Loading…
Loading…
Tender Value
₹2.4 Cr
EMD Value
₹2.4 L
Closing Date
13 Feb 2026, 5:00 pmClosed
Managing Director, APMSIDC
Plot No.9 Survey No.49 Auto Nagar, Mangalagiri
Construction of new Administrative Block & Mini Auditorium, lifts arrangements, renovation of class rooms and compound wall at Dr. A.R. Government Homeopathy Medical College at Rajamahendravara, East Godavari District
893852
9-2/APMSIDC/Technical/2025-26, dt.23-01-2026
OPEN - NCB
Civil Works
EAST GODAVARI, ANDHRA PRADESH
22 documents required · 22 mandatory
₹8,502
₹2.4 L
28 Feb 2026
30 Jan 2026
30 Jan 2026
Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete Brick masonry
Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete Reinforced cement concrete
Dismantling doors , windows and clear storey windows, Ventilators etc., ( wood or steel ) shutters including Chowkhats , architraves,hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., and overheads & contractors profit complete for finished item of work Not exceeding 3 sqm in area :
Earth work excavation for foundations (Mechanical Means) for buildings in ordinary soils and depositing on bank for all lifts and with an initial lead of 10m and up to 3m depth including all operational,incidental, labour charges such as shoring, sheeting, planking, strutting etc., and overheads & contractors profit complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308)
Plain Cement Concrete (1:4:8) (cement: fine aggregate: Coarse aggregate) for foundations using coarse aggregate 40mm size hard , machine crushed granite from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site including all charges for machine mixing and hire charges of concrete mixer, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and overheads & contractors profit complete for finished item of work. (APSS No. 402)
Plain Cement Concrete (1:5:10) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site including all charges for machine mixing and hire charges of concrete mixer, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and overheads & contractors profit complete for finished item of work. (APSS No. 402)
Filling with useful available excavated earth (excluding rock) with a lead of 50 m in trenches, sides of foundations and basement with initial lead in layers not exceeding 15cm thick, watering and ramming including cost and conveyance of water to work site and all operaitonal, incidental, labour charges, hire charges of T&P etc., and overheads & contractors profit complete for fnished item of work (APSS NO.309&310)
Filling with carted gravel in trenches,sides of foundations and basement with initial lead in layers not exceeding 15cm thick,watering and ramming including cost and conveyance of water to work site and all operaitonal,incidental, labour charges,hire charges of T&P etc., and overheads & contractors profit complete for fnished item of work(APSS NO.309&310)
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Footings
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Pedestals
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Plinth beams
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m :Columns:First Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m :Columns:Third Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m : Lintels:First Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m : Lintels:Third Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m :Wall- 230mm:First Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m : Roof Beams : First Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m : Roof Beams : Third Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m :Roof Slabs -125mm thcik : First Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 m :Roof Slabs -150mm thcik : Third Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) un supported height up to 3.66 mRoof Slabs -175mm thcik :Third Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site, centering using casurina ballies , bamboos , wooden reapers , runners , wood posts , wall plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402, 403 & 903) First Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site, centering using casurina ballies , bamboos , wooden reapers , runners , wood posts , wall plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402, 403 & 903) Third Floor
Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site, centering using casurina ballies , bamboos , wooden reapers , runners , wood posts , wall plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402, 403 & 903) Fourth Floor
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).un supported height up to 3.66 mBasement
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).un supported height up to 3.66 mSuper Structure-First Floor
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).un supported height up to 3.66 mSecond Floor
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).un supported height up to 3.66 mThird Floor
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).un supported height up to 3.66 mFourth Floor
Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, fly ash cement / lime solid blocks, water etc., to site, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) un supported height up to 3.66 m :First Floor
Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, fly ash cement / lime solid blocks, water etc., to site, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) un supported height up to 3.66 m:Second Floor
Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, fly ash cement / lime solid blocks, water etc., to site, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) un supported height up to 3.66 m:Third Floor
Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, fly ash cement / lime solid blocks, water etc., to site, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) un supported height up to 3.66 m:Fourth Floor
Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site including all charges for machine mixing, hire charges of concrete mixer, centering charges, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for bed blocks & hold fasts for finished item of work. (APSS No. 402)Second Floor
Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site including all charges for machine mixing, hire charges of concrete mixer, centering charges, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for bed blocks & hold fasts for finished item of work. (APSS No. 402)Third Floor
Plain Cement Concrete M 20 nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site including all charges centering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, centering charges, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for steps for finished item of work. (APSS No. 402)Third Floor
Reinforced Cement Concrete M 20 nominal mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including centering, shuttering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. First Floor
Reinforced Cement Concrete M 20 nominal mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including centering, shuttering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. Third Floor
Reinforced Cement Concrete M 20 nominal mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including centering, shuttering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for platforms and shelves. 50mm thick platforms / lofts: First Floor
Reinforced Cement Concrete M 20 nominal mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including centering, shuttering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for platforms and shelves. 50mm thick platforms / lofts:Third Floor
Reinforced Cement Concrete M 20 nominal mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including centering, shuttering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for platforms and shelves.25mm thick shelves:First Floor
Reinforced Cement Concrete M 20 nominal mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including centering, shuttering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for platforms and shelves.25mm thick shelves:Third Floor
Providing Thermo Mechanically Treated (TMT) (Fe 500 / Fe 500 D grade as per IS 1786-1979) of different diameters for RCC works including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126)First Floor
Providing Thermo Mechanically Treated (TMT) (Fe 500 / Fe 500 D grade as per IS 1786-1979) of different diameters for RCC works including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126)Third Floor
Providing Thermo Mechanically Treated (TMT) (Fe 500 / Fe 500 D grade as per IS 1786-1979) of different diameters for RCC works including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126)Fourth Floor
Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126)Third Floor
Ornamental ceiling plastering 12mm thick single coat in CM (1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) First Floor
Ornamental ceiling plastering 12mm thick single coat in CM (1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) Second Floor
Ornamental ceiling plastering 12mm thick single coat in CM (1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) Third Floor
Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work (SS 901,903 & 904) Basement
Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work (SS 901,903 & 904) First Floor
Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work (SS 901,903 & 904) Second Floor
Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work (SS 901,903 & 904) Third Floor
Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work (SS 901,903 & 904) Fourth Floor
Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing admixture confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 100ml per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903).(Third Floor)
PROVIDING SPECIALISED FIVE LAYER SYSTEM OF WATERPROOFING TREATMENT TO THE TERRACE WITH Roofcare-prc 5 Systems or equivalent ( ROOFCARE PRC 5 (Armstrong) / ZORICOAT PFC 5 (PMCC)/ POWER SAC 5 L (EBT)/ WATERSHIELD 5 LWC a). Ist Layer Black coloured chemcial treatment : Providing and application of one coat of High bonding, flexible bituminous polyurethane blended bituminous coating with – Roofcare prc 5 systems Confiming to ASTM-G 154 - 2000 or equavalent Ist Layer diluting with water at 1 : 1 ratio as a primer coat at a consumption of 200ml per Sqm. b). IInd Layer : Providing and laying of Fibre Mesh 40 GSM, with 1 Mtr width and 50mm overlap on the primed surface. c). IIIrd Layer Grey coloured coating : Providing and application of one coat of Acrylic rubberized elastomeric flexible waterproof grey coating with – Roofcare prc 5 systems ASTM-C 836 or equavalent or equavalent diluting with 50% of water at a consumption of 400ml per Sqm. d) IVth Layer white colured coating : Providing and application of one coat of High solid, cold applied, Fibre reinforced acrylic elastomeric waterproof membrane off white coating –Roofcare prc 5 systems Confiming to ASTM-G 154 -2000 or equavalent coating (add the water upto 200ml ) (Consumption of 350ml per Sqm ). e) Vth Layer super white reflective coating : Application of one coat of 100% pure acrylic solar reflective pure white coating withRoofcareprc 5 systems Confirming to ASTM -C 297 or equavalent solar refective coating diluting with 20% of water (Consumption of 300ml per Sqm ). Note : THE ABOVE TREATMENT WILL BE GUARANTEED FOR 5 YEARS
Flooring with non-skid red or white full body Ceramic floor tiles of size 300 mm x 300 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) First Floor
Flooring with non-skid red or white full body Ceramic floor tiles of size 300 mm x 300 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) Second Floor
Flooring with non-skid red or white full body Ceramic floor tiles of size 300 mm x 300 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) Third Floor
Flooring with non-skid Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) First Floor
Flooring with non-skid Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) Second Floor
Flooring with non-skid Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) Third Floor
Providing 18 mm to 20 mm thick Anti-skid Granite (Black) up to 2.43M (Stair case) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, full rounding the edges of treads , providing 3 grooves of size 2mm x 1mm for the full length of treads , polishing charges, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special) Third Floor : Treads of 0.30m wide :
Providing 18 mm to 20 mm thick Anti-skid Granite (Black) up to 2.43M (Stair case) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, full rounding the edges of treads , providing 3 grooves of size 2mm x 1mm for the full length of treads , polishing charges, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special) Third Floor :Risers of 0.15m height :
Providing skirting 10 cm height with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of Size 600 x 600 mm and thickness between 8-10 mm of any colour and finish in all shades and designs, length equal to flooring tiles, flushed to wall surface to set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and overheads & contractors profit complete for finished item of work.(APSS No.701 &707)Second Floor
Providing skirting 10 cm height with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of Size 600 x 600 mm and thickness between 8-10 mm of any colour and finish in all shades and designs, length equal to flooring tiles, flushed to wall surface to set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and overheads & contractors profit complete for finished item of work.(APSS No.701 &707)Third Floor
Providing dadooing with glazed full body porcelain wall tiles of size 300mm x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved pattern as approved by Engineer-in-Charge flushed to wall surface set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Second Floor
Providing dadooing with glazed full body porcelain wall tiles of size 300mm x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved pattern as approved by Engineer-in-Charge flushed to wall surface set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Third Floor
Providing dadooing with glazed red or white full body ceramic wall tiles of size 300 x 450 mm / 320 mm x 400 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge flushed to wall surface set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. First Floor
Providing dadooing with glazed red or white full body ceramic wall tiles of size 300 x 450 mm / 320 mm x 400 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge flushed to wall surface set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Third Floor
Providing plinth protection using plain Cement Concrete general purpose tiles conforming to IS: 13801 using aggregates, cement, pigments of size 300 x 300 mm and thickness 20 mm of any shade for a width of 1200mm set over base coat of cement mortar (1:6), 12 mm thick using screened sand over PCC(1:5:10) bed 100mm thick along with drain constructed with 225 mm thick walls using fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. and plastering 12mm thick two coats with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) for brick masonry drain, laying of tiles in between basement of the building and brick wall and as directed by the Engineer - in - charge including cost and conveyance of all materials to site, all labour charges like mixing of cement concrete, laying, curing, overheads & contractor profit etc., complete for finished item of work.
Reinforced cement concrete (1:5:10) proportion (Cement: fine aggregates: coarse aggregate) using 40mm size (SS5) hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site including centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., shuttering, machine mixing, laying concrete, lifting concrete manually , vibrating, curing, etc., and overheads & contractors profit complete as per drawings but excluding cost of steel and it's fabrication charges for finished item of work (APSS NO. 402 & 403) for dummy columns. Fourth Floor
Supplying and fixing of stainless steel (grade 304) hand railing as per approved drawing with top rail of 50mm dia pipe and 2mm thick medium class and vertical posts of 25mm dia and 1.6mm thick medium class 1 No for each step fixed with base plate of 25mm dia using bonding agent and anchor fastner and welding, drilling of 25mm dia holes with pneumatic compressor for fixing railing, buffing, polishing all members of the railing thouroughly , lacquer finishing to present seamless finish including cost and conveyance of all materials, electrodes, welding charges, cost of all consumables, labour charges , overheads & contractors profit etc., complete for finished item of work.
Supplying and fixing of stainless steel (grade 304) railing for ramp as per approved drawing with top rail of 50mm dia pipe and 2mm thick medium class fixed in to wall with 25mm dia pipe of 0.30m length @ 1m centre to centre and welding, buffing, polishing all members of the railing thouroughly , lacquer finishing to present seamless finish including cost and conveyance of all materials, electrodes, welding charges, cost of all consumables, labour charges , overheads & contractors profit etc., complete for finished item of work.
Supplying and fixing of stainless steel (grade 304) grip bars 200mm length bars in toilets as per approved drawing with 25mm dia pipe with base plates 2 Nos., buffing, polishing thouroughly , lacquer finishing to present seamless finish including cost and conveyance of all materials, labour charges , overheads & contractors profit etc., complete for finished item of work.
Providing 110 mm Dia ISI marked PVC down water take pipes with single socket , 2.5mm thick 4.0 kg/sq.cm pressure of ISI marked including cost of necessary PVC Bends, couplers, shoes, iron / PVC clamps and all other accessories and fixing in position including cost and conveyance of all materials, operational & incidental charges including all labour charges for fixing at site etc., and overheads & contractors profit complete for finished item of work. (APSS No. 1328)
Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides, fixing 1mm thick mat finish laminated sheet to full width and height of the flush shutter both sidesincluding cost and conveyance to site of teak wood frame, flush shutter, laminate sheet including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. Rubber / Nylon door stop bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1200mm x 2100mm)
Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides fixing 1mm thick mat finish laminated sheet to full width and height of the flush shutter both sides including cost and conveyance to site of teak wood frame, flush shutter, laminate sheet including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long , 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 1 No. door stopper and 1 No. Rubber / Nylon door stop bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1000mm x 2100mm)
Providing and fixing factory made uPVC white colour sliding glazed window comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage ofwater etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge inclusive of cost of Single / double glass panes, wire mesh and silicon sealent . Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mmboth having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension
Providing and fixing factory made uPVC white colour fixed glazed windows / Ventilators comprising of uPVC multi chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket,G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profileof frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge inclusive of cost of Single / double glass panes and silicon sealant. Note: For uPVC frame, sash and mullion extruded profiles minus 5%tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted. But, no extra payment on this account shall be made. Fixed windows / Ventilators made of (small series) frame 47 x 50mm & mullion 47 x 68 mm both having wall thickness of 1.9 ±0.2 mm and single glazing bead of appropriate dimension.
Supply and fixing factory made solid Wood Polymer Composite (WPC) single extruded Door Frame section of 63.5x100 MM .The two Vertical members are to be joined together with the horizontal member using 8x75 MM long MS Star full thread screws to be used with reverse forward speed control hand drilling machine. The ready/assembled door frame is fixed to the wall using hold fast or bolt fasteners. A minimum of 4 No.s of screws to be provided for each vertical member & minimum 2no.s for horizontal member .. etc. complete as per manufacture specification and direction of Engineer-incharge including conveyance of all materials, labour charges for fixing, overheads & contractors profit complete for finished item of work.
Providing and fixing 28 -30 MM thick solid Wood Polymer Composite (WPC ) single extruded door shutter with 3MM top and bottom rigid layer with an overall density of 750kg/Cum. It will be fixed to the frame using 3 inch /4 inch hinges. Aminimum of 4 hinges will be required for fixing the door with the frame complete as per direction of Engineer – in-Charge, manufacture specification and drawing including ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250 mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208),1 No. Rubber / Nylon door stop bushes including labour charges for fixing the shutter to frame etc., including overheads & contractors profit complete for finished item of work for door of size 750mm x 2100mm
Supplying and fixing of MS doors, grill to windows / in open court yards using MS angles, flat, square bars including cost and conveyance of all materials, cutting, bending, welding, all operational charges, labour charges, overheads and contractor profit etc., complete for finished item of work.
Supply & application of one coat water based cement primer of interior grade I and two coats of acrylic emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for internal walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc.,and overheads & contractors profit complete for finished item of work in all floors.
Supply & application of one coat water based cement primer of exterior grade II and two coats of acrylic exterior emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for exterior walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc.,and overheads & contractors profit complete for finished item of work in all floors.
Painting two coats with synthetic enamel paint Grade-II VOC (Volatile Organic Compound) content less than 50 grams/litre over primer coat of red oxide to new iron work including cost and conveyance of all materials to site, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors. (SS No. 1201, 1212 & 1207).
Providing and fixing in true horizontal level 13 mm - Mineral Fiber Ceiling tile of 595 x 595 (Square edge Fissura fine model) using hot dipped Galvanized Steel section exposed surface with pre-coated capping, main Tee of size 24 x 32 mm at every 1200 mm c/c maximum and rotary stitched cross tee of size 24 x 27 mm at every 600 mm c/c and sub-cross tee of size 24 mm x 25 mm at 1200 mm c/c and wall angle of size 19 x 19 mm fixed to periphery of the wall and the above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick pre-straightened GI Wire including cost and conveyance of all materials and labour charges such as cutting , fixing of standing of frame work exposing roof making, overheads & contractor profit etc., complete for finished item of work in all floor in all floors.
Supplying and fixing 50mm dia nominal bore Medium Grade properties & weight as per IS 1239 ISI mark MS Tube for fixing of GI Sheet including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., complete for finished item of work in all floors for stair case head room roof.
Supplying and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with G.I ‘J’ bolts & nuts 8 mm dia with bitumen & G.I limpet washers filled with white lead & including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (up to a pitch of 600) etc., complete, excluding the cost of purlins, rafters, trusses including cost and conveyance of all materials , labour charges , overheads and contractors profit etc., complete for finished item of work in all floors.
Supply & application of two coats of acrylic emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for internal walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc.,and overheads & contractors profit complete for finished item of work in all floors.
Supply & application of two coats of acrylic exterior emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for exterior walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc.,and overheads & contractors profit complete for finished item of work in all floors.
Constructing 904.0 mm (3’0”) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½” thick both inside and outside fitted with 20” dia RCC manhole covers and frames including excavating pits up to a depth of 904 mm (3'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.
Constructing 904.0 mm (3’0”) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½” thick both inside and outside fitted with 20” dia RCC manhole covers and frames including excavating pits up to a depth of 1524 mm (5'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber upto 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg including cost and conveyance of all materials like cement, sand, bricks, water etc., to site and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.
Supplying and fixing 150.00mm x 100.00mm gully trap 1st class with CI grating and constructing single brick masonry wall chamber of size 20" x 14" x 12” in CM (1:6) prop. Over a CC (1:5:10)prop. bed, and plastering 12mm thk. in CM (1:4) prop. both inside and outside surfaces and fitted with RCC cover 3" thick as directed by Engineer-in-charge including cost and conveyance of all materials to site, labour charges etc., complete for finished item of work.
Supplying and fixing of 4" (101.6 mm ) Nahany Trap with Jali UPVC/SWR Pipe fittingsas per site requirements with standard practice for all floors including cost and conveyance of all materials to site, labour charges , overheads & contractors profit etc., complete for finished item of work.
Supplying and fixing European Water Closet of 1st quality conforming to IS:2556-Part-2-1973 of white glazed with 'S' trap,supplying and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996 and 10 litres capacity single flush PVC low level cistern with internal components and fixed using required size of nails and screws, angle stop cock 12.70mm dia. first quality Indian make heavy duty, 12mm PVC connections with brass union nuts CP coated including cost and conveyance of all materials to site, overheads & contractors profit etc., complete for finished item of work for all floors.
Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 31.75mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work
Supplying and fixing NP soap dish heavy type of approved make ISI quality with NP screws etc., complete including cost and conveyance of all materials, labour charges for fixing , overheads & contractors profit for finished item of work in all floors
Supplying and fixing TV shape mirror with plastic frame of size 609.6mm x 457.2mm , plywood back with NP screws 1st quality including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work in all floors.
Supplying and fixing of 25.4mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work.
Supplying and fixing NP bib taps of size 12.70mm dia of Indian make heavy duty (long body) as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , overheads & contractors profit complete for finished item of work in all floors.
Supplying and fixing white glazed flat back half stall urinals of size 590 mm x 375 mm x 390 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 31.75 mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges etc., overheads & contractors profit complete for finished item of work for all floors.
Supplying and fixing of SWR PVC pipes (as per ISI standards) 6 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges etc.complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)For 75mm dia
Supplying and fixing of SWR PVC pipes (as per ISI standards) 6 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges etc.complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)For 110mm dia
Supplying and fixing of SWR PVC pipes (as per ISI standards) 6 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges etc.complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)For 160mm dia
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.22.20mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.28.60mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.34.90mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.41.30mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.54.00mm OD pipe
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.25mm Dia
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.40mm dia
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.50mm dia
Providing and placing on terrace (at all floor levels) polyetheylene water storage tank with double layer approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet and outlets and over flow pipes but without fittings and base support for tanks
Supplying and fixing of 16mm to 20 mm thick polished marble slab partitioins of size 4' 0" x 2' 0" for urinals including full rounding the edges , fixing in position, polishing, including cost and conveyance of all materials and labour charges , overheads & contractors profit complete for finished item of work for all floors.
Construction of brick masonry support for GI pipe of size 304.80mm x 228.60mm x 228.60 mm in CM (1:8) prop including plastering and finishing with 12mm thick in CM (1:5) including cost and conveyance of all materials and all labour charges, overheads & contractors profit complete for finished item of work for all floors.
Supply and fixing of ISI 25mm outer dia (2.00 to 2.20)mm thickness, heavy grade with IS:9537 part 3 FRLS rigid PVC pipe (ISI marked) concealed in Roof Slabs with all required PVC Junction Boxes confirms to IS : 3419 and all accessories including and labour charges etc., complete. Makes : Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/AKG.
Supply and Fixing of 25mm outer dia (1.60 to 1.80)mm thicknes medium grade with IS:9537 part 3 FRLS rigid P.V.C. pipe (ISI marked) concealed in wall with all required MS junction boxes and all accessories including masonary work for light, bell, fan, and separate plug point with hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges etc., complete. Makes : Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/AKG
Supply and Fixing of 32mm outer dia (1.90 to 2.10)mm thicknes medium grade with IS:9537 part 3 FRLS rigid P.V.C. pipe (ISI marked) concealed in wall with all required MS junction boxes and all accessories including masonary work for light, bell, fan, and separate plug point with hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges etc., complete. Makes : Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/AKG
Supply and Fixing of 20mm outer dia (1.40 to 1.55)mm thicknes medium grade with IS:9537 part 3 FRLS rigid P.V.C. pipe (ISI marked) concealed in wall with all required MS junction boxes and all accessories including masonary work for run of mains including all labour charges etc., complete. Makes : Precision/ Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/AKG
Supply and Fixing of 25mm outer dia (1.60 to 1.80)mm thicknes medium grade with IS:9537 part 3 FRLS rigid P.V.C. pipe (ISI marked) concealed in wall with all required MS junction boxes and all accessories including masonary work for run of mains including all labour charges etc., complete. Makes : Precision/ Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/AKG
Supply and fixing of fan hook in RCC slab of 12/15mm dia MS Rod while laying the slab.
Supply and erecting MS Galvanished fan hook box with hook in RCC slab including all Labour charges etc., complete.
Wiring with 2 runs of 22/0.3mm ( 1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable (ISI marked) in existing pipe with 6A Modular switch (ISI marked) with cover plate, Ceiling rose/BH/ SBH, including all labour charges etc., complete for Light, Bell, Fan and Exhaust Fan points etc., complete. (for Non Residential Building).Makes of wires:- Finolex / RR kabel/Havells/KEI/Polycab/ Goldmedal/GM/Million. Makes of switches:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)
Wiring with 2 runs of 22/0.3mm ( 1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable (ISI marked) in existing pipe with 2 Way 6A Modular switch (ISI marked) with cover plate, Ceiling rose/BH/ SBH, including all labour charges etc., complete for 2-way light and fan points/stair case light points etc., complete. (for Non Residential Building) Makes of wires:- Finolex/RR kabel/ Havells/ KEI/Polycab/ Gloster/V-Guard/HPL/GM/ Million/Goldmedal/Anchor.Makes of switches:- Legrand Myrius / Crabtree verona/L&T/ HPL/ Schneider Livia/GM (Zicono/Four Five)/C&S/Goldmedal (Curve)/Million Mway/Logus Platina/ Panasonic Vision/ Salzer S90 series/Anchor-Roma.
Supply and Fixing of one module PVC blanking plate (safety dummy plate for empty module) for closing the dummy blank modules in the modular switch board for ensuring safety etc., complete. Makes:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)
Supply and Fixing of 6 Amps modular type (ISI marked) switch, and 6 A 3/2 pin Modular type socket with cover plate on a common switch board including giving all connections and all labour charges etc., complete. Makes of switches/sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)
Wiring with 2 of 22/0.3mm ( 1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable (ISI marked) in existing pipe with 6A (ISI marked) modular type switches and 6A, 3/2 pin modular type socket with cover plate fixing on existing, separate modular switch box including all labour charges etc., complete. Makes of wires:- Finolex / RR kabel/Havells/KEI/Polycab/ Goldmedal/GM/Million. Makes of switches/sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)
Wiring with 2 of 22/0.3mm ( 1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable (ISI marked) in existing pipe with 2 No of 6A (ISI marked) modular type switches with 2 No of 6A, 3/2 pin modular type sockets with cover plate on suitable hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges, giving all connections etc., complete for LABs & Computer Use.Makes of switches/sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)
Supply and fixing of 4 No of 6A (ISI marked) modular type switches with 4 No of 6A, 3/2 pin modular type sockets with cover plate on suitable hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges, giving all connections etc., complete for LABs & Computer Use. Makes of switches/sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)
Supply and fixing of 16A/6A, 2 in one, modular type socket with 16A switch (ISI marked) modular type with cover plate on existing modular metal switch box including all labour charges, giving all connections etc., complete. Makes of Switches/Sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal (GIFA)/ Million (M-VEE)
Supply and Fixing of of 20A, modular type power socket outlet (ISI marked) with front cover plate on existing modular metal switch box including all labour charges, giving all connections etc., complete with following configurations1) 20A Socket - 1 No Makes of Switches/Sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/ Million (M-VEE)
Supply and Fixing of of 16A/6A, 2 in one, modular type power socket outlet with 16A switch (ISI marked) modular type and 2 No of 6A modular type sockets with 6A modular type (ISI marked) switch control with front cover plate oon hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges, giving all connections etc., complete with following configurations 1) 16A Socket - 2 No 2) 16A Switch - 2 No 3) 6A socket - 2 No. 4) 6A switch - 2 No Makes of Switches/Sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/ Million (M-VEE)
Supply and Fixing of of 16A/6A, 2 in one, modular type power socket outlet with 16A switch (ISI marked) modular type and 1 No of 6A modular type sockets with 6A modular type (ISI marked) switch control with front cover plate on hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges, giving all connections etc., complete with following configurations 1) 16A Socket - 1 No 2) 16A Switch - 1 No 3) 6A socket - 1 No. 4) 6A switch - 1 No Makes of Switches/Sockets:- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/ Million (M-VEE)
Supply and run of 1 of 22 /0.3mm (1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing pipe for earth continuity including all labour charges etc., complete. Makes of wires:- Finolex / RR kabel/ Havells/KEI/Polycab/ Goldmedal/GM/Million
Supply and run of 3 of 2.5 sq.mm (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing MS conduit pipe for individual ligting circuits including labour charges etc., complete as required for light circuits,Geysers, plug points.Makes of wires:- Finolex / RR kabel/ Havells/KEI/Polycab/ Goldmedal/GM/Million.
Supply and 3 runs of 4.0 sq mm (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing conduit pipe for run of mains including labour charges etc., complete as required including labour charges for 16A sockets & AC plugs.Makes of wires:- Finolex / RR kabel/ Havells/KEI/Polycab/ Goldmedal/GM/Million
Supply and run of 5 of 6 Sq mm (phases, neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing MS conduit pipe for circuits including labour charges etc. complete as required for run of mains from Lighting panel board to TPN DB'S with pin type lugs and connections. [for LDBs] Makes of wires:- Finolex / RR kabel/ Havells/KEI/Polycab/ Goldmedal/GM/Million
Supply & run of 5 of 10.0 Sqmm (phases, neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in the existing conduict pipe for run of mains from Power panel board to TPN DB"s with pin type lugs and connections etc., complete. [for PDBs] Makes of wires:- Finolex / RR kabel/ Havells/KEI/Polycab/ Goldmedal/GM/Million
Supply and Fixing of single phase DB in sheet steel enclosure as per IS 8623; IS 13032; IEC 61439-3 with metalic plug and socket with 1 No. 20/32A,10KA 'c' curve SPMCB control including labour charges and giving connections etc., complete concealed in wall. Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager-Novello+/Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ L&T-AU .
Supply and fixing of TPN 4 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+12 Module) with provision to accommodate the RCCB & FP MCB as incomer and suitable for single pole outgoing MCB's in sheet steel enclosure with 40A, 10 KA breaking capacity 'c' curve 4 pole MCB with 40A, 30mA, and 12 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. (LIGHTING DB). Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/ L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Crabtree-Xpro/L&T-AU
Supply and fixing of TPN 6 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+18 Module) with provision to accommodate the ELCB incomer and suitable for single pole outgoing MCB's in sheet steel enclosure with 40A,10 KA breaking capacity 'c' curve 4 pole MCB as incomer and 18 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. (LIGHTING DB). Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ L&T-AU
Supply and fixing of TPN 4 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+12 Module) with provision to accommodate the ELCB incomer and suitable for single pole outgoing MCB's in sheet steel enclosure with 63A, 10 KA breaking capacity 'c' curve 4 pole MCB as incomer and 12 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. (POWER DB). Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ L&T-AU
Supply and fixing of VTPN DB, 4 way vertical type MCCB distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, suitable to accommodate MCCB as incomer and single/three pole MCBs as outgoings with 125A, 4 Pole MCCB adjustable, confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release as incomer with 3No of 40/63A, 10 KA TP MCBs 'c' curve and 3 No, 6-32A, 10 kA SP MCBs 'c' curve as outgoing including making connections and labour charges etc., complete concealed in wall. Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ L&T-AU
Supply and fixing of Cable adopter/Cable end box with cover suitable for 4-way TPN, IP-43 protection DBs including, massanory work etc., complete for concealed mounting. Makes: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange
Supply and fixing of Cable adopter/Cable end box with cover suitable for 6-way TPN, IP-43 protection DBs including, massanory work etc., complete for concealed mounting. Makes: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange
Supply and Fixing of 32-40A, 25/36 KA Four Pole MCCB with suitable sheet steel enclosure on wall for Power Supply in Lift Machine Room including all Labours charges etc complete with connections. [for Lift Machine Room power supply] Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Crabtree-Xpro/L&T-AU
Supply and Fixing of 6-32A, 10 KA breaking capacity 'c' curve double pole MCB in sheet steel DP enclosure with IP 20 Protection etc., complete as per IS 8623; IS 13032; IEC 61439-3 including making connections etc., complete on wall. [for UPS Input/Output control etc.,] Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ L&T-AU
Supply and Installation of 63A FP, MCCB, 25KA on wall with suitable sheet steel enclosure with cable end boxes including all labour charges etc complete with connections. Make: L&T- D sine / Schneider-CVS/ Legrand (DP X3/DRX)/ Siemens-3VL/ C&S-Winbreak
Supply and Installation of 125A FP, MCCB, 25KA on wall with suitable sheet steel enclosure with cable end boxes on angle iron frame work including all labour charges, massonry work etc complete with connections. Make: L&T- D sine / Schneider-CVS/ Legrand (DP X3/DRX)/ Siemens-3VL/ C&S-Winbreak.
Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C.Chamber of 400m x 400m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)
Providing independent earthing for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 40mm dia G.I Pipe of 2.5 mtr length connected with reducer providing G.I funnel with wiremesh as per National Electric Code including C.C.Chamber of size 400m x 400m x 400mm covered with R.C.C. Slab filling with salt and charcoal giving earth connection from electrode with Copper strip of 25mm x 5mm x 200mm length to be bolted with nut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to Copper strip with all accessories and labour charges complete as per IS specification 732/1982 (Part II).
Supply and Run of 40mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete
Supply and Run of No. 8 SWG copper wire including cost of all accessories and labour charges etc., complete.
Supply and Run of 25mm x 3mm copper strip including cost of all accessories and labour charges etc., complete.
Supply and Fixing of 20-24W, not less than 1100mm length LED batten light with extruded alluminium / CRCA housing and polycarbonate cover, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV, THD<15%, with high power LEDs having efficacy of ≥ 120 lumens / watt with inbuilt and replacable driver with earth connection brought outside and frosted cover CCT: 3000K - 5700K, minimum CRI>70 etc., complete including fixing on wall / Ceiling with PVC/TW round blocks with all accessories including giving connections and all labour charges etc., complete with 5 years warranty.Makes: a) Luminaire make : Phillips / GE-Venture / Crompton / Wipro / Bajaj / Havells b) LED make : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/LG
Supply and transportation of 60W LED High Bay Luminaire with high power COB LED made of pressure diecast aluminum housing with powder coated, supply input voltage 120 - 270 V AC, P.F > 0.90, high power LEDs, having system efficacy >120 lumens/watt and junction temperature < 70°C, with ingress protection IP66, IK05, Driver surge protection 4KV, in-house additional surge protection ≥ 5KV with wide/narrow beam optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty. a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton / Wipro / Bajaj / Havells b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/LG
Supply, transportation and fixing of 7W LED COB Spot Light, suitable for Recessed mounting made of diecast alluminium body with powder coating, with Driver, operating voltage range of 150 to 265 Volts AC, CCT: 3000K - 5700K, minimum CRI>70 including fixing to the ceiling with necessary mounting arrangement cost of all accessories and giving connections etc., complete with 5 years warranty.a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton / Wipro / Bajaj / Havells b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/LG
Supply and Fixing of batten holder/angle holder on existing block with 5W LED Lamp with input voltage 90 to 300V, Colour temparature 3000k - 6500k, Beam angle 170 - 220 degrees, B22 base and all labour charges etc., complete. In lieu of ceiling rose. Makes: Phillips /Crompton / Bajaj / Havells / GM/HPL/Syska /GoldMedal
Supply and fixing of buzzer on 4"x4" decolam block including giving connections, cost of all accessories and labour charges etc., complete. Makes: GM / Gold Medal / Million / Vimal / Anchor
Supply and fixing of Remote bell including giving connections cost of all accessories and all labour charges etc., complete. Makes: GM / Gold Medal / Million / Vimal / Anchor
Supply and Transportation of 48" (1200mm) Sweep 5 star rated Ceiling Fan , with double ball bearings, air delivery more than 200 cubic meter/min but without Regulator.Makes : Crompton HS Plus / Havells ES PLUS/Orient Energy Star.
Supply and Transportation of 36" (900 mm) Sweep Ceiling Fan , with double ball bearings, but without Regulator. Makes : Crompton High Speed / Havells Velocity / Orient Summer King
Supply and fixing of Modular type 2- Module, Electronic fan regulator hum free step type socket size in the existing switch board. Makes :- Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/ Goldmedal(GIFA)/ Million (M-VEE)
Labour charges for fixing of ceiling fan including transportation and giving connections with 23/0060 size, 3 core round flexible copper wire leads of make Finolex / RR kabel/ Havells/KEI/Polycab/ Goldmedal/GM/Million etc complete
Supply and erecting 19/20mm steel tube down rod of 0.6 mt length with bolts & nuts duly painted with matching colour of fan complete
Supply and Transportation and fixing of 16" (400mm) Wall mounted Fan. Makes: Crompton High Flow / Bajaj Elite / Havells Swing Premia gold / Orient Wall 45
Supply and Transportation of 12" (300mm) Light duty exhaust fan with metalic blades and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air- DSP / Orient hill air
Supply and Transportation of 12" (300mm) ISI, 900 RPM Heavy duty exhaust fan with metallic blades with Mark. Makes: Crompton / Almonard / Havells Turbo Force
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete
Supply and fixing of louver shutter suitable for 12" Exhaust fan including all labour charges etc complete with connections and colouring matching to the wall with enamel paint.
Supply, Transportation and Fixing of 60W LED Street light Luminaire made of pressure diecast alluminium body with powder coated, having protective toughned glass, supply Input voltage 120-270 V AC, P.F>0.90, high power LED's having system efficacy>120 lm/W and junction temprature<70°C, with Ingrees protection IP66, Luminaire performance complies to IS 10322 (Part 5/Sec-3), Driver surge protection 4KV, external Surge protection 10 KV with optics distribution, THD< 10% at 110 Volts AC, driver efficiency >90%, CCT:3000K-5700K, minimum CRI>70, etc., complete including fixing of luminaire on wall/Pole with 1.0 mt of 40mm dia GI pipe bracket and anti-tilting MS flat, 3 core 1.5 Sq.mm sheathed flexible round copper cable including all labour charges and giving connections etc., complete with 5 years warranty. a) Luminaire make: Wipro(Skyline)/Philips (Green line) / GE-Venture / Crompton(Neo series) / Bajaj (Edge) / Havells (Endura series) b) LED make:Philips Lumileds/ Cree/Nichia/ Osram/Samsung/LG LEDs
Supply Installation Testing & commissioning of free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated/epoxy/PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (Panel shall be fabricated from reputed and branded manufacturers approved by dept and having CPRI approval with CPRI test certificates). Incomer :- 250A Four Pole, MCCB of adjustable, confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 1 No. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL Outgoing feeders:- 125A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted with separate individual neutral connector link. - 6 Nos. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL 63/60A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted with separate individual neutral connector link. - 4 Nos. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL Metering:- Supply and Fixing of (0-500) V range Volt meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves/channel etc., as required - 1 No. Make:Conzerve/Elmeasure/ Meco/ HPL/L&T/ Socomec Supply and Fixing of CT operated direct reading type Ammeter, below 500A, on existing panel , making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required - 1 No. Make: Conzerve/ Elmeasure/Meco/HPL/ L&T/ Schneider/AE/ Socomec Supply and Fixing of Current Transformer, from 200 / 5 to 400/5 Ratio, 10 VA , class 1 accuracy with all necessary support in existing panel including connection etc. as required - 3 No. Make: Kappa/L&T/ Seimens/ C&S/ Schneider Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp Red, Yellow & Blue Colour with integral circuit, terminal block, including connection etc. as required - 3 No of approved make Supply and Fixing of selector switch for voltmeter (4 position) including making connection etc. as required - 1 No. Make: L&T / C&S/ Salzer/HPL Supply and Fixing of CT linked selector switch of 10 A for Ampere meter (4 position) including making connection etc. as required - 1 No. Make: L&T/C&S/Salzer/ HPL 10 kA - 6-32A range SP MCBs - 6 No. Make: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Crabtree-Xpro/L&T-AU Bus Bars:- Supply and fixing of Electrolytic grade aluminium bus bars by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves For Bus Bars vertical & horizontal, Phases & Neutral equal sizes of 40mm x 8mm x 4R and for sectional bus bars and extended links to MCCBs shall be more than or equal to the ratings of MCCBs Control wiring, Earth Bus Bar, Door Loop earhtings, Labour charges for errection of switch gears, panels boards including all labour charges etc with connections for finished items of works including transportation charges.
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster/Finecab / Polycab /RR Kabel 3.5 core, 25 Sq.mm
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster/Finecab / Polycab /RR Kabel 3.5 core, 50 Sq.mm
Earth work excavation of Trench in hard ground soil, laying of U.G cables upto 50 Sq,mm on sand cushion covering the cable with bricks and back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
Labour charges for run of U.G cables upto 50 sq.mm on wall with necessary fixing arrangments such as saddles, clamps etc., as directed by department including cost and conveyance of all materials etc., complete.
Supply and Laying NP2 class RCC hume pipe with collars of following sizes for laying at the road crossings for the UG cables. 150 mm dia Hume pipe
Supply, installation, testing and commissioning of the following capacity on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1:2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / single phase output with, all accessories and labour charges etc., complete excluding batteries. Makes: Numeric/APC/Fuji Electric 10.0 KVA , 192/240V DC UPS with Isolation transformer
Supply and fixing of 12V, 42 AH SMF Battery with 3 years Warranty, including wire leads, connections etc complete. Makes: Quanta / Exide
Supply and providing of powder coated, corrosion free MS battery rack of approved make suitable for erecting for the following number and sizes of batteries upto 5 to 10 batteries (42 AH)
Supply, Transportation, Installation, Testing and Commissioning of 315 KVA TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (PartI to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under. Makes : Makes:Schneider/Kirloskar/Voltamp/ Esennar/ Toshiba/ KPEL/ Powertech /SSE / THOTA / Vajra 1. Quantity : 1 2. Rated KVA:315KVA 3. Service & Location: Continuous Outdoor Distribution Transformer 4. Mounting: Plinth. 5. Wound: Copper Double wound 6. Type: Core type oil immersed 7. Cooling: ONAN 9. Vector Group: Dyn 11 10. Primary Connection: Delta 11. Nominal Voltage / Current: _ 12. Highest system Voltage: 12000V 13. Primary Frequency :50 HZ +/- 3% 14. Number of Phases: 3 15. Primary wires: 3 16. Secondary connection: Star 17. Secondary Volts / Current : 433V 18. Secondary phases: 3 19. Secondary wires: 4 20. Taps on primary winding for primary voltage variation: +5% to - 10% in steps of 2.5% of 7 position (6 Steps) 21. Terminal arrangement. a. HV: HT terminal box as per the site condition. b. LV: Cable box suitable to receive ---------- --Sq.mm XLPE cable 22. LV: One separate terminal for earthing. 23. Total Losses at 50% Loading [Watts] [Max] --- as per IS 24. Total Losses at 100% Loading [Watts] [Max]--- as per IS 25.Percentage Impedance at 75 deg. C at -----as per IS 26. No Load current: Less than 2% of full load current. 27. Standard Fittings & Accessories. a. Rating and terminal marking plate: One b. Lifting Lugs: Two c. Off-circuit tap switch: One. d. Earthing Terminals : Two e. Radiators (Attachable): Adequate f. Explosion vent with Diaphragm : One g. Conservator with Drain plug: one h. Oil filling hole with cap :One i. Oil level indicator: One j. Dehydrating Silica gel Breather: One k. Terminal Arrangement: HV With Terminal Box l. Terminal Arrangement: LV Cable Box m. Separate Neutral Bushing : One n. Drain cum filter valve with blanking plate: One o. Air release device: One p. Thermometer Pocket: One q. Four: Unidirectional flat rollers r. One :10Cm dial thermometer (Rigid stem type
Supply, Transportation, Installation and Commissioning of 11KV, 630A, 25 KA Outdoor type Load Break Switch as detailed below with suitable CC foundation and 2 Nos GI pipe earthing with brick masonry chambers etc., complete for finished item of work. Makes: As per list of ecommended brands. a) Load break switch: 11KV,630A, 25 KA with fuse trip, earth switch, manually operated spring charged mechanism with 2 no + 2 NC. b) HT HRC fuse upto 63A - 3 nos. c) Bus bar connection.d) Indication lamps.e) Manual trip Push button Make:ABB/ Megawin/Amara Raja/L&T
Supply and Transportation of 3C X 120 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI /Polycab/Gloster/RR Kabel/RPG
Supply and Making heat shrinkable type indoor/ outdoor/straight through terminations/joint kit of approved make suitable for XLPE insulated 33 KV cable, with required components, preparation of cable ends, testing etc. as required of following sizes. Makes: Raychem /M seal/ Denson/ Multy/ Transeal Hongshang 3Core 95/120/150/185 sq mm INDOOR kit
Supply and Making heat shrinkable type indoor/ outdoor/straight through terminations/joint kit of approved make suitable for XLPE insulated 33 KV cable, with required components, preparation of cable ends, testing etc. as required of following sizes. Makes: Raychem /M seal/ Denson/ Multy/ Transeal Hongshang 3Core 95/120/150/185 sq mm OUTDOOR kit
Supply Installation Testing & commissioning of free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated/epoxy/PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (Panel shall be fabricated from reputed and branded manufacturers approved by dept and having CPRI approval with CPRI test certificates). Incomer :- 250A Four Pole, MCCB of adjustable, confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 1 No. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL Outgoing feeders:- 125A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted with separate individual neutral connector link. - 6 Nos. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL 63/60A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted with separate individual neutral connector link. - 4 Nos. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL Metering:- Supply and Fixing of (0-500) V range Volt meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves/channel etc., as required - 1 No. Make:Conzerve/Elmeasure/ Meco/ HPL/L&T/ Socomec Supply and Fixing of CT operated direct reading type Ammeter, below 500A, on existing panel , making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required - 1 No. Make: Conzerve/ Elmeasure/Meco/HPL/ L&T/ Schneider/AE/ Socomec Supply and Fixing of Current Transformer, from 200 / 5 to 400/5 Ratio, 10 VA , class 1 accuracy with all necessary support in existing panel including connection etc. as required - 3 No. Make: Kappa/L&T/ Seimens/ C&S/ Schneider Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp Red, Yellow & Blue Colour with integral circuit, terminal block, including connection etc. as required - 3 No of approved make Supply and Fixing of selector switch for voltmeter (4 position) including making connection etc. as required - 1 No. Make: L&T / C&S/ Salzer/HPL Supply and Fixing of CT linked selector switch of 10 A for Ampere meter (4 position) including making connection etc. as required - 1 No. Make: L&T/C&S/Salzer/ HPL 10 kA - 6-32A range SP MCBs - 6 No. Make: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Crabtree-Xpro/L&T-AU Bus Bars:- Supply and fixing of Electrolytic grade aluminium bus bars by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves For Bus Bars vertical & horizontal, Phases & Neutral equal sizes of 40mm x 8mm x 4R and for sectional bus bars and extended links to MCCBs shall be more than or equal to the ratings of MCCBs Control wiring, Earth Bus Bar, Door Loop earhtings, Labour charges for errection of switch gears, panels boards including all labour charges etc with connections for finished items of works including transportation charges.
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster/Finecab / Polycab /RR Kabel 3.5 core, 25 Sq.mm
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster/Finecab / Polycab /RR Kabel 3.5 core, 50 Sq.mm
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster/Finecab / Polycab /RR Kabel 3.5 core, 185 Sq.mm
Earth work excavation of Trench in hard ground soil, laying of U.G cables upto 50 Sq,mm on sand cushion covering the cable with bricks and back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
Earth work excavation of Trench in hard ground soil, laying of U.G cables from 70 to 300 Sqmm on sand cushion covering the cable with bricks and back filling of trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
Labour charges for run of U.G cables upto 50 sq.mm on wall with necessary fixing arrangments such as saddles, clamps etc., as directed by department including cost and conveyance of all materials etc., complete.
Labour charges for run of U.G cables from 70 to 300 Sqmm on wall with necessary fixing arrangments such as saddles, clamps etc., as directed by department including cost and conveyance of all materials etc., complete.
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI 3.5 core, 185 Sq.mm
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI 3.5 core, 25 Sq.mm
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI 3.5 core, 50 Sq.mm
Supply,transporatation & installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/Wall with suspenders etc., complete 150mm X 50mm X 1.6mm size
Supply,transporatation & installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/Wall with suspenders etc., complete 300mm X 50mm X 1.6mm size
Supply,transporatation & installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays with cover, including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/Wall with suspenders etc., complete 150mm X 50mm X 1.6mm size
Supply and Laying NP2 class RCC hume pipe with collars of following sizes for laying at the road crossings for the UG cables. 150 mm dia Hume pipe
Supply and fixing of 4Nos of 9 Ltrs capacity round bottom sand buckets along with bucket sand, Fire buckets with round bottom type enamel painted, white inside & red out side and letter FIRE inblack out side & Handle with mounting bracket.
Supply and fixing of Fire bucket stand fabricated by M.S. angles to install for Four numbers of buckets as per local fire officers standards
Supply and fixing of Co2 type Fire Extinguishers 4.5 Kg capacity confirming to IS 2878 made from ISI marked steam less cylinder confirming to IS:7285 & CE certified and fitted with ISI marked controlled valve confirming to IS:3224, high pressure 1 Mtr discharge hose & horn complete with initial gas charged with carrying handle with wheels and wall mounting bracket. Squeeze lever discharge, used un-used indicator, Aphoxy coated paint (Red) with 93% gloss with 2 years warranty Including transportation, all taxes and all labour charges etc complete. Makes : Cease Fire / Minimax.
Supply and fixing of ISI mark (IS:15683) Mono ammonium phosphate powder 90 (MAP) 6 Kg Fire extinguisher, stored pressure type, pressure gauge, gross wt. 9.4 kg, empty wt.3.4 kg, Discharge time minimum 13 sec, controllable discharge mechanism, range min. 4 mts applicable on classes A,B, C & electrically started fire, A rating -4 A, B rating -34 B, can construction: Deep drawn and Co2 mig welding, Valve construction: Forging & Machining, internal coating of can: Epoxy powder coating, External coating of Can:Epoxy polyster powder coating, sheet metal thickness:1.60mm, Helium leak detection tested with 5 years warranty Including transportation, all taxes and all labour charges etc complete. Makes : Cease Fire / Minimax.
Supply Installation Testing & commissioning of free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated/epoxy/PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure with required size of G.I. earth bus bar etc., complete. (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator). Incomer :- 630A 4 Pole MCCB adjustable, confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 50 KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-CVS/Legrand –(DP X3/DRX)/ Siemens- 3VL / Hager-h3/C&S -Winbreak/HPL-Techno -1 no Outgoing feeders:- Supply of 400A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-CVS/Legrand –(DP X3/DRX)/ Siemens- 3VL / Hager-h3/C&S -Winbreak/HPL-Techno -2 no Supply of 250A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-CVS/Legrand –(DP X3/DRX)/ Siemens- 3VL / Hager-h3/C&S -Winbreak/HPL-Techno -8 no Supply of 125A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-CVS/Legrand –(DP X3/DRX)/ Siemens- 3VL / Hager-h3/C&S -Winbreak/HPL-Techno -2 no Supply of 63A/60A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-CVS/Legrand –(DP X3/DRX)/ Siemens- 3VL / Hager-h3/C&S -Winbreak/HPL-Techno -2 no Metering:- Supply and Fixing of (0-500) V range Volt meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves/channel etc., as required. Make:Conzerve/Elmeasure/ Meco/ HPL/L&T/ Socomec -1 no Supply and Fixing of CT operated direct reading type Ammeter, above 500A, on existing panel , making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. Make: Conzerve/Elmeasure/Meco/HPL/ L&T/ Schneider/AE/ Socomec -1 no Supply and Fixing of Current Transformer, from 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracy with all necessary support in existing panel including connection etc. as required Make: Kappa/L&T/ Seimens/ C&S/ Schneider -3no Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp Red, Green & Yellow Colour with integral circuit, terminal block, including connection etc. as required Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp Blue Colour with integral circuit, terminal block, including connection etc. as required Supply and Fixing of selector switch for voltmeter (4 position) including making connection etc. as required. Make: L&T / C&S/ Salzer/HPL -1 no Supply and Fixing of CT linked selector switch of 10 A for Ampere meter (4 position) including making connection etc. as requiredMake: L&T/C&S/Salzer/ HPL-1no 10 kA - 6-32A range SP MCBs.Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx /L&T-AU/Indo Asian-Opti pro/ HPL (Techno) -6no Bus Bars:- Supply and fixing of Electrolytic grade aluminium bus bars by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves For Main Bus Bars vertical Phases & Neutral (80x10x1.8x2.7)/1000)x4 = 15.55 Kg + conecting Links for MCCBs = (50x10x0.6x2.7/1000)x4x2 + (40x8x0.6x2.7/1000)x4x8 + (25x8x0.6x2.7/1000)x4x2 = 6.48 Kg + 16.6 Kg + 0.65 Kg = 39.28 Kg For horizontal bus bars Phases & Neutral ((50x10x1.8x2.7)/1000) x 4 = 9.72 Kg For vertical section bus bars Phases & Neutral (50x10x1.8x2.7)/1000)x4 = 9.72 Kg Control wiring with suitable size of approved make FRLS PVC flexible copper wires, Earth Bus Bar, Door Loop earhtings, Ferrules, Feeder identifications, danger plate, door locks etc., labour charges for errection of switch gears, panels boards, with all other accessories including all labour charges etc with connections for finished item of work including transportation charges @ 5%
Supply Installation Testing & commissioning of free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated/epoxy/PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure, with proper ventilation arrangements for power capacitors with ventilating fans and louvres for natural cooling with required size of G.I. earth bus bar etc., complete. (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator). Incomer :- 250A TPN, MCCB of adjustable, confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: Hager / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL Outgoing feeders:- Supply of 63A/60A, 3 Pole, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted. Makes: Hager / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL Supply Installation Testing and commissioning of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector (PSD) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/ cables testing as required, Heavy duty Three phase 440 V , 50 Hz capacitor (Bank). Makes: L&T/Seimens/Epcos/ Schneider/ Havells Supply and Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current ,conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type ncluding making onnections, testing etc. as required. suitable for 10 KVAR capacity capacitor bank. Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells Supply and Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current ,conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type ncluding making onnections, testing etc. as required. suitable for 20 KVAR capacity capacitor bank. Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells Metering:- Supply and Fixing of (0-500) V range Volt meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves/channel etc., as required. Make:Conzerve/Elmeasure/ Meco/ HPL/L&T/ Socomec Supply and Fixing of CT operated direct reading type Ammeter, below 500A, on existing panel , making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. Make: Conzerve/Elmeasure/Meco/HPL/ L&T/ Schneider/AE/ Socomec Supply and Fixing of Current Transformer, from 200 / 5 to 500/5 Ratio , 15 VA , class 1 accuracy with all necessary support in existing panel including connection etc. as required Make: Kappa/L&T/ Seimens/ C&S/ Schneider Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp Red & Yellow Colour with integral circuit, terminal block, including connection etc. as required for capacitor ON and OFF + Supply indication Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp Blue Colour with integral circuit, terminal block, including connection etc. as required for supply indication Supply and Fixing of selector switch for voltmeter (4 position) including making connection etc. as required. Make: L&T / C&S/ Salzer/HPL Supply and Fixing of CT linked selector switch of 10 A for Ampere meter (4 position) including making connection etc. as requiredMake: L&T/C&S/Salzer/ HPL Supply and Fixing of Cam operated rotary switches on existing panel with 2 way and off position, one pole, 32A. (auto mannual selector switch for capacitors) Makes: L&T (SALZER)/ABB/ Schneider/ Seimens /C&S/HPL. Supply and Fixing of Non-Luminious type, push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required Make:Seimens/ ABB/ Schneider/ L&T/ C&S/HPL 10 kA - 6-32A range SP MCBs. Make: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ Crabtree-Xpro/L&T-AU Supply Installation Testing and commissioning of microprocessor based intelligent power factor correction relay having sensitivity up to 50 milli Amp secondary current and following way, self analysing auto c/k setting according to targeted power factor setting, the relay shall have minimum three digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release etc. as required, 6 to 14 stage - sensitivity upto 50 milli Amp. Makes: L&T/Seimens/Epcos /Schneider/ ABB/Neptune Labour charges etc complete with connections for finished item of work including all accessories, Auto / Manual Selector switches, auxilary contactors for auto manual operation,CTS and push buttons, indication lamps for on and off indication with all accessories etc. compele for finished item of work.
Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C.Chamber of 400m x 400m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)
Providing independent earthing for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 40mm dia G.I Pipe of 2.5 mtr length connected with reducer providing G.I funnel with wiremesh as per National Electric Code including C.C.Chamber of size 400m x 400m x 400mm covered with R.C.C. Slab filling with salt and charcoal giving earth connection from electrode with Copper strip of 25mm x 5mm x 200mm length to be bolted with nut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to Copper strip with all accessories and labour charges complete as per IS specification 732/1982 (Part II).
Providing independent earthling by excavating a trench to a depth of 2.5 M in all soils, as per size specified in the Data, using 100mm dia Heavy gauge Flange C.I ( Cast iron ) pipe of 2.5 Mtrs length with necessary accessories duly providing staggered holes including filling with equal proportion of Salt and Charcoal in layers and all labour charges etc., complete.
Supply and Run of 40mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete
Supply and Run of 25mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete.
Supply and Run of 40mm x 6mm copper strip including cost of all accessories and labour charges etc., complete.
Poviding transformer plinth 1.2 x 1.2 x 1.5 mtr in size with necessary excavation in ground at the bottom with 150mm thick 1:2:4 cement concrete raft at the bottom and top and 225mm thick wall constructed in stone masonry and remaking hallow portion shall be filled with stone chips duly plastered 20mm thick outsides including watering etc., complete
Supply and errecting fencing section having size 2.1 mt height from ground level and 1.2 mt width by using angle iron size 50mm x 50mm x 6 mm with 50 x 50 x 6mm 'T' Angle on middel, erected in C.C. foundation 15cm x 15cm x 40 cm deep. The section of the frame shall be fitted with hot dipped galvanised Iron chain link mesh of 8 gauge (4.0 mm) as per IS: 2721-1979 at a spacing of 2"x2" (50 mm x 50 mm) with flat iron support of size 25 x 6 mm on top, bottom and midle and sides and including all accessories and duly painted with one coat of red oxide and 2 coats of aluminium paint and all labour charges etc. complete.
Supply and fixing of gate fixing frame with size 2.1M x 1.25M width fabricated with MS Angle 40x40x6mm fencing frame and the gate of size 1.8M x 1.25M with Angle 35x35x5mm four sides and 40x40x6mm 'T' Angle in middle & M.S weld mesh 2"x2" including painting.
Supply, Transportation of 75 x 40 mm ISMC 100 channel iron with two coats of aluminium and one coat of red oxide paint complete
Supply, transportation and spreading the 40mm size HBG metal in two layers of about 100mm thick in and around the sub-station yard.
stage.html
html • 0.01 MB
aoc.html
html • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.01 MB
TD 9-2 Dr AR Homeo MC RJY 2025-26.docx
TENDER_DOCUMENT • 0.73 MB
BOQ for upload Dr AR Homeo.xls
TENDER_DOCUMENT • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .