Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance WARD NO 12 TAMLUK PARBATIPUR TAMLUK PURBAMIDNAPUR 721636 | TAMLUK | PURBA MEDINIPUR | WEST BENGAL | 721636 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.6 L
EMD Value
₹7,218
Closing Date
22 Oct 2024, 2:00 pmClosed
The Divisional Manager, Tamluk Divisional Office
Office of the Divisional Manager, Tamluk, Bijali Bhavan(2nd Floor), Daharpur,Tamluk, Purba Medinipur
Work schedule for installation of 25 KVA DTR on 9mt DP struture wilth drawal of 185 mtr HTOH line and 374 mtr UG cable for PHE connection at Danipur under Nandakumar CCC under Tamluk Division
2024_WBSED_760779_1
DMTD/E-TENDER/PHE_DANIPUR /CABLE LAYING/2024-25/06 DT-01.10.2024
Open Tender
Miscellaneous Services
Item Rate
60 days
Danipur, Tamluk
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,218
Office of the Divisional Manager, Tamluk, Bijali B
3 Jan 2025
1 Oct 2024
25 Oct 2024
1 Oct 2024
22 Oct 2024
4 Oct 2024
4 Oct 2024
Amount
GIS SURVEY
ERECTION OF 9 MTRS SINGLE POLE COMPLETE WITH ALL FITTINGS i.e, V- BRACKET, TOP ADAPTOR ETC. AND FOUNDATION BUT WITHOUT ANY INSULATOR FOR HV OH LINE UPTO 33 KV WITH PAINTING
ERECTION OF 9 MTRS DOUBLE POLE STRUCTURE COMPLETE WITH ALL FITTINGS AND FOUNDATION BUT WITHOUT ANY INSULATOR FOR HV OH LINE UPTO 33 KV WITH PAINTING
ERECTION OF 8 MTRS SINGLE POLE COMPLETE WITH ALL FITTINGS i.e, V- BRACKET, TOP ADAPTOR ETC. AND FOUNDATION BUT WITHOUT ANY INSULATOR FOR HV OH LINE UPTO 33 KV WITH PAINTING
ERECTION OF 9 MTRS SUB-STATION STRUCTURE COMPLETE WITH ALL FITTINGS ie. FITTINGS FOR ISOLATOR. FUSE UNIT, TRANSFORMER, KIOSK, MS HOOD, TOP CHANNELON ETC. AND FOUNDATION BUT WITHOUT INSULATOR WITH PAINTING
EXTENSION OF 9 MTRS SINGLE POLE COMPLETE WITH ALL FITTINGS UPTO 3 MTR. LENGTH BUT WITHOUT INSULATOR FOR HV OH LINE UPTO 33 KV WITH PAINTING
EARTHING COMPLETE WITH DRIVING OF EARTH SPIKE & CONNECTION OF EARTH ELECTRODE WITH NON CURRENT CARRIN METALIC PARTS OF SUPPORTS. STAY WIRE, CRADLE GUARDS, L.A. ETC.
STAY SET COMPLETE WITH ALL FITTINGS, GUY INSULATOR BINDING ETC.(HT STAY SET (1830X20 mini))
STAY SET COMPLETE WITH ALL FITTINGS, GUY INSULATOR BINDING ETC.(LT STAY SET (1630 X 10 mm))
FIXING OF 11 KV PIN INSULATOR WITH PIN
FIXING OF 11 KV DISC INSULATOR WITH STRAIN HARDWARE
FIXING OFLT SHACKLE INSULATOR WITH 1 NO. G.I NUTS & BOLTS
ERECTION OF 25 KVA 11/0.43 KV DISTRIBUTION TRANSFORMER COMPLETE WITH ALL FITTINGS (O/D TYPE)
FIXING OF 11 KV T.P.G.O. ISOLATOR ON SUB-STATION STRUCTURE WITH PROPER ADJUSTMENT
FIXING OF 11 KV LIGHTNING ARRESTER ON STRUCTURE (1 SET OF 3 L.A.S)
NEUTRAL EARTHING WITH SUPPLY OF NECESSARY MATERIALS AS PER WBSEDCL NORMS
FIXING OF KIOSK AND MAIN SWITCH AND COMPLETE CONNECTION WITH PVC CABLE FOR DOUBLE CIRCKET
FIXING OF SOLID TEE OFF BRACKET WITHOUT INSULATOR SINGLE POLE
FIXING OF SOLID TEE OFF BRACKET WITHOUT INSULATOR DOUBLE POLE
FABRICATION & FIXING OF CRADLE GUARD BRACKET FOR SINGLE POLE
LEAD WIRE (a) UPTO 30 MTRS.(2 WIRE)
DO (b) ABOVE 30 MTR. BUT UPTO 60 MTR.(2 WIRE)
MAKING & FIXING OF CROSS LESSING WIRE
ERECTION OF 3 WIRE 50 Sq. mm. ACSR 'RABIT' OR EQI. SIZE OF AAAC CONDUCTOR INCLUDING LAYING, HOISTING, STRINGING, JOINTING, SAGGING, TENSIONING & ROUTE CLEARANCE
3 PHASE SERVICE CONNECTION WITH SUPPLY OF ALL MATERIALS, 16 SQMM PVC CABLE 1.1 KV GRADE, EARTHING COMPLETE ETC.
GIS Survey of H.T (11KV) cable route as per instruction of site Engineer and submission of route survey drawing (in two copies ) inscribing different land marks.
Excavation of soil by cutting of Metalled Road/Cement Concrete/Brick Soling etc & re- instatement of the same as per instruction of Site Engineer
G.I Pipe 100mm dia.(Medium)
SUPPLYKILIN BERNT PROPER SIZE 1ST CLASS BRICK
LAYING OF BRICKS
Laying & dressing of following 11 KV 185 SQMM XLPE cable in the excavated cable trenches as per drawing no.PLN(D)/SS/104, dt. 05.05.2015 and instruction of the Site Engineer.
Supply & Erection of Cast Iron Cable Marker on concrete foundation blocks for straight run, road crossing, joint location etc as per drawing no..PLN(D)/SS/107 or 108, dt. 05.05.2015 & specification & direction of Site Engineer.
Making protective duct for cable joint complete as per WBSEDCLs approved drawing (Ref. Drg. no.PLN(D)/SS/106, dt. 05.05.2015)
Laying of HDPE pipe as per Jack push method as per instruction of Site Engineer and as per site condition for laying of U.G cable including supply of With 110mm diam. HDPE Pipe, PE-80 , PN-6 as per IS: 4984-1995
ACAM CONSTRUCTION (BID ID -5710842)
MAHAKALI ENGINEERING WORKS (BID ID -5711040)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .