Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 CrAccepted-AOC MIG 2B 83 H NO 65 5 466 GULLAPALEM SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹8.3 Cr | L1 | Accepted-AOC Accepted being workable and reasonable rates are quoted by bidders |
| 2 | L2₹8.9 Cr+₹56.0 L (6.74%)Rejected-Finance | ₹8.9 Cr+₹56.0 L (6.74%) | L2 | Rejected-Finance Being Not L1 |
| 3 | L3₹8.9 Cr+₹56.5 L (6.81%)Rejected-Finance | ₹8.9 Cr+₹56.5 L (6.81%) | L3 | Rejected-Finance Being Not L1 |
| 4 | L4₹9.0 Cr+₹66.4 L (8.01%)Rejected-Finance | ₹9.0 Cr+₹66.4 L (8.01%) | L4 | Rejected-Finance Being Not L1 |
| 5 | L5₹9.0 Cr+₹69.5 L (8.38%)Rejected-Finance D NO 55 41 18 1 DOCTOR S COLONY SEETHAMMADHARA VISAKHAPATNAM PIN 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹9.0 Cr+₹69.5 L (8.38%) | L5 | Rejected-Finance Being Not L1 |
| Sl No | Description | Qty | Unit | SUMA ENCON PROJECTS PRIVATE LIMITED H2 | SRI SURYA PROJECTS H10 | S V S ENTERPRISES H7 | Sowrya Constructions H9 | VENKATA SAI SRINIVASA CONSTRUCTIONS PRIVATE LIMITED H8 | PJR PROJECT CONSTRUCTIONS PRIVATE LIMITED H5 | anjaliinfratech H1 | SVS PROJECTS H4 | ANANDA PROFILES PVT LIMITED H3 | PMR CONSTRUCTIONS H6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil, including removal of the rubish outside MD land, complete all as specified and as directed by the Engineer-in-Charge. | 229.6 | Square Meter | 42 ₹9,643.2 | 80 ₹18,368 | 34 ₹7,806.4 | 50 ₹11,480 | 45 ₹10,332 | 20 ₹4,592 Lowest | 80 ₹18,368 | 59 ₹13,546.4 | 35 ₹8,036 | 30 ₹6,888 |
| 1.00 | Excavation over areas not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. | 650 | Cubic Metre | 325 ₹2,11,250 | 350 ₹2,27,500 | 376 ₹2,44,400 | 320 ₹2,08,000 | 355 ₹2,30,750 | 250 ₹1,62,500 Lowest | 500 ₹3,25,000 | 329 ₹2,13,850 | 345 ₹2,24,250 | 350 ₹2,27,500 |
| 1.00 | Excavation over areas exceeding 1.5m in depth but not exceeding 3.00 m depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. | 237.23 | Cubic Metre | 375 ₹88,961.25 | 450 ₹1,06,753.5 | 439 ₹1,04,143.97 | 450 ₹1,06,753.5 | 500 ₹1,18,615 | 300 ₹71,169 Lowest | 600 ₹1,42,338 | 329 ₹78,048.67 | 490 ₹1,16,242.7 | 450 ₹1,06,753.5 |
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/loose soil, for foundation etc., or for shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified. | 469 | Cubic Metre | 275 ₹1,28,975 | 350 ₹1,64,150 | 439 ₹2,05,891 | 290 ₹1,36,010 | 450 ₹2,11,050 | 250 ₹1,17,250 Lowest | 400 ₹1,87,600 | 329 ₹1,54,301 | 375 ₹1,75,875 | 400 ₹1,87,600 |
| 1.00 | M&L for Moorum/Red bajri filling brought from out side MD land including filling in floors or pavings or in foundations laid in layers n.exc. 25cm thick spread, levelled and rammed including watering, complete all as specified and as directed.
Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. | 117.25 | Cubic Metre | 1,150 ₹1,34,837.5 | 1,150 ₹1,34,837.5 | 1,249 ₹1,46,445.25 | 890 ₹1,04,352.5 Lowest | 1,000 ₹1,17,250 | 1,150 ₹1,34,837.5 | 1,600 ₹1,87,600 | 1,499 ₹1,75,757.75 | 1,100 ₹1,28,975 | 1,200 ₹1,40,700 |
| 1.01 | M&L for Hardcore of gauge not exc. 63 mm, broken stone or boulders, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. | 35.48 | Cubic Metre | 2,510 ₹89,054.8 | 2,600 ₹92,248 | 2,779 ₹98,598.92 | 2,100 ₹74,508 Lowest | 2,600 ₹92,248 | 3,000 ₹1,06,440 | 2,100 ₹74,508 Lowest | 3,029 ₹1,07,468.92 | 2,550 ₹90,474 | 2,500 ₹88,700 |
| 1.01 | Removal of excavated material [Soil] to a distance exceeding 5KM but not exceeding 15KM and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. | 745.73 | Cubic Metre | 700 ₹5,22,011 | 1,000 ₹7,45,730 | 799 ₹5,95,838.27 | 1,200 ₹8,94,876 | 1,150 ₹8,57,589.5 | 700 ₹5,22,011 | 400 ₹2,98,292 Lowest | 689 ₹5,13,807.97 | 1,050 ₹7,83,016.5 | 1,100 ₹8,20,303 |
| 1.01 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any kind of soil, complete all as specified.
Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. | 286.74 | Cubic Metre | 175 ₹50,179.5 | 200 ₹57,348 | 133 ₹38,136.42 | 200 ₹57,348 | 185 ₹53,046.9 | 205 ₹58,781.7 | 250 ₹71,685 | 167 ₹47,885.58 | 180 ₹51,613.2 | 120 ₹34,408.8 Lowest |
| 1.01 | Material & labour for drilling or boring 600 mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/ loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) with hydraulic rigs with power unit upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials to a distance exc. 10 km and n.exc 15km and depositing where directed complete all as specified and as directed by Engineer-in-Charge. | 352 | Running Metre | 2,750 ₹9,68,000 | 2,500 ₹8,80,000 | 2,869 ₹10,09,888 | 2,900 ₹10,20,800 | 2,450 ₹8,62,400 | 3,560 ₹12,53,120 | 2,000 ₹7,04,000 Lowest | 2,399 ₹8,44,448 | 2,550 ₹8,97,600 | 2,600 ₹9,15,200 |
| 1.01 | All as per Item No.1.009 here-in-before but through hard rock for founding depth shall be 2D(Where D is dia of pile) or upto 1.5m depth whichever is higher for 600 mm nominal dia piles complete.
Notes for Item Nos. 1.009 & 1.010:-
(i) The depth of boring for piles shall be measured from existing ground/sea bed level/river bed top (as per soundings/reduced levels taken at the commencement of work) to the approved founding level.
(ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. The distance mentioned in description of item shall be the shortest distance from the centre of the building.
(iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his own cost after clearing all bentonite cakes.
(iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. | 14.4 | Running Metre | 5,000 ₹72,000 | 5,000 ₹72,000 | 2,869 ₹41,313.6 | 4,000 ₹57,600 | 5,700 ₹82,080 | 5,650 ₹81,360 | 2,600 ₹37,440 Lowest | 4,019 ₹57,873.6 | 5,650 ₹81,360 | 5,400 ₹77,760 |
Tender Value
₹7.7 Cr
EMD Value
₹7.1 L
Closing Date
9 Jan 2026, 6:00 pmClosed
Brig Sushil Kumar DDG CE
DDG and CE DGNP Naval Base Post Visakhapatnam 530014
AUGMENTATION OF TEST BED FACILITIES AT BUILDING NO.29
2025_MES_741674_1
DDG CE V TOKEN 07 OF 2025- 2026
Open Tender
Civil Works
Item Rate
365 days
Visakhapatnam
As per NIT
8 documents required · 8 mandatory
₹3,000
DGNP
₹7.1 L
Yes
DDG and CE Conference hall
15 Apr 2026
26 Nov 2025
16 Jan 2026
26 Nov 2025
9 Jan 2026
31 Dec 2025
26 Nov 2025 - 9 Dec 2025
10 Dec 2025
SCHEDULE "A" (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
Supply, laying, testing & commissioning in cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm , 3.5 Core all as specified and directed by Engr-in-Charge. Note: Earth work will be measured and paid separately.
PER LOAD
Removal of excavated material [Soil] to a distance exceeding 5KM but not exceeding 15KM and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified.
Supply, laying, testing & commissioning in cable insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. mm , 3.5 Core all as specified and directed by Engr-in-Charge. Note: Earth work will be measured and paid separately.
Material & labour for drilling or boring 600 mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/ loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) with hydraulic rigs with power unit upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials to a distance exc. 5 km and n.exc15km and depositing where directed complete all as specified and as directed by Engineer-in-Charge.
M&L for fabrication of LT Cubicle indoor type, factorymade, compartment type,type tested panel with CRCA sheet of 3.15 mm thick as per relevent IS, suitable for 3 phase, 4 wire system, including provision of 2 Nos spare compartments (for future planing work), suitable capacity Almunium busbar, having 1.5 times bearing capcity of main incoming switch gear ,digital metering eqpt etc panel, complete all as specified with following:- Incoming :- (a) 630A ACB 50 KA manual drawout type Suitable for 415V -01 Nos. Outgoing:- (a) 200A MCCB 35 KA Adjustable thermal and fixed magnatic type-01 No. (b) 100A MCCB 25 KA Adjustable thermal and fixed magnatic type -06 No. (c) Digital Ammeter & Voltmeter for incomming & outgoing. (d) LED indication lamp for RYB for in-coming indication. (e) LED indication lamps for breaker ON/OFF indications. (f) Multi functional meter
Chipping of laitance concrete in piles above cut off level up to a maximum of 1m from cut off level using suitable tools and equipments and dressing the pile head suitably so as to receive the form work for deck work, including breaking to the required level exposing the pile reinforcement to sufficient length as per approved drawing for embedding into the deck slab etc., and disposal of the debris to distance exc. 5Km but n. exc. 15Km complete all as specified and directed by the Engineer-in-Charge.
Material and labour for PCC (1:4:8) type D-2 using 40mm grade aggregate as in foundations, lean concrete underneath pile caps, capping beams, suspended floor, plinth beams, haunching and packing of pipes etc complete all as specified and as directed by Engineer-in-charge.
(vii) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made. (viii) Standard manufactured cover blocks as per IS should be used, Site cast cover blocks shall not be used. (ix) Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate/Lumpsum price quoted shall be deemed to include this aspect.
Supply and fix Mild steel bolts of dia n.ex 12 mm any type purpose made with hexagonal or square head one end and screwed the other, or screwed both ends;each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed by Engineer-in-charge.
Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced Ready Mixed Cement Concrete M–35 Design Mix with admixture Auramix 400 of Fosroc or Smartcare maximo plast PX range of Asian Paints or equivalent, as in Foundations including Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns etc., complete all as specified and as directed.
M&L for Reinforced Ready Mixed Cement Concrete M–35 Design Mix with admixture Auramix 400 of Fosroc or Smartcare maximo plast PX range of Asian Paints or equivalent, as in beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs and the like, complete all as specified and as directed.
Chip off, removal the existing plastering and loose concerete with hammer and chasels & using chipping machines wherever necessary including tools and machineries & labour charges etc complete all as specified and as directed by Engineer-in-Charge.
Providing and fixing the sacrificial anode GALVASHIELD XP or equinvalent over the main rainforcement of the column, beam and sun shades rainforcement at 1 No for 1 Sqm radius for sun shades and 1 No. for 1m ht. for column, as per the manufacturer specification. As sacrificial anodes protect the reinforcement against the corrosion complete all as specified and as directed by Engineer-in-Charge.
Clean the old and new reinforcement properly using wire brushes and applying anticorrosive coat NITOZINC PRIMER including materials and labour charges etc complete all as specified and as directed by Engineer-in-Charge.
M&L make the concrete surface neat & clean and applying the bonding agent NITOBOND EP over the concrete sruface to make the bond with new concrete including materials and labour charges etc complete all as specified and as directed.
M&L for making tight form work to the necessry size for the Microconcerting including material and labour etc complete all as specified and as directed by Engineer-in-Charge.
M&L for pouring microconcreting RENDEROC RG for 50-75mm thick with in 12mm below grade chips and reqiured water including materials, tools and labour charges etc complete all as specified and as directed by Engineer-in-Charge.
M&L for applying curing compound NITOBOND AR on the Microconcerete surface after removal the form work including materials, tools and labour charges etc complete all as specified and as directed by Engineer-in-Charge.
M&L for applying Protective coat DECKGUARD after the curing compound application over micro concrete surface including materials, tools and labour charges etc complete all as specified and as directed by Engineer-in-Charge.
M&L Cement concrete 50 mm, thick type B-1, 1:2:4 ( using 20mm graded aggregate) as in floor surfaces even and smooth complete all as specified and as directed by Engineer-in-charge.
M&L Cement concrete 75 mm, thick type B-2, 1:2:4 ( using 40mm graded aggregate) as a sub flooring/ sub-base to hard standing even and rough to receive the topping layer complete all as specified and as directed by Engineer-in-charge.
M&L For Cement concrete 25 mm, thick type B-0, 1:2:4 (using 12.5mm graded aggregate) even and rough to receive the topping layer complete all as specified and as directed by Engineer-in-charge.
Supply and laying Toilet paper holder coloured of vitreous china box type fixed to walls with chromium plated brass screws, complete all as specified and as directed.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in hard/dense soil, including removal of the rubish outside MD land, complete all as specified and as directed by the Engineer-in-Charge.
Excavation over areas not exceeding 1.5m in depth and getting out in s
Material and labour for coloured Glazed ceramic tiles 450 mmx 300mm x7mm thick for work on vertical surface such as skirting/dados, risers to steps etc, set and jointed in neat cement slurry and pointed in coloured cement to match with the tiles over and including 10mm thick plastering in cement mortar 1:4, complete all as specified and directed Engineer-In-Charge.
Material and labour for laying machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 20 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for laying 20-25 thickness Kota Stone with mirror polish in riser of steps, skirting, dado laid over mortar base in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
oft/loose soil complete all as specified and as directed by Engineer-in-charge.
M&L for 22 mm wide Aluminium dividing strips, 1.5mm thick, inserted in position, conform to design complete all as specified and directed Engineer-In-Charge.
Quintal
M&L for 50mm thick vaccum dewatered concrete flooring using M-20 grade design mix by vaccum processing with use of suction mat and vaccum pump and trowelling the surface with skim floater includig sprinkling floor hardner @ 5 Kg/Sqm over concrete surface while it is green and the surface finished mechanically even and smooth complete all as specified and directed Engineer-In-Charge.
Notes for Item Nos. 1.010 & 1.011 (contd..) (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in particular specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required (vi) The size of cutting tool shall not be less than diameter of pile by more than 75mm. (viii) Rate shall be inclusive of collecting Core samples from 5% of total no of pile and tested for crushing strength all as specified and as directed by Engineer-in-charge.
M&L for Hardcore of gauge not exc. 150mm, broken stone or boulders, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
All as per Item No.1.010 here-in-before but through hard rock for founding depth shall be 2D(Where D is dia of pile) or upto 1.5m depth whichever is higher for 600 mm nominal dia piles complete. Notes for Item Nos. 1.010 & 1.011:- (i) The depth of boring for piles shall be measured from existing ground/sea bed level/river bed top (as per soundings/reduced levels taken at the commencement of work) to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. The distance mentioned in description of item shall be the shortest distance from the centre of the building. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his own cost after clearing all bentonite cakes. (iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid.
M & L for 100 mm thick PCC 1:2:4 type B1 usisng 20 mm graded stone aggregate as in floor, surface finished even and fair complete all as specified and as directed by Engr -in-Charge.
M & L for 100 mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base etc, complete all as specified and as directed
M & L for 50 mm thick PCC 1:2:4 type B1 usisng 20 mm graded stone aggregate as in floor and spike rolling to floor surface or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed by Engr -in-Charge.
M & L for 150 mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base etc, complete all as specified and as directed
Steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.by Engineer-in-Charge.
Steel formwork to sides of pillars, posts, struts, columns, stanchions and the like, for fair finished surfaces of concrete, complete all as specified and as directed.
Steel formwork to sides and soffits of floor or roof beams, cantilevers, bressummers, lintels, shelves, lintel beams, RCC bands, girders etc complete.
Steel formwork to to Soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.by Engineer-in-Charge.
Steel formwork to faces of walls, retaining walls, abutments, parapets, vertical wall and staircase railings and similar work including attached pilasters, buttresses, etc, vertical or to batter for rough finished surface of concrete complete all as specified and as directed by Engineer-in-charge.
Material and Labour for reinforcement in any situation using Corrosion resistant TMT steel bars of grade Fe-500D, 10mm dia. and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for reinforcement in any situation using Corrosion resistant TMT steel bars of grade Fe-500D, 5mm dia and over as in stirrups, helicles, spacers and binders. bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for 38 mm wide Alumi
M&L Framed work such as grills, gratings, rungs etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder, framed baluster, walk ways, railings, and similar work confirming to Gde Fe-250 Quality B, complete all as specified and as directed.
Supply and Fixing of Plates (plain or chequered) channels, ISMBs, joists, angles etc square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410- WB(Gde- E-250) quality- B/BR all as per drawing and complete all as specified and as directed by Engineer-in-charge.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified.
Supply and fix Mild steel bolts of dia exc 12 mm and n.ex 20mm any type purpose made with hexagonal or square head one end and screwed the other, or screwed both ends;each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed by Engineer-in-charge.
Material and labour for providing and installing MS liner confirming to FE 410-WB grd E250 quality B/BR for bored cast -in-situ concrete piles with necessary stiffners, driving shoe with continuous welding including cutting bending welding etc. complete all as per specification and directed by engineer-in charge. Notes:- (i) Rate shall be inclusive of cutting the liner at cut off level. The rate is deemed to include for cutting, removal and salvage value of the material so obtained. (ii) MS liner shall be driven upto refusal level/12 Mtrs. from cut off level whichever is less irrespective of what is shown in the drawing, the occurance of diffuser level be decided by GE at the site based on visual inspection of bailer samples from pile bore hole, past experience and laboratory test result. The decision of GE in this regard will be final and binding. (iii) MS liner will be measured and paid up to the cut off level of pile only. Additional MS liner if used for convenience of construction shall be included in the rates quoted. No extra shall be paid separately on this account.
Material and Labour for Steel rolling shutters, with ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer;erected in position as indi cated, complete:gear operated type with bevel gear box and crank handle Thickness of laths in 12.5 mm complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Ball bearing for rolling shutters complete all as specified and as directed by Engineer-in-charge.
S&F electric motor of capacity 5KW including all necessary fitting for rolling shutters complete all as specified.
M&L for Reinforced Ready Mixed Cement Concrete M–40 Design Mix with admixture, as in Piles, including necessary dewatering, formwork, concrete mixed in RMC plant, transporting, placing, compacting, vibrating etc., complete all as specified and as directed. Notes: (i) Design mix shall be as per IS-456-2000 and the slump shall be 150 to 180mm. (ii) Reinforcement shall be measured and paid separa
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engineer-in-charge.
tely. (iii) Unit rate shall be deemed to include interalia for preliminary design mix, works test cubes as specified. (iv) Minimum cement content shall be 400 Kg/ Cu.m. of concrete using PSC with minimum slag content of 50% (fifty percent) (v) Admixture shall be added as per manufacturer instructions. The rate for Admixture shall be deemed to be included in the quoted rate. (vi) The unit rate shall be deemed to include for carrying out non-destructive integrity test for 100% of the total number of piles as per IS 14893-2001 shall be done by Govt Engineering College / NIT/IIT in the presence of contractor and the test results shall be vetted by the same authorities. Cost of testing is include in the quoted rates.
Notes :- (i) Minimum cement content shall be 400 Kg/Cu.m. of concrete for pile caps, suspended floor beams, slabs and footings, platform (Covered under item No.1.020 & 1.021) and shall be 340 Kg/Cu.m .of concrete for M-40 using Portland slag cement with minimum slag content of 50% (fifty percent) for items covered under item Nos. 1.022 to 1.023. (ii) Design mix shall be as per IS-456-2000. Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mm to 100mm and maximum water cement ratio 0.4. (iii) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes. iv) Reinforcement shall be measured and paid for separately. (v) In case at the time of mix design cement content is increased beyond minimum content given no extra payment will be made. (vi) Standard manufactured cover blocks as per IS should be used, Site cast cover blocks not be used (vii) Admixture shall be added as per manufacturer instructions. The rate for Admixture shall be deemed to be included in the quoted rate.
Providing precast cement concrete 1:2:4 type B0 as in louvres and jallies,45mm thick (measured solid), including all mouldings ,excluding frame Set in cement mortar Set in cement mortar 1:4 complete all as specified and as directed.
M&L for preparation of new or previously untreated surface of steel or steel based surface of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paints over a coat of zinc chroomate primer complete all as specified and as directed by Engineer-in-charge
M&L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
M&L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
Suppl
y and fix for 4 mm thick sheet glass ordinary quality, glazing with and including rubber gasket not exc 0.50 Sqm each pane complete all as specified and as directed by Engineer-in-charge.
Supply and fix 4 mm thick sheet glass ordinary quality, glazing with and including rubber gasket exc 0.50 Sqm each pane complete all as specified and as directed by Engineer-in-charge.
Supply and for Prelaminated particle board of 12 mm thick , exterior grade, prelaminated on both side with decorative choice complete complete all as specified and as directed by Engineer-in-charge.
Supply and fix for 125mm size type Butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed by Engineer-in-charge.
S&F for 125mm long aluminium anodised barrel tower bolt complete all as specified and as directed by Engineer-in-charge.
S&F for 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engineer-in-charge.
S&F 150mm size extruded aluminium alloy handles, fabricated type complete all as specified and as directed by Engineer-in-charge.
S&F 100mm size, 4 lever, brass mortice lock, vertical type complete all as specified and as directed by Engineer-in-charge.
S&F 250 mm alloy, anodised sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section and fixed complete all as specified and as directed by Engineer-in-charge.
S&F aluminium (extruded section body) door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S&F Floor door stopper with rubber shoe 150mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed complete all as specified and as directed.
S&F Factory made solid PVC door frame of size 50 mm x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply and fix in openings as per drawing complete all as specified and as directed by the Engineer-in-Charge
S&F Factory made solid panel PVC door shutter 30 mm thick consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame including builders hardware as per specification & drawing complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with Fly Ash Bricks, straight or curved on plan exceeding 6m mean radius, using modular bricks built in Cement Mortar 1:6, complete all as specified and directed.
Material and labour for Chequered cement concrete tiles 20cm x 20cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors laid over and including 15mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed by the Engineer-in-Charge.
M&L for Brick work using fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 including supply and fix 2 Nos of 8mm dia bars at every fourth course of brick work, complete all as specified and as directed.
Material and labour for Forming 12 mm thick ex pansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed by the Engineer-in-Charge.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and fair without using extra cement complete all as specified and as directed.
Supply only Integral waterproofing compound
Material and labour for Rendering 5mm thick in CM 1:3 as in ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
nium dividing strips, 1.5mm thick, inserted in position, conform to design complete all as specified and directed Engineer-In-Charge.
Material and Labour for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing all as specified and directed Engineer-In-Charge.
M & L for 15 mm thick rendering in CM 1:4 on brick work or concrete surfaces stone masonary surfacees finished even and smooth without usung extra cement.complete all as specified and as directed by Engr -in-Charge.
Material and Labour for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of surfaces and applying three coats of white wash on newly plastered surfaces of ceilings, complete as specified and as directed.
Material & labour for preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resitant primer complete all as specified and as directed by the Engineer-in-charge
Material & labour for preparing old plastered wall surfaces and applyingone coat of oil bound distemper over a coat of alkali resitant primer complete all as specified and as directed by the Engineer-in-charge
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over with and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, with and including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over with and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, with and including preparation of old plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed.
M&L for preparing of newly plastered surfaces of walls and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of primer Complete.
M&L for preparation of old surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Excavation over areas exceeding 1.5m in depth but not exceeding 3.00 m depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/loose soil, for foundation etc., or for shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified.
Supply and fix Mild steel bolts of dia exc 20 mm and n.ex 25 mm any type purpose made with hexagonal or square head one end and screwed the other, or screwed both ends;each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed by Engineer-in-charge.
Supply, install, testing and commissioning of HT 11KV switch board panel consisting of motorised automated VCB's (as incomer & as outgoing) totally enclosed, 630 Amps, 250 MVA, 11 KV fully interlocked draw out type breaker as per IEC 62271-100/200 sigle braek trip free breaker with motor operated spring charge mechanism mounted on truck carriage suitable for horizontal isolation, horizontal draw out type complete with self contained fully interlocked rack in rack out mechanism Breaker is featured with mechanical ON and OFF indicator with hand trip device, spring released coil, shut trip coil and auxiliary switch of 6 NO & 6 NC, Breaker should have braeking capacity of 25 KA for 3 sec. The busbar rating shall be 800 Amps for complete switch gear. The switch gear panel shall be of sheet steel construction with Aluminium Zink not less than 2.5mm thickness for load bearing section and not less than 2mm thickness for none load bearing and shall totally dust & vermin proof, Indoor type, free standing floor mounting type, compartment based with copper busbars, self supported insulated Busbar with full voltage rated should be used. VCB panel shall be confirming to IS 13947 with latest amendment and IP 42 class of protection comprising of necessary busbar extension and connection circuit breaker shall be completely encapsulated in epoxy housing. The manufacture of circuit breaker monitoring along with HMI as per specifications. The switch gear and control gera panel shall be of the fully are proof for 25 KA for 1 Sec, 110 volt DC Battery Bank (55 Nos x 2 volt) along with Battery charger to be Incomer-01 No Provide & connected to 11 KV HT panel with suitable control cable.
M&L for preparation of old surfaces of woodensurfaces of any description, not otherwise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F ABS body Health faucet, CP with 1.25m long flexible type 15 mm bore steel tube and wall hook, complete all as specified. Make: Jaquar Model No. ALD-573 or its equivalent as specified here in after.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer-in-charge.
S&F 110mm dia PVC (SWR) EWC connector bent type and jointed with solvent cement.complete all as specified and as directed.
Supply and fixing in repairs Towel rail 20mm dia, 600mm long, D type, stainless steel, chromium plated, completed all as specified. Make: Model No T6001A of Parryware or its equivalent as specified here in after.
Supply and fixing in repairs PVC connection (high density) 15mm bore 450mm with PTMT nuts both ends with rubber washer complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs chromium plated 15mm bore stop valves, fancy type, quarter turn, cast copper alloy, with long shank and cup (concealed), screwed down high pressure quarte
r turn screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer in charge.
Supply and fix in repairs 15mm bore chromium plated pillar taps, fancy type, cast copper alloy, quarter turn, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by Engineer in charge.
M&L for water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terrace etc., consisting of following sequences of operations on RCC surfaces; (a) Top of roof/terrace slab shall be applied 10mm thick plaster with cement mortar (1:3). (b) Roof shall be cleaned thoroughly by using wire brush [Mechanical / hand brush] to make it free from any loose particle, dirt / dust, etc. (c) After cleaned roof surface, the surface shall be painted with one coat of cold applied bituminous primer @ 0. 50 Lit per sq. m. (d) Atactic polypropylene polymeric modified prefabricated water proofing membrane five layered reinforced with non woven polyester matt of minimum 3mm thick weight not less than 3 Kg/Sqm shall be laid using butane torch application over entire roof surface and on vertical surface up to grooves as applicable with over laps of 100mm in both the directions. The overlaps shall be sealed by flames or as per manufacturer instructions. Water proofing membrane shall be tucked in wall to a depth of 25mm [minimum]. Groove made in wall shall be filled with bitumen mastic filling without any extra cost to Govt. (e) Ponding complete all as specified and as directed by Engineer-In -Charge. (f) Finally roof shall be finished with a coat of bituminous aluminium paint @ 0.20 Kg/Sqm in two coats. Note:- Quoted rate is deemed to include the cost of all sequences mentioned above including preparation of surfaces.
Supply and fix in repairs 15mm dia bore bib taps, fancy type, cast copper alloy, quarter turn, screwed down screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F 40mm dia HDPE pipes fixed to walls or laid in floors as waste pipe including all fittings, complete all as specified and as directed.
Supply and fix PVC(SWR) floor/Nahani trap 75mm size plain with grating including jointing to waste pipe complete with solvent cement all as specified and as directed by the Engineer-in-charge.
S&F for 75mm dia PVC (SWR) soil, waste and vent pipes single socket in any length with rubber ring joints , laid in trenches or in floors.
S&F for 110 mm dia PVC (SWR) soil, waste and vent pipes single socket in any length with rubber ring joints , laid in trenches or in floors.
S&F for 75mm dia PVC (SWR) soil, waste and vent pipes single socket in any length with rubber ring joints laid in fixed to wall.
S&F for 110 mm dia PVC (SWR) soil, waste and vent pipes single socket in any length with rubber ring joints , laid in trenches fixed to wall.
S&F for PVC(SWR) bend of 75 mm dia and of any radius.
S&F for PVC(SWR) bend of 110 mm dia and of any radius.
S&F for 75mm dia PVC(SWR) branch pieces,(single Y), equal or unequal ordinary or inverted with oval acces door.
S&F for 110mm dia PVC(SWR) branch pieces,(single Y), equal or unequal ordinary or inverted with oval acces door.
S&F PVC (SWR) vent cowl suitable for 75 mm bore pipes including jointing with solvent cement, complete all as specified.
S&F PVC (SWR) vent cowl suitable for 110mm bore pipes including jointing with solvent cement, complete all as specified.
S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), three layered, 1000 Litres capacity, hoisted and fixed in position all as specified in SSR Part I, with and including 20mm dia PTMT ball valve, complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) gully trap 125/110mm size including jointing to waste pipe with solvent cement, complete all as specified and as directed.
Supply and application of epoxy resin based anti-static levelling floor topping, consisting of araldite barriers kole primer with 100 microns thickness over and above self level primer 1 mm using GY257+Aradvr140+Quartz filter, self adhesive copper tape of size 25 mm width and 150 mm length at one end of the floor connected to copper earth strip,over and above the primer application of preformulated conductive base coat applied as conductive under coat at 100 microns thick having surface resistance of 3x103 ohms to 9x103 ohms. Top coat 2 mm thick using araldite GY257+Aradvr 2963 silica floor + Quartz sand + conductive pigment + preformulated conductive additives, the top coat system having surfece resistance of less than 50 K ohms, spread slowly and evenly levelling with serrated trowel including rolling slowly with spike rollers to clean the concrete floor before laying anti static flooring, complete all as specified and directed by the Engineer-in-charge.
M&L for 15mm thick Rendering on fair faces of brick work or concrete surfaces in two layers as 10mm thick in cement mortar 1:6 followed by 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instructions and finish the surface even and smooth without using extra cement, complete all as specified and as directed. Note: Supply of WPC will be measured and paid separately.
S&F Suspended false ceiling of gypsum board of 12 mm thick confirmiung to IS with GI promer chanel of size 20x30x27x0.9mm along perimetre of ceiling ,screwed fixed to wall help of nylon sleeves and screwes of 610mm centre to center supending GI in with on anodised aluminium snap grid frame work suspended with hangersc Board fixed with screw complete all as specified and directed by Engineer in charge.
Supply and fixing Trapezoidal profiled galvalume sheeting in lengths upto 12m to suit the site requirements.The profiled sheets shall be made out of 0.50mm base metal thickness, Cold Rolled steel of 550 Mpa yield strength conforming to IS 513 (1994) with hot dip metallic coating at minimum 150 gm/Sq.m. zinc- aluminium alloy coating mass (55% Aluminium, 43.5% zinc and 1.5% silicon) total of both sides. The colour shall have a total coating thickness of 35 micron of silicon modified super durable polyester paint system of approved colour, comprising of 20 microns exterior coat on top surface and 5 microns reverse coat on back surface over 5 microns primer coat on both surfaces.Roofing/wall cladding sheets shall be factory cut and supplied in required lengths (of upto 12 m) to suit shop drawings. The roofing/wall cladding sheets shall be crest fixed with 12- 14X55mm SDST screws ITW/ Corroshield make IS 1022 base material with TEK3/TEK4 point having flange thickness of minimum 2mm with special cyclonic washers all as per manufacturer's instructions. Roofing/wall cladding sheets shall be crest fixed with minimum 5 Nos. of above specified screws per metre sheet width at all the purlins/runners. Colour of sheeting shall be grey or apprroved by GE.
Demolition of cement concrete [unreinforced] in ground floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete [unreinforced] of any description in any position, not otherwise saperately provided for, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof/wall coverings complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding including removal serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
Demolition and breaking up to 150mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. for excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Dismantling water tanks of 1000 ltr capacity any type complete all as specified and directed by Engineer-in-charge.
Removing building materials etc. (other than spoil payable under Earthwork) to a distance of 15km , beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed and approved by GVMC
Supply and laying in repairs vitreous china Wash down water closet pan EWC (Pedestal pattern), white with 'P'or 'S' trap étc, including plastic water closet seat , closed pattern with flat bottom cover, mild steel chromium plated or aluminised hinging device, fixing bolts, etc including PVC valve less, syphonic action type low level flushing cistern 10 litres capacity, white with inlet ball valve, float and handle soft touch type including brackets, PVC flush pipe etc fixed with CP brass screws, complete all as specified and as directed. Make: JAQUAR Model No SLS-WHT 0318 or its equivalent as specified here in after.
Dismantling structural steel work including doors, stanchins, ladder, gates, rolling shutter, etc but excluding framed truss complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of wall and ceiling board or insulation boards of any thickness including cover filters etc complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5Sq.m. with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Material and labour for Rolled sections MS Square/rectangle as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying in trenches or ducts or passing through the pipe, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric LT power cable earth system (heavy duty) with stranded aluminium conductor 1100 volts grade of size 4 core 16 Sqmm complete all as specified and as directed by Engr-in-Charge
SUB TOTAL OF SCHEDULE "A" PART - IV
Supply and install hi wall split units indoor/outdoor complete inverter type with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR all as directed by Engr-in-Charge
SCHEDULE 'A' PART-IV (Cooling Appliances))
M & L for 10 mm thick rendering in CM 1:4 on brick work or concrete surfaces stone masonary surfacees finished even and smooth without usung extra cement.complete all as specified and as directed by Engr -in-Charge.
M&L for preparing of newly plastered wall surfaces and applying three coats of white washing all as specified and directed by Engineer in charge.
SUB TOTAL OF SCHEDULE "A" PART - I
Taking down old U/S light fitting HPMV of 80/125 /150W with control gear box all as specified and directed.
Taking down old u/s flameproof Switch and socket all sizes as directed.
Taking down old u/s Tube Light light fitting of sizes all as specified and directed.
M & L for point wiring on wall and surface/concealed on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for but for One light,ceiling,Wall,Ex.fan point controlled by one switch.
M & L for point wiring on wall and surface/concealed on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge but for One light point controlled by two way switches complete
M & L for point wiring on wall and surface/concealed on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge but for One 3 Pin socket outlet 15 amps socket on independent board but with cables of size 4 sq.mm,testing etc.as reqd
M & L for point wiring on wall and surface/concealed on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge but for One 3 pin socket outlet 5 amps on the same board with other switches,with cables 1.5sqmm size
M & L for point wiring on wall and surface/concealed on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge but for One 3 Pin socket outlet 5 amps socket on independent board but with cables of size 1.5sq.mm
S & F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
Supply & Fix piano Switch, flush type single pole, one way 5/6 Amp complete all as specified and directed.
Supply & Fix piano Switch, flush type single pole, Two way 5/6 Amp complete all as specified and directed.
Supply & Fix Switch, flush type single pole, One way 15/16 Amp complete all as specified and directed.
Supply & Fix Socket outlet 2 in 1, 3 pin, 5 and 15/16 amp flush type complete all as specified and directed.
Supply & Fix Socket outlet 3 pin, 5 amp flush type complete all as specified and directed.
S & F stepped type 5 step electronic fan regulator flush type on the existing phenolic laminated sheet etc, complete all as specified and directed.
Material and labour for Flame proof point wiring with 2.5 Sq mm (nominal a
rea) PVC insulated unsheathed FRLS cable with copper conductor, single core multi stranded 1100 V graded confirming to IS 694 : 1977 drawn in completed /surface stove enamelled steel conduit of size 20 mm dia with all accessories like asc solid Elbows, saddles etc including 20 mm metalic flexible pipe at the connecting point where necessary and 2.5 Sqmm one single core PVC unsheathed FRLS cable with multi stranded copper conductor as earth condinuity conductor and connected to common earth dolly complete all as specified and directed by Engr-in-Charge. but for One light,ceiling,Wall,Ex.fan point controlled by one switch.
M&L for Reinforced Ready Mixed Cement Concrete M–40 Design Mix with admixture Auramix 400 of Fosroc o
r Smartcare maximo plast PX range of Asian Paints or its equivalent as specified here in after, as in Foundations including Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns etc., complete all as specified and as directed.
M&L for Reinforced Ready Mixed Cement Concrete M–40 Design Mix with admixture Auramix 400 of Fosroc or Smartcare maximo plast PX range of Asian Paints or its equivalent as specified here in after, as in beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs and the like, complete all as specified and as directed.
Material and labour for Flame proof point wiring with 4.0 Sq mm (nominal area) PVC insulated unsheathed FRLS cable with copper conductor, single core multi stranded 1100 V graded confirming to IS 694 : 1977 drawn in concealed/surface stove enamelled steel conduit of size 25 mm dia with all accessories like asc solid Elbows, saddles etc including 25 mm metalic flexible pipe at the connecting point where necessary and 4.0 Sqmm one single core PVC unsheathed FRLS cable with multi stranded copper conductor as earth condinuity conductor and connected to common earth dolly complete all as specified and directed by Engr-in-Charge.
M&L for circuit/ sub main wiring with two runs of 2.5Sq.mm. surface type nominal cross section area FRLSH PVC insulated unsheathed cable with copper conductor, single core multi stranded 1100 V along with one run of 2.5Sq.mm. for earth FRLS PVC insulated unsheathed cable with copper conductor, single core multi stranded through and drawn through and including rigid PVC conduit of suitable dia and accessories including taking down old unserviceable wirirng complete all as specified and as directed by the Engineer-in-Charge. Note :- Two runs of cable for phase,neutral and one run of earth wire along with PVC conduit shall be measured as one unit.
SUB TOTAL OF SCHEDULE "A" PART - III
SUB TOTAL OF SCHEDULE "A" PART - III
Supply & Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 230V complete all as specified and as directed by Engr-in-Charge
Removal of excavated material [Soil] to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified.
Taking down carefully existing copper/aluminium point wiring with and including all fittings such as light fittings, socket, switches, ceiling roses, pendants, regulators, conduit etc., and making good disturbed surfaces of walls, floors to match with existing surface, complete all as specified.
Taking down carefully existing unserviceable MCB DB TPN/SPN., and including all fittings and making good disturbed surfaces of walls, floors to match with existing surface, complete all as specified.
Supply and fix Flame proof - weather proof switch socket & plug combined 16 A,230 V(2P+Earth) complete all as specified and as directed by Engr-in-Charge
Supply and fixing flame proof LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all prewired and including connecting up with threeaccessories core flexible copper conductor cable with suitable size all as specified and directed by Engr-in-Charge..
Supply and fixing LED Highbay light fitting 1x70 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core complete all as specified and directed by Engr-in-Charge..
Supply and fixing of flame proof Wall Mounted fan AC single phase 230/240 V of size 600mm sweep with louver all as specified and directed by Engr-in-Charge.
Supply and fix Flame proof - weather proof high bay LED fitting suitable for 80 Watt 230V all as specified and directed by Engr-in-Charge.
Supply and fix Flame proof - weather proof high bay LED fitting suitable for 150Watt 230V all as specified and directed by Engr-in-Charge.
Supply and fixing of 415V 50 Hz 4P MCCB of 125A, 25 KA all as specified and directed by Engr-in-Charge.
Supply and fixing of 415V 50 Hz MCB 4P of 63A,25 KA Capacity all as specified and directed by Engr-in-Charge.
S&F in repair testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs. all as specified and directed by Engr-in-Charge.
S&F in repair testing and commissioning of MCB SPN 240 volt 40 amp 10 KA capacity having C-curve characteristics connected with suitable lugs all as specified and directed by Engr-in-Charge.
M & L for single pole and neutral enclosure with a two pin and earth plug and Socket complete with one single pole MCB 20Amps, 240V all as specified and directed by Engr-in-Charge.
Supply and fix in MCB DB single door type SPN 2 ways 240V all as specified and directed by Engr-in-Charge.
Supply and fix MCB DB double door type SPN 4 ways 240V all as specified and directed by Engr-in-Charge.
Supply and fix MCB DB double door type SPN 8 ways 240V all as specified and directed by Engr-in-Charge.
Supply and fix MCB DB double door type SPN 12 ways 240V all as specified and directed by Engr-in-Charge.
M&L for circuit/ sub main wiring with two runs of 4.0Sq.mm. nominal cross section area FRLSH PVC insulated unsheathed cable with copper conductor, single core multi stranded 1100 V along with one run of 4.0Sq.mm. FRLS PVC insulated unsheathed cable with copper conductor, single core multi stranded through and drawn through and including rigid PVC conduit of suitable dia and accessories including taking down old unserviceable wirirng complete all as specified and as directed by the Engineer-in-Charge. Note :- Two runs of cable for phase,neutral and one run of earth wire along with PVC conduit shall be measured as one unit.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer-in-charge.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in crimping as specified complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs Vitreous china wash hand basin size 630 x 450mm flat back, white including brackets, cutting for and pinning in ends of brackets, 40mm dia CP brass waste fittings, complete all as specified. Make: JAQUAR Model no FNS-WHT 0606 or its equivalent all as specified here in after.
Supply and fix MCB DB double door type TPN 4 ways 415V all as specified and directed by Engr-in-Charge.
Supply and fix MCB DB double door type TPN 6 ways 415V all as specified and directed by Engr-in-Charge.
Supply and fix MCB DB double door type TPN 8 ways 415V all as specified and directed by Engr-in-Charge.
Supply and laying in trenches or ducts or passing through the pipe, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric LT power cable earth system (heavy duty) with stranded aluminium conductor 1100 volts grade of size 4 core 25 Sqmm complete all as specified and as directed by Engr-in-Charge
Per Point
Material and labour for vitrified Ceremic tiles 10mm thick (square/ rectangular) polished, area of each tiles exc. 0.36 SQM, but not exc 0.42 SQ.M in floors etc. set and jointed in neat cement slurry dmixture of pigment to match Light Shade laid over and including 15mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement with admixture of pigment to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,on vertical surfaces. set and jointed in neat cement slurry and pointed in white cement with admixture of pigment to match the shade of tiles laid over and including 10mm thick backing coat in CM 1:4, set all as specified and directed by Engineer in charge.
SCHEDULE "A" PART - II [INTERNAL ELECTRIFICATION]
SUB TOTAL OF SCHEDULE "A" PART - II
SCHEDULE 'A' PART-III (External Electrification)
Supply and spreading river sand in trenches as cushioning to under ground cable on top and bottom of cable and levelling & ramming complete all as specified and directed by Engineer-in-charge. Note:- Punned thickness of 18cm will be measured.
M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed Engineer-In-Charge.
Supply, laying, testing & commissioning in cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm , 3.5 Core all as specified and directed by Engr-in-Charge. Note: Earth work will be measured and paid separately.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with and including HDPE pipe of 80mm dia suitable for 6 KGF/Sq.cm working pressure, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of using galvanised iron strip 25×4mm as earthing lead all as shown in electrical plate No.3 of SSR Part-I including excavation/earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 25mm bore GI pipe medium grade for GI strip protection and galvanised iron strip 25×4mm including testing complete all as specified and directed by Engineer-in-Charge. Note : Earth strip will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
M&L for fabrication of LT Cubicle indoor type, factorymade, compartment type,type tested panel with CRCA sheet of 2 mm thick as per relevent IS, suitable for 3 phase, 4 wire system, including provision of 2 Nos spare compartments (for future planing work), suitable capacity Almunium busbar, having 1.5 times bearing capcity of main incoming switch gear ,digital metering eqpt etc complete all as specified with following:- Incoming :- (a) 1250A ACB 50 KA manual drawout type Suitable for 415V -01 Nos. Outgoing:- (a) 700A MCCB 50 KA Adjustable thermal and fixed magnatic type for 415V -01 Nos. (b) 200A MCCB 35 KA Adjustable thermal and fixed magnatic type -01 No. (c) 100A MCCB 25 KA Adjustable thermal and fixed magnatic type -02 No. (d) Digital Ammeter & Voltmeter for incomming & outgoing. (e) LED indication lamp for RYB for in-coming indication. (g) LED indication lamps for breaker ON/OFF indications. (h) Multi functional meter
Supply and laying in repairs Galvanised steel water tubing 15mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid in floors and including testing, complete all as specified and as directed.
Supply and laying in repairs Galvanised steel water tubing 20mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid in floors and including testing, complete all as specified and as directed.
re 300 sq mm all as specified and directed by Engr-in-Charge. Note: Earth work will be measured and paid separately.
Dismantling and taking down old panel board of incoming capacities 500A/ 630A/ 1250A from existing location after disconnecting all electrical connections at various locations of test bed facilities at building No - 29 and deposit it to store yard of GE (I) DM all as directed by Engr in Charge.
Supply, laying, testing & commissioning in cable XLPE insulated, screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 co
Supply and fixing in repairs Vitreous china white half stall type urinal with grating and unions for discharge pipe line including 32 mm dia PVC polythene pipe of suitable length from the urinal to trap of below including necessary jointing, complete all as specified. Make: JAQUAR Model no URS-WHT 0701 or its equivalent all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. Note: Quoted rate shall be inclusive of Cutting / separating of reinforcement as required.
M&L in repairs for Reinforcement using TMT CRS bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. Note : quoted shall be deemed to include for removal of existing corroded reinforcement and providing new CRS reinforcement by welding to the column, beam and sun shades etc
Supply and fixing LED lights fitting 1x 40W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. Make : Cat No DURABS40WLED830SPCSS of Havells or in equivilant make.
Supply and fixing LED security lights fitting 36W, 220V, AC with driver, connecting up with three core flexible copper conductor cable of suitable size including bracket complete all as specified and directed by Engr-in-Charge. Make: Cat No GL9C0801436CD of Goldmedal or in equivilant make.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.all as specified and directed by Engr-in-Charge. Make: Cat No PLANO2X2PLR36WLED830TAPS of Havells or in equivilant make
Supply and fixing LED highbay light fitting 1x80 Watt 230V CMRI certified recommended and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core complete all as specified and directed by Engr-in-Charge. Make: Cat No GAZELLAHBP80WLED857PBOPC of Havells or in equivilant make
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I including excavation/earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 25mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire including testing complete all as specified and directed by Engineer-in-Charge. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
Taking down old existing U/G HT cables of any size all as directed by Engr- in- Charge.
Taking down old existing U/G LT UG cables of any size all as directed by Engr- in- Charge.
Taking down carefully existing unserviceable MCB SP, SPN and making good disturbed surfaces of walls, floors to match with existing surface, complete all as specified.
Supply, installation, testing and commissioning of 1600 KVA 11 KV/380V-433V, ONAN 3 phase 50Hz, Indoor Type, copper wound with OLTC (ON load tap changer) step down dual type transformer (800KVA with 380V and another 800KVA with 433V) complete as per IS 2026 with all modern fittings including all standard fittings and acessories, complete all as specified and as directed by the Engineer-in-Charge. The specifications were as under:- (i) The transformer shall be installed in hot, humid tropical atmosphere. All equipment accessories and wiring shall be provided with tropical finish to prevent fungus growth. (ii) The transformer shall be OLTC Type & capable of continuous operation of rated output under the operating conditions of voltage and frequency variations as per statutory limits governed by relevant Indian Standard and Indian Electricity Rules, 1956 / IEC with latest amendments in force. (iii) Requirement: 11KV/380V-433V OLTC Type with ON LOAD Tap Changer (OLTC), Tapping range +5% to - 5% in 04 steps of 2.5 % (LV side). (iv) Voltage Ratio: No load voltage 11000/380-433 volts
within tolerance as stipulated in latest IS standard. (v) Insulating material shall be of proven design. Class A Insulation (vi) Rating: The transformer shall have a continuous rating as specified at any of the specified tapping position and with the maximum temperature rise specified.
M&L for fabrication of LT Cubicle indoor type, factorymade, compartment type,type tested panel with CRCA sheet of 2 mm thick as per relevent IS, suitable for 3 phase, 4 wire system, including provision of 2 Nos spare compartments (for future planing work), suitable capacity Almunium busbar, having 1.5 times bearing capcity of main incoming switch gear ,digital metering eqpt etc complete all as specified with following:- Incoming :- (a) 800A ACB 50 KA manual drawout type Suitable for 415V -01 Nos. Outgoing:- (a) 250A MCCB 35 KA Adjustable thermal and fixed magnatic type -01 No. (b) 200A MCCB 35 KA Adjustable thermal and fixed magnatic type -01 No. (c) 125A MCCB 25 KA Adjustable thermal and fixed magnatic type -01 No. (d) 100A MCCB 25 KA Adjustable thermal and fixed magnatic type -02 No. (e) 80A MCCB 25 KA Adjustable thermal and fixed magnatic type -03 No. (f) 63A MCCB 25 KA Adjustable thermal and fixed magnatic type -03 No. (g) Digital Ammeter & Voltmeter for incomming & outgoing. (h) LED indication lamp for RYB for in-coming indication. (i) LED indication lamps for breaker ON/OFF indications.(j) Multi functional meter
Supply and laying reinforced precast concrete cable cover, class HV, Type 1 with flat size 300mmx180mmx40mm all as specified and directed by Engr-in-Charge.
S&F Ceiling fan complete with blades, down rod as per site requirement to maintain 2.25m height from FFL and minimum 30cm clearance from ceiling roof, including electronic regulator step type and accessories, 230Volt, 1400 mm sweep, minimum air delivery 210 CFM with service value 6.0BEE, with brushless direct current motor , BEE 5 star rated BLDC complete all as specified and as directed.
M&L for circuit/ sub main wiring with two runs of 6.0Sq.mm. nominal cross section area FRLSH PVC insulated unsheathed cable with copper conductor, single core multi stranded 1100 V along with one run of 6.0Sq.mm. FRLS PVC insulated unsheathed cable with copper conductor, single core multi stranded through and drawn through and including rigid PVC conduit of suitable dia and accessories, including taking down old unserviceable wiringcomplete all as specified and as directed by the Engineer-in-Charge. Note :- Two runs of cable for phase,neutral and one run of earth wire along with PVC conduit shall be measured as one unit..
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 300 sqmm all as specified and directed by Engr-in-Charge.
Supply and lay electrical insulating rubber mat of 1 meter x 2 meter x 2.5 mm all as specified and directed by Engr-in-Charge.
Dismantling and taking down old VCB (04 Nos) from existing location after disconnecting all electrical connections at various locations of test bed facilities at building No - 29 and deposit it to store yard of GE (I) DM all as directed by Engr in Charge.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size all as specified and directed by Engr-in-Charge..
Supply, laying, testing & commissioning in cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. mm,3.5 Core all as specified and directed by Engr-in-Charge. Note: Earth work will be measured and paid separately.
stage.html
html • 0.07 MB
techsummary_830512.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.17 MB
3467TestBedStructDrgs.pdf
Tender Documents • 4.93 MB
3467TestBedTender.pdf
Tender Documents • 0.87 MB
3467TestBedIP.pdf
Tender Documents • 2.44 MB
3467TestBedArchDrgs.pdf
Tender Documents • 1.21 MB
BOQ_830512.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .