm sweep single phase, 240 volts, of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 3 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 4 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 6 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 8 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, MCCB, 4 pole , 63 Amp, 415 Volts, 16 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, MCCB, 4 pole , 100 Amp, 415 Volts, 25 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting electric/water supply connection, taking down carefully geyser of any capacity and of any description, depositing to MES store yard for repair and refixing the same after repair in the same location or another location complete all as specified and directed by Engineer-in-Charge.
Supply and replacing inner tank made from 1mm thick stainless steel sheet for geyser of 50 Litre capacity including taking out old unserviceable inner tank complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacing inner tank made from 1mm thick stainless steel sheet for geyser of 25 Litre capacity including taking out old unserviceable inner tank complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, heating element cup or triangle type of 2 KW as required at site for geyser of any make and any descriptions all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, thermostat switch for geyser of any type, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, geyser inner tank assembly suitable for geyser capacity of 25 Litre complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, geyser inner tank assembly suitable for geyser capacity of 50 Litre complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, brass chromium plated non return valve 15mm bore with air lock release arrangement, ISI Marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, metal clad socket top as per existing socket complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement flexible cable PVC insulated and sheathed, 3 core, circular multi stranded copper conductor of 1.50 Sqmm complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair PVC connection pipe 450mm long having wire mesh coating over it with brass nuts and washers suitable for connecting geysers inlet and outlet to GI tubing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair PVC connection pipe 600mm long having wire mesh coating over it with brass nuts and washers suitable for connecting geysers inlet and outlet to GI tubing complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling/exhaust/wall mounted/pedestal fans of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections and deposit at fan store of AGE E/M north for issuing of fan to contractor for repair, and collecting the fan after repair and hanging the same at location as directed by the concerned JE E/M complete all as specified and as directed by the Engineer-in-Charge.
Supply, fixing and testing water heater (Geyser) metal outer body with stainless steel tank of capacity 25 ltrs including all accessories like, NRV, heavy duty PVC Connection and making good to surface area with new hold fasterner connection complete all as specified and directed by Engineer-in-Charge.
Material and labour for opening the stator & rotor of the 1200mm sweep ceiling fan, cutting the existing worn winding and rewinding the fan with superior quality copper wire and filling the varnish as insulation between each winds & covering each loops of winding by sleeves and paper & reassembling of complete fan by fixing serviceable old and new parts of fans i.e. rubber bush, condenser and shackle housing , gun metal bushes, ball bearings, twin twisted copper cable, down rod assembly & canopy ,split pins complete all as per manufacturers design air delivery including greasing, oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep. Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid wide relevant items of the schedule. (ii). The rates for refixing and taking out serviceable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No on fans (v). Unserviceable /defective retrieved parts shall be credited vide sch of credit. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans shall be repaired/rewind at AGE E/M store yard only.
Description all as per serial item No 65 here-in-before but for Exhaust fans of 225/250mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Description all as per serial item No 65 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Description as per serial item No 65 here-in-before but for Exhaust fans of 450mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Supply only GI 'D' clamp heavy duty of superior quality and nut and bolts with locking arrangement complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing heavy duty exhaust fan 250mm sweep with corrosion resistant steel body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, steel base frame with rubber mountings for silent operation, 6 pole, maximum watt input not more than 37 watt, 1100 RPM, minimum air delivery 810 cum/hour with metal blades and shutter type louvers self-openable/ closable for protecting the entrance of birds as per IS :2132-1967 and testing including taking down old unserviceable exhaust fan complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cleaning the fan motor assembly body, blade of ceiling fan, filling the cavity, rubbing with sand paper, taking off old paint with the help of chemicals and painting the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint including writing the MES number on the ceiling fans of 1200mm sweep with black colour synthetic enamel paint including greasing complete all as specified and as directed by the Engineer-in-Charge.
Description as per serial item No 71 here-in-before but for Exhaust fans of 250/300mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Description as per serial item No 71 here-in-before but for Exhaust fans of 450mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Supply only bearing for 1200/1400mm sweep ceiling fans , complete all as specified and as directed by the Engineer-in-Charge.
Supply only bearing for 250 to 450 mm sweep Exhaust fans, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing round clamp of suitable size for hanging of 1200-1400 mm ceiling fans in 40/50 mm GI pipe, as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan ,complete all as specified and as directed by the Engineer-in-Charge.
Material and labour in repair for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron. Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing, complete all as specified and as directed by the Engineer-in-Charge.
Supply only capacitor 2.5 MFD for ceiling fan of any description complete all as specified and as directed by the Engineer-in-Charge.
Supply only capacitor 3.15 MFD dry type complete all as specified and as directed by the Engineer-in-Charge.
Supply only flexible cable PVC insulated and sheathed, 2 core, circular multi stranded copper conductor of 23/0.076 Sqmm including removing unserviceable cable, complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc. or for shafts, wells, manholes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Supply and Laying or fixing or passing through pipe for cable XLPE insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade 4 core of size 16 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying GI tubing light grade with connected fittings laid in trenches/wall/ pole for protection to UG cables of size 40 mm dia. complete all as specified and as directed by the Engineer-in-Charge.
Material and labour dry sand cushioning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Material and labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material or soil to a distance not exc. 50m and depositing where directed complete all as specified and as directed by the Engineer-in-Charge.
Supply only down rod 60cm long made out of 15/12 mm bore light grade GI /MS pipe having provision of fixing U clamp and Fan including painting the pipe with superior quality white colour synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair heavy duty wall mounting fan 400 mm sweep with corrosion resistant PVC body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, rigid frame , 1400 RPM, PVC blades and testing complete all as specified and as directed by Engineer-in-Charge.
Note:- Amount of credit of Rs. 1,35,106.00 for retrieved materials is mentioned in Schedule of Credit Page No. 97 (R) to 98 (R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
Saurav Enterprises
R N Enterprises
Mohinder Pal and Sons
M/S Sonu Traders
gurchan singh & sons.
M/s Prakash Enterprises
S.R. Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .