Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹10.2 L
EMD Value
₹20,400
Closing Date
9 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE PHED dn Rajsamand
EE PHED dn Rajsamand
CONTIGENCY WORK REPLACMENT OF PUMP MCHINARY BLOCK-RAJSAMAND DISTRICT RAJSAMAND
2026_PHCJA_606715_1
EE NIT 100/2026-27
Open Tender
Civil Works - Water Works
Percentage
30 days
Rajsamand
As per TD
5 documents required · 5 mandatory
₹1,000
EE PHED dn Rajsamand
₹20,400
Yes
27 Nov 2026
27 Nov 2026
10 Dec 2026
27 Nov 2026
9 Dec 2026
27 Nov 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
Rates are exclusive of GST. | - | - | - | - |
| 2 | 5.5 KW (7.5 HP) | 2 | EACH | 45,583.9 | ₹91,167.8 |
| 3 | 7.5 KW (10 HP) | 1 | EACH | 51,389.83 | ₹51,389.83 |
| 5 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
Rates are exclusive of GST. | - | - | - | - |
| 6 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. | 11 | KW | 8,159.32 | ₹89,752.52 |
| 7 | 7.5 KW (10 HP) & head above 120 mtr. | 7.5 | KW | 7,050.85 | ₹52,881.38 |
| 9 | 9.3 KW (12.5 HP) & head above 120 mtr. | 18.6 | KW | 6,400 | ₹1,19,040 |
| 10 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
Rates are exclusive of GST. | - | - | - | - |
| 11 | Above 5 HP and up to 10 HP | 1 | Each | 20,570.34 | ₹20,570.34 |
| 12 | Above 10 HP and up to 15 HP | 1 | Each | 23,583.9 | ₹23,583.9 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_1076119.xls
BOQ • 0.32 MB
TD100.pdf
Tender Documents • 30.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .