Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 CrAdmitted-Finance MAHESHMATI PO DIST MALDA PIN 732101 WEST BENGAL | MALDA | MALDA | WEST BENGAL | 732101 | ₹1.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Statutory document as per NIT not submitted within stipulated date and time |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Qualified |
| Sl No | Description | Qty | Unit | M/S GOURANGA PRABHU SARKAR L2 | M/S JOYDEV JANA L3 | MAA BISHALAXMI ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Construction of 01 No. (G+2) 4 unit C type Building with provision of extension up to (G+3) and its allied work at Chiranjibpur Colony Complex under Haldia Area Office | 1 | Nos | 1,33,94,300.54 ₹1,33,94,300.54 | 1,36,25,446.57 ₹1,36,25,446.57 | 1,33,59,020.87 ₹1,33,59,020.87 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
25 Mar 2026, 3:00 pmClosed
The Chief Engineer (OandM)- II
Chief Engineer (OandM)- II, WEST BENGAL STATEELECTRICITY TRANSMISSIONCOMPANY LIMITED, Vidyut Bhaban, 10th Floor (D Block), Salt Lake City, Kolkata 700091
Construction of 01 No. (Gplus2) 4 unit C type Building with provision of extension up to (Gplus3) and its allied work at Chiranjibpur Colony Complex under Haldia Area Office
2026_SETCL_1014740_1
CE/(OandM)-II/HALDIA /CIVIL/ 2025-26/38, DATED 27.02.2026
Open Tender
CIVIL WORKS
Percentage
546 days
WBSETCL, Vidyut Bhavan, Salt Lake, Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.2 L
WBSETCL,Vidyut Bhavan, Salt Lake, Kolkata- 700091
25 Jun 2026
27 Feb 2026
30 Mar 2026
27 Feb 2026
25 Mar 2026
16 Mar 2026
27 Feb 2026 - 6 Mar 2026
11 Mar 2026
Construction of 01 No. (G+2) 4 unit C type Building with provision of extension up to (G+3) and its allied work at Chiranjibpur Colony Complex under Haldia Area Office
Percentage BoQ
BoQ_Ver3.0
NIT No.:- CE/(O&M)–II/HALDIA /CIVIL/ 2025-26/38, DATED 27.02.2026
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spills within a lead of 75m as directed. The items include necessary trimming the sides or trenches, leveling, dressing and ramming the bottom, bailing out water as required complete.
a) Depth of excavation not exceeding 1.50m
b) Depth of excavation for additional depth beyond 1.5 m and upto 3m but not requiring shoring.
Filling in foundation or plinth by silver sand in layers not exceeding 150mm, as directed and consolidating same by through saturation with water ramming complete, including the cost of supply of sand.
Pre-constructional anti-termite measures: Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration ) with water by weight at the rate of 5 litres per sq,m of the surface before sand bed or sub grade is laid . Holes upto 50 mm to 75 mm deep at 150 mm centre to centre both ways shall be made with 12 mm , diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion . The work shall be carried out as per specification described in para 6.4 of code IS-6313 (Part -II) 1981
Dismantlling all types of masonry excepting cement concrete plain or reinforced,stacking serviceable materials at site & removing rubbish as directed within a lead of 75 M .
In ground floor including roof
Dismantling all types of plain cement concrete work , stacking servicible material at site and removing rubbish as directed within a lead of 75 mm including stacking of steel bars.In ground floor including roof.
a) Upto 150 mm thick
Dismantling R.C. floor, roof, beams etc. including cutting rods & removing rubbish as directed within a lead of 75m including stacking of steel bars.
In ground floor including roof
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
125 mm thick Flyash Brick work as per IS-12894-2002 in cement mortar (1:4) (i) In Gr floor.
250 mm. thick Brick work with Fly Ash Bricks (250mmx125mmx75mm) as per IS 12894:2002 in cement sand mortar (1:4)
a) In foundation and plinth
b) In superstructure; Ground Floor
250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm - Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS:3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge .
i) In Super Structure, Ground Floor.
ii) In 1st floor
iii) In 2nd floor
iv) In 2nd floor
125 mm thick Autoclave aerated concrete block Work with size 625 mm x 250mm x 125 mm- Grade-I,having drying Shrinkage less than 0.05% conforming to IS: 2185 ( Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981,with permissible loss on ignition upto 6%), lime , cement and complete in all respect as per direction & satisfaction of Engineer -in Charge. a) laid in Cement Mortar (1:6)
i) In Super Structure, Ground Floor
ii) In 1st floor
iii) In 2nd floor
iv) In 3rd floor
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in Ground floor. as per relevant IS codes. a) Pakur variety
(i) In Gr floor
Ordinary Cement Concrete (mix 1:11/2:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, as per relevant IS codes. a) Pakur variety
(i) In Ground floor
(ii) In 1st floor
(iii) In 2nd floor
(iv) In 3rd floor
Cement concrete with graded stone ballast (40mm size excluding shuttering) Pakur Variety
A) In Ground floor, a) 1:3:6 proportion,
Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm.dia rod complete including mending damages. Payment for damage and repair to be made separately.
R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. (a) 37.5 mm. Thick panels SAIL/ TATA/RINL
(i) In 1st floor
(ii) In 2nd floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.(i) In Ground floor
(b) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (i) In ground floor
(ii) In 1st floor
(iii) In 2nd floor
(iv) In 3rd floor
(c) 25 mm to 30 mm shuttering without staging in foundation) i) In ground floor
Hire and Labour Charges for shuttering with hard wood for precast R.C. Slab curved, or stright and striking out the same including fitting, fixing the precast slab in position with necessary carriage and haulage, hosting etc,complete in all respect.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups binders etc. including supply of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
a) For works in foundation, basement and upto roof of ground floor/upto 4M
Tor steel / Mild steel (SAIL/TATA/RINL)
(i) In Gr. floor
(ii) In 1st floor
(iii) In 2nd floor
(iv) In 3rd floor
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2nd coat just before brick masonry work) as directed
Supplying and laying polythene sheet (150 gm/ sq.m) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @1.75 kg/sq.m all complete including all materials and labour.
In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (i) 35 mm. thick
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge. (a) Slab Thickness 20 to 25 mm
(i) In 1st floor
(ii) In 2nd floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone
Extra cost of labour for grinding Kota Stone Floor in treads and riser of steps
Supplying & laying true to line and level vitrified tiles of approved make ( size not less than 600 mm x 600 mm x10 mm th ) in floor skirting etc set in 20 mm sand cement mortar (1:4) and 2 mm th cement slurry back side of tiles using cement 22.91 kg / m2 or using polymerised adhesiv (6 mm th layer applied directly over finished artificial stone floor/mosaic etc without any backing course ) laid after application slurry using 1.75 kg of cement per sq m below mortar only, joints grouted with admixture of white cement and colourng pigment to match with colour of tiles / epoxy grout material of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of material , labour and all other incidental charges complete true to the manufacturers specification and direction of E.I.C. (With cement , synthetic adhesive and grout material to be supplied by the contractor.)
With application slurry 1.75 kg / sq m ,20 mm sand cement mortar (1:4) & 2 mm th cement slurry at back side of tiles , 0.2 kg / sqm white cement for joint filling and pigment.
Light colour
i) In 1st floor
ii) In 2nd floor
Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening ofconcrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge.
i) In 1st floor
ii) In 2nd floor
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials.[Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling [Red variety ]
(i) 25mm thick
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material.[Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5.
Supplying and laying in the specified pattern of Interlocking concrete Block Pavements (ICBP) with concrete blocks (with Concrete grade as specified as per Table 1 of IS 15658:2006) manufactured from BIS licensee manufacturere,with spacer nid (small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks,as per CL No. 3.26 of IS:15658) and of specified size and shape with aspect ration(The ratio of length to thickness of a paver block ,as per CL. No. 3.3 of IS:15658) as per Table 2 of IS :15658 with flxural strngth/breaking load as per Annexure G of IS:15658,on the prepared base course of sppecified CBR as per Table 1 of IRC SP63(2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35mm thick (grading of the bedding sand as per clause 6.51 of IRC SP-63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP-63) and completing the edges with cut block as per CL. No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand,compaction,levelling and filling up the edge gap. Grey, 50 mm thick
Supply and laying true to line and level 20 mm / 25 mm th. Precast roof tiles made of cement concrete with stone chips as per approved strength and density set in 25 mm avg th. Cement mortar (1:3) and filling up joints (3 mm wide ) with cement sand mortar (1:1) applying cement slurry @ 1.75 kg per sqm back of tiles and then setting close the precast tiles , finishing up the joints with slurry already laid and finally finishing the top surface including providing 150 mm high skirting with the same tiles flushed with the inside surface of parapet wall , finishing the mouth of rain water pipe , curving etc. as necessary complete as per direction of the E.I.C
a) For 25 mm th. Precast tiles (cement 14.6 kg /Sqm underlayer)
(i) In 2nd floor
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm) (To be used for repair works only)
M.S. or Ornamental grill of approved design joints continuously welded with M.S W.I flats and bars of windows railing etc fitted and fixed with necessary screws and lugs in gr floor.
Grill weighing above 10 kg/ sq m & upto 16 kg /sq. m
i) In 1st floor
ii) In 2nd floor
iii) In 3rd floor
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials
Collapsible gate with 40 mm x40 mm x 6 mm Tee as top and bottom guide rail ,20 mm x 10 mm x2 mm vertical channels 100 mm apart in fully stretched position 20 mm x5 mm M.S. flat as collapsible bracing properly rivetted and washered including 38 mm steel rollers including locking arrangement , fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes chasing etc. in walls floor etc. and making good damages complete. i) In Ground floor
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm including watering & ramming etc. layer by layer complete.
(a) With earth obtained from excavation of foundation
Wood work in door & window frame fitted & fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete , Iron Butt hinges and M.S.Clamp.
a) Sal (Local)
i) In 1st floor
ii) In 2nd floor
Supplying fitting fixing in position of approved P.V.C. door frame (matt finish ) made of extruded P.V.C. multichamber hollow section having dimensions 60 mm x 50 mm x2 mm, horizontal section will be joined with vertical section by galvanuized steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges , one steel tube 40 mm x 20 mm x 1.20 mm will be inserted on one full vertical side of the frame ( hinge side ) as reinforcement , the frame will then be fixed in the opening with the help of P.V.C. expanable fastner wooden gutties and galvanised steel screws including cost of all materials and labours , hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete.
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings (a) 35 mm thick shutters (single leaf)
i) In 1st floor
ii) In 2nd floor
iii) In 3rd floor
PVC door shutter -37 mm thick Supplying fitting fixing P.V.C door shutter of approved quality & shade in position , the style and rail of the P.V.C. door shutter will be made of rigid P.V.C multicavity hollow chamber of suitable size and section with 2.0 mm wall thickness , the section will have 2 nos built in beads horizontal & vertical section shall be fixed to each other by self tapping screw and 2 nos of solid plastic or M.S. tubular galvanised bracket of length 200 mm x80 mm and other 100 mm x100 mm both 1.20 mm in each corner of shutter frame for placing hinges . Polymer based multicavity hollow section of 105 mm x37 mm with 2.0 mm wall thickness will be fitted in thje middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends & screws for both sides . The section frame will then be fitted in by prepanels of size 100 mm x20 mm with wall thickness 1.2 mm and 2 nos of 6 mm dia bright rods will be inserted horizontally with both side check and nut system and streches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to withstand wear and tear . The rate is inclusive of cost of all materials , labour , and hire of tools and plants and appliencies . Carrige of all materials taxes and all other incidental charges complete The rate is exclusive of cost of hinges , hasp bolt , tower bolt, door ring etc
i) In 1st floor
ii) In 2nd floor
Supplying fitting and fixing hinge cleat in position excluding the cost of hinge and other fittings.
a) With 75mm Iron Butt-Hinge
i) Local sal
Supplying fitting & fixing M.S. clamp for door & window frame made of flat bent bar , end bifurcated with necessary screws etc by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately)
(a) 40 mm x 6 mm, 125mm length
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Door stopper (Brass)
Anodised aluminium barrel/tower/socket bolt (full covered) of approved quality manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws.
i) 300 mm long x 12mm dia bolt
ii) 150mm long x 10mm dia bolt
Anodised aluminium Aldrop/sliding bolt of approved quality manufactured from extruded section conforming to I.S. specification (2681/66) fitted and fixed complete.
a) 300 mm x 16 mm dia bolt.
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S 205/66 ) fitted and fixed with cadmium plated screws.
i) 100 mm x 75 mm x 4mm
Anodised aluminium D type handle of approved quality manufactured from extruded section conforming to I.S specification( I.S 230/72) fitted & fixed complete. (a) With continuous plate base (Hexagonal/Round rod)
i) 125mm grip x 10mm dia rod
Metallic magic eye of approved quality fitted and fixed complete
125mm long wooden buffer block : Sal (Malayasian)
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] 16mm
i) In 1st Floor
ii) In 2nd Floor
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof.Glossy/Matt/Suede excluding surface texture or metallic lustre (i) Thickness of laminate 1 mm
i) In 1st floor
ii) In 2nd floor
Labour for chipping of concrete surface before taking up plastering work
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off of chamfering corners as directed and raking out joints or roughening of concrete surface including throating, nosing and drip course where necessary (In Ground Floor).
a) 20 mm thick plaster (1:6)
i) In Gr. floor
ii) In 1st floor
iii) In 2nd floor
iv) In 3rd floor
b) 15 mm thick plaster (1:6)
i) In Gr. floor
ii) In 1st floor
iii) In 2nd floor
iv) In 3rd floor
c) 10 mm thick plaster (1:4)
i) In Gr. floor
ii) In 1st floor
iii) In 2nd floor
iv) In 3rd floor
Neat cement punning about 1.5mm thick in wall dado, window, sills, floor, drain etc.
Applying Interior grade Acrylic primer of approved quality and brand on plastered surface or concrete surface old or new to receive Distemper/Acrylic emulsion paint including scraping and preparing the the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C
One coat
a) Water based Interior grade Acrylic primer.
i) In Gr. floor
ii) In 1st floor
iii) In 2nd floor
iv) In 3rd floor
Applying Exterior grade Acrylic primer of approved and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturers specification and as per direction of E.I.C (One Coat)
i) In Ground Floor
ii) In 1st Floor
iii) In 2nd floor
iv) In 3rd floor
Protective and decorative Acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per direction of E.I.C.to be applied over a coat of acrylic primer as required. The rate includes the cost of material,labour, scaffolding and all incidental charges but excluding the cost of primer. Manufacturer following are the approved manufacturer. Normal Acrylic emulsion. Berger/Asian/ICI/Nerolac/Dulux/Shalimar Two Coats
i) In Ground floor
ii) In 1st floor
iii) In 2nd floor
iv) In 3rd floor
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surface by sand papering etc.
Priming one coat on steel or other metal surfacewith synthetic oil bound primer of approved quality including smoothening surface by sand papering.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. With super gloss (hi gloss) Two coats (with any shade except white)
a) On timber or plastered surface
b) On steel or other metal surface
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty. Two coats. a) Standard quality.
Painting with ready mix black japan (Two coats )
Coal tarring a) Two coats
French polishing to wood work including preparing surface (ordinary gloss)
(a) On new work only
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thick)
Supplying fitting fixing C.I.grating heavy type
i) Above 100 mm and upto 150 mm square/round.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. 110mm Dia.
a) UPVC Pipes
b) UPVC Fittings : Shoe
Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised "C" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc
i) 65 mm. x 65 mm. x 8g
Supplying profiles of required section made of Aluminium Alloy extrusions confirming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour /natural) matt finished confirming to IS:1868-1983 for fabrication of composite door,sliding & casement windows, partition, formed of basic section of any ISI embossed/certified make and brand as per direction of Engineer-in-charge. (A) In 10-12 Micron thicness Annodizing film. Natural white
a) 2 track sliding window
i) Bottom frame
ii) Top & side frame
b) 3 track sliding window
i) Bottom frame
ii) Top & side frame
c) Shutter for all track sliding window
i) Bottom & Top member
ii) Style side member
iii) Interlocking member
Labour charge for fabrication and installation of composite door,window,partiotios made from annodized extuded alloy aluminium sections.
(A) Glazed aluminium windows made of extruded and annodized alloy aluminium sections, fabrications, including citting to proper shape and size, drilling and alignment of window shutter frame fitted within built locking arrangements, sliding rollers and other necessary fittings fixture, adhesives and joineries along with extuded neoperine or EPDM gasketing in between window frame and masonarywork (wall, column, beam, lintel etc.) as well as between glass and shutter frame for fixing the glass and poly shulphate sealent and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of E.I.C. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium section, glass, neoprene/ EPDM gasketing, locking arrangement and rollers
a) 2 track sliding window
i) In 1st floor
ii) In 2nd floor
iii) In 3rd floor
b) 3/4 track sliding window
i) In 1st floor
ii) In 2nd floor
iii) In 3rd floor
Supplying EPDM gusket of approved make and brand as per direction of Engineer in Charge.
i) For Sliding Windows
a) T shaped EPDM gasket for frames
b) U shaped EPDM gasket for frames
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987
i) 6 mm thick clear glass.
ii) 6 mm thick coloured/tinted/smoked glass
Supplying PVC rollers for sliding windows as per direction of E.I.C
Supplying maruti lock (100mm)
Supplying fitting and fixing brass ferrule including connection with G.I pipe of TATA make of following dia and upto 450 mm long with screw , jamnut , socket etc. complete in all respect , including cutting trenches in all sorts of soil and filling up the trenches as per direction of the EIC
i) 25mm dia
ii) 20mm dia
Supplying fitting and fixing shower of approved brand and make.
a) Chromium plated round shower with revolving joint (Equivalent to code no. 541 (N) & Model - Tropical / Sumthing special of ESSCO or similar brand
Supplying fitting and fixing gunmetal wheel valve of approved brand and make testedto 21 kg per sq cm
iii) 32 mm
Supplying fitting & fixing bib cock or stop cock
(a) Chromium plated bib cock short body (Equivalent to Code no. 511 & Model - Tropical / Sumthing special of ESSCO or similar brand
(b) Chromium plated stop cock (Equivalent to Code no. 513 (A) & 513 (B) & Model - Tropical / Sumthing special of ESSCO or similar brand
c) Chromium plated angular stop cock with wall flange (Equivalent to Code no. 5053 & Model - Florentine of jaquar or similar brand
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)
(a) For Exposed Work
iii) 25mm
(b) For Concealed Work
iii) 25mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross,elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted including cost of all materials ,jointing materials, cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories,specials.)
iii) 50mm
Supplying, fitting and fixing 10 litre P.V.C low down cistern confirming to I.S. specification with P.V.C. fittings complete. C.I. brackets including two coats of painting to brackets etc.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (black) - Multilayer
a) 1500 litre capacity
Labour for hoisting plastic water storage tank.
Above 1500 litre upto 5000 litre capacity.
i) Upto 1st story from G.L.
ii) From 1st story to 2nd story
iii) From 2nd story to 3rd story
Labour for punching hole in plastic water storage tank upto 50 mm dia
Supplying ,fitting &fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75mmx75mm wooden blocks, C.P. waste fittings of 32mm dia, one approved quality brass C.P. pillar cock of 15mm dia,C.P. chain with rubber plug of 30mm dia., approved quality PVC waste pipe with CP nut, 32mm dia., 900mm long approved quality PVC connection pipe with heavy brass CP nut including mending good all damages and painting the brackets with two coats of approved paint
a) 550mm x 400mm Size
Supplying fitting and fixing pedestral of approved make for wash basin (White)
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.
i) 630 mm X 550 mm X 180 mm
Supplying, fitting and fixing 15mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL/SUMTHING SPECIAL of ESSCO or similar brand)
Supplying,fitting and fixing approved brand 32mm dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps
1050 mm long
CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand)
Supplying, fitting & fixing Aluminium domical grating i) 100mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
A) Pipes
i) 110 mm Single Socketed 3m length.
ii) 75 mm Single Socketed 3m length.
B) Fittings
i) 110 mm Coupler
ii) 110mm Door tee
iii) 110mm Bend 87.5
iv) 110mm Vent Cowl
v) 110 X 110 P-Trap 75 mm
Supplying fitting fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.
With P trap 110 X 110 X 75 mm
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).
580 mm X 440 mm
Supplying fiting and fixing Closet seat of approved make with lead and C.P. hinges , rubber buffer and brass screws complete
Plastic (hollow type) White
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specification supported on fibre glass frame of any colour, frame size 550mm x 400mm
Supplying fiting and fixing glass shelf with aluminium guard rail A) Ordinary type with 5.5 mm sheet glass
i) 450 mm x 125 mm
Supplying fiting and fixing soap holder. A) PTMT (Prayag) or equivalent
Supplying fiting and fixing towel rail with two brackets. a) C.P. over brass
25 mm dia and 600 mm long
Constructing Inspection pit of inside measurement 600 mm x600 mm x upto 600 mm (depth) with 250 mm th 1 st class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm th cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling , 15 mm th cement plaster (1:4) to inside walls and outside walls upto G.L.and 20 mm th (1:4) plaster to the bottom of the pit , providing necessary invert with cement concrete (1:3:6) with stone chips as per direction , neat cement finishing to entire internal surface, top of pit covered with 100 mm th R.C.C slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6 mm th cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia R.C.C. manhole cover of approved make supplied , fitted and fixed in the slab with necessary fittings , necessary earthwork in excavation in all sorts of soil , filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.
i) With Pakur variety (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing with 1 st class brick work in cement mortar (1:4) including two 560 mm dia R.C.C. manhole cover (heavy duty ) of approved make supplied fitted and fixed in the 100 mm th R.C.C (1:1.5:3) top slab with necessary fitting , 20 mm th cement plaster (4:1) with neat cement finish to the internal surfaces and 15 mm th cement plaster (4:1) to the outside wall upto 200 mm below G.L. floor finished with 25 mm th grey artificial stone over 100 mm th R.C.C. (1:1.5:3) bottom slab including supplying fitting and fixing all necessary specials , fitting S.W. tees , C.I. foot rest etc. including excavation earth in all sorts of soil , shoring , bailing out and pumping out water as necessary , ramming , dessing the bed and refilling the sidesof the tank with earth , removing spoils , filling up the chamber with clear water , removing forign materials from the chamber and including constructig attached inspection pit as per approved drawing and connecting all necessary pipes , joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all cost of labour and materials.
For 50 users
i) With Pakur variety (SAIL/TATA/RINL)
Construction of circular soak well 2.5 M deep in all type of sandy soil with dry brick work upto 1.6 M from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.9 m from top with 20 mm th. Cement plastering (1:4) to inside face upto the depth of cement brick work , 15 mm th. cement plaster on outer face from top of well upto G.L. and 6 mm th. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.00 M of inside of the well with brick metal ( 50mm to 63 mm size ) including R.C.C. cover slab of 100 mm th with cement concrete (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C manhole cover (heavy type ) of approved make supplied , fitted and fixed in the cover slab with necessary fitting , making necessary arrangement for pipe connection , excavation of well including shoring, dewatering and removing the exess earth from the premishes as per direction complete in all respect with all cost of labour and materials .
With 250 mm th. dry brick work and 250 mm th. cement brick work (6:1) and 1.00 m inside dia.
SAIL/TATA/RINL
Labour charge for fitting and fixing UPVC pipe for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials , cutting pipes , cutting holes in walls or R.c. floor where necessary and mending good all damages excluding the cost of masonry or concrete work if necessary but including the cost of fitting and fixing holder bat clamps or for under ground work including cutting trenches upto 1.5 m and refilling the same complete as per direction of E.I.C
(A) Above ground i) 75mm dia
ii) 110 mm dia
(B) Under ground i) 110 mm dia
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
BOQ_2492366.xls
BOQ • 0.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].