Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.9 LQualified Make: zebronic
Model: Zebronics ZEB-U740 G S ROAD GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | Make: zebronic
Model: Zebronics ZEB-U740 | ₹8.9 L | L1 | Qualified |
| 2 | L2₹11.0 L+₹2.1 L (23.8%)Qualified Make: CyberPower
Model: CyberPower UT600E 0 EUREKA TOWER 2ND FLOOR CHANDMARI NEAR U TURN GUWAHATI KAMRUP ASSAM 781003 | KAMRUP METRO | ASSAM | 781003 | Make: CyberPower
Model: CyberPower UT600E | ₹11.0 L+₹2.1 L (23.8%) | L2 | Qualified |
| 3 | L3₹11.1 L+₹2.2 L (24.2%)Qualified Make: ELNOVA
Model: ELNOVA QT620 ALIGANJ LUCKNOW 2845 226024 INDIA | LUCKNOW | UTTAR PRADESH | 226024 | Make: ELNOVA
Model: ELNOVA QT620 | ₹11.1 L+₹2.2 L (24.2%) | L3 | Qualified |
| 4 | L4₹12.1 L+₹3.2 L (36.0%)Qualified Make: better power
Model: Make: Better Power, Model: Poweron 650 with 3 pin 0 BETTER POWER SERVICES PVT LTD A K AZAD ROAD REHABARI KAMRUP ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | Make: better power
Model: Make: Better Power, Model: Poweron 650 with 3 pin | ₹12.1 L+₹3.2 L (36.0%) | L4 | Qualified |
| 5 | Disqualified Make: Intex
Model: Intex- pro-725 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: Intex
Model: Intex- pro-725 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
29 Jun 2018, 1:00 pmClosed
Line Intractive UPS with AVR Average Turn Over of Last 3 Years 5 Lakh (s) Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 527 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/84 0.5/84 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for No No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NA - Name Of Lab NA - Address of Lab NA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rahul Dev Chakraborty
Consignee Detail at tender section of https:/nhm[dot]a ssam[dot]gov[dot]in 527 45 EMD Required No ePBG Required No
166104
GEM/2018/B/23680
Line Intractive UPS with AVR
Ludhiana, Punjab
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Average Turn Over of Last 3 Years 5 Lakh (s) Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 527 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/84 0.5/84 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for No No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NA - Name Of Lab NA - Address of Lab NA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rahul Dev Chakraborty | - | - | - |
| Consignee Detail at tender section of https:/nhm[dot]a ssam[dot]gov[dot]in 527 45 EMD Required No ePBG Required No | - | - | - |
Exempted
29 Jun 2018
2 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_166104.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .