Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC AOC | |
| 2 | L2₹12.5 L+₹2.3 L (22.4%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹12.9 L+₹2.7 L (26.0%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | vinayandsons L2 | Shri Electrical Enterprises L1 | BHAGYALAXMI ENGINEERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified.
Note:- The damaged surfaces to be made good with plastering & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible. | 459 | Per Point | 100 ₹45,900 | 15 ₹6,885 Lowest | 40 ₹18,360 |
| 2.00 | Taking down old unserviceable/worn out sub main wiring/service wire of any type and size complete all as specified. | 555 | RM | 25 ₹13,875 | 5 ₹2,775 Lowest | 25 ₹13,875 |
| 3.00 | Taking down Main switches/DBs/Metal clade socket of any make and type including teakwood board, MCBs/MCCBs etc complete and making good the disturbed surfaces including colour wash complete all as specified. | 24 | Each | 50 ₹1,200 | 30 ₹720 Lowest | 60 ₹1,440 |
| 4.00 | M&L for point wiring of any length using approved colour coding as per IS complete with 1.5 sqmm single core multistranded copper conductor PVC(FRLS) insulated and unsheathed cable in and including PVC casing caping fixed on wall,surface,ceiling etc including 3mm thick, laminated Hylen sheet (white colour) for mounting switches, socket, regulator etc on including sunken type pvc terminal box screw with washer for fixing with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly complete all as specified for the following :-
One light / Celling fan /Exhaust fan/Air circulator fan/ bell/buzzar point controlled by one, one-way switch, SP, 6 Amps. all as specified. | 95 | Per Point | 550 ₹52,250 | 470 ₹44,650 | 450 ₹42,750 Lowest |
| 5.00 | All item as per Ser No 4.00 above but one 3 pin 5 amps socket outlet point on same board complete all as specified. | 30 | Per Point | 100 ₹3,000 Lowest | 150 ₹4,500 | 240 ₹7,200 |
| 6.00 | All item as per Ser No 4.00 above but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified. | 55 | Per Point | 550 ₹30,250 | 500 ₹27,500 Lowest | 500 ₹27,500 Lowest |
| 7.00 | All item as per Ser No 4.00 above but one light point controlled by two 2-way switches complete all as specified. | 2 | Per Point | 750 ₹1,500 | 525 ₹1,050 Lowest | 810 ₹1,620 |
| 8.00 | All item as per Ser No 4.00 above but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified. | 40 | Per Point | 750 ₹30,000 Lowest | 750 ₹30,000 Lowest | 830 ₹33,200 |
| 9.00 | M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC rigid conduits heavy duty ISI marked concealed in wall/floor/roof including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-Note- (i) Cutting in chases and pointing in will be done by contractor without any cost. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost.
One light / Celling fan /Exhaust fan/Air circulator fan/ bell/buzzar point controlled by one,One-way switch complete all as specified. | 40 | Per Point | 700 ₹28,000 | 670 ₹26,800 | 620 ₹24,800 Lowest |
| 10.00 | All item as per Ser No 9.00 above but one 5 pin 5Amp Socket outlet point on same board with other switches including earth wire. | 10 | Per Point | 100 ₹1,000 Lowest | 150 ₹1,500 | 300 ₹3,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Aug 2025, 6:00 pmClosed
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION OF HANGER AND ITS CONNECTED ITEMS FOR TECHNICAL AREA AT NAGTALAO UNDER GE BANAR
2025_MES_713088_2
8825/34/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹30,000
Yes
8 Oct 2025
23 Jul 2025
20 Aug 2025
23 Jul 2025
13 Aug 2025
30 Jul 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified. Note:- The damaged surfaces to be made good with plastering & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible.
Taking down old unserviceable/worn out sub main wiring/service wire of any type and size complete all as specified.
Taking down Main switches/DBs/Metal clade socket of any make and type including teakwood board, MCBs/MCCBs etc complete and making good the disturbed surfaces including colour wash complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS complete with 1.5 sqmm single core multistranded copper conductor PVC(FRLS) insulated and unsheathed cable in and including PVC casing caping fixed on wall,surface,ceiling etc including 3mm thick, laminated Hylen sheet (white colour) for mounting switches, socket, regulator etc on including sunken type pvc terminal box screw with washer for fixing with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly complete all as specified for the following :- One light / Celling fan /Exhaust fan/Air circulator fan/ bell/buzzar point controlled by one, one-way switch, SP, 6 Amps. all as specified.
All item as per Ser No 4.00 above but one 3 pin 5 amps socket outlet point on same board complete all as specified.
All item as per Ser No 4.00 above but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified.
All item as per Ser No 4.00 above but one light point controlled by two 2-way switches complete all as specified.
All item as per Ser No 4.00 above but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC rigid conduits heavy duty ISI marked concealed in wall/floor/roof including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-Note- (i) Cutting in chases and pointing in will be done by contractor without any cost. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost. One light / Celling fan /Exhaust fan/Air circulator fan/ bell/buzzar point controlled by one,One-way switch complete all as specified.
All item as per Ser No 9.00 above but one 5 pin 5Amp Socket outlet point on same board with other switches including earth wire.
All item as per Ser No 9.00 above but one 5 pin 5Amp Socket outlet point on independent board complete all as specified.
All item as per Ser No 9.00 above but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified.
M&L for point wiring complete with 1.5sqmm single core multistranded copper conductor PVC (FRLS) insulated and unsheathed cable in existing PVC conduit or casing caping fixed on wall surface, ceiling etc including 3mm thick laminated hylen sheet for mounting switches sockets regulator etc on existing sunk cast iron terminal boxes, screw with washer for fixing with 1.5 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable as earth continiuty conductor to common earth and earth dolly for the following. One light / Celling fan /Exhaust fan/Air circulator fan/ bell/buzzar point controlled by one, One-way switch complete all as specified. Note: The junction box should be concealed in wall and making good to match the existing surface.
All item as per Ser No 13.00 above but one 5 pin 5Amp Socket outlet point on same board.
All item as per Ser No 13.00 above but one 5 pin 5Amp Socket outlet point on independent board complete all as specified.
All item as per Ser No 13.00 above but one light point controlled by two 2-way switches complete all as specified.
All item as per Ser No 13.00 above but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified.
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including In Stove enamelled steel Conduit (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specified for One light/ celling fan/ exhaust fan/Air circulator fan point controlled by one switch.
Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In stove enamelled Steel conduit with all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mounting switches socket for 3 pin 15 amp independent board complete all as specified.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps 230 Volts complete all as specified.
Supply and fix switch piano, flush type, single pole, one way 15 Amps 230 Volts complete all as specified.
Supply and fix socket outlet 2-in-1, 3 pin, 5 Amps, flush type with shutter, complete all as specified.
Supply and fix of socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters complete all as specified.
Supply and fix switch socket combination 2-in-1, 3 pin, 5 Amps, flush type with shutter complete all as specified.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters complete all as specified.
Supply and fix electronic regulator, 100W, 250V flush type on the exiting phenolic laminated sheet etc complete all as specified.
Supply and fix of ceiling rose, surface bakelite, three terminals complete all as specified.
Supply and fix Lamp Holder PVC/polycarbonate type with back plate ISI Marked for fixing bulbs complete all as specified for batten fitting
Supply and fix Pin Top 15 Amp complete all as specified.
Supply and fix buzzer, ding dong AC 230 Volt, Single pole complete all as specified.
Supply and fix Bell multi Musical type AC 230 Volt, Single pole complete all as specified.
Supply and fix Bell push, AC 230 Volt, Single pole complete all as specified.
Supply and fix in replacements SPN DB's 12 way, 240 V, double door100 Amps rated bus bar, complete all as specified for following:-
All as per item No 33.00 above but 8 way
All as per item No 33.00 above but 4 way
Supply and fix in replacement 4 way TPN DB, 415 V, double door 200 amps rated bus bar, including making good disturbed surfaces of walls including plaster cutting of wall etc complete all as specified.
Supply and fix in replacement 4 way VTPN DB, 415 V, double door 200 amps rated bus bar, including 100 Amps 4 pole, 16 KA MCCB, making good disturbed surfaces of walls including plaster cutting of wall etc complete all as specified.
S&F in replacement MCCB 4 Pole 125 Amp 16KA complete all as specified.
S&F in replacement MCCB 4 Pole 100 Amp 16KA complete all as specified.
Supply and fix in replacement MCB SPN 32/40 Amps 240 volts complete all as specified.
Supply and fix in replacement MCB SP 6 Amps to 32 Amps 230 volt complete all as specified.
Supply and fix in replacement MCB TP 25 Amps to 63 Amps 415 volt complete all as specified.
Supply and fix in replacement MCB TPN 16 Amps to 32 Amps 415 volt complete all as specified.
Supply and fix in replacement MCB TPN 40 Amps to 100 Amps 415 volt complete all as specified.
M & L for Sub main wiring with Two runs of 6.0 Sqmm size main cable and one run of 6.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi stranded copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 6 Sqmm conductor and one run of PVC conduit shall be measured as one unit length.)
All item as per Ser No 45.00 but 02 runs 4 sqmm conductor cable and 01 run of 4 sqmm as earth continuity conductor.
All item as per Ser No 45.00 but 02 runs 2.5 sqmm conductor cable and 01 run of 2.5 sqmm as earth continuity conductor.
M&L for Sub main wiring with Four runs of 6.0 Sqmm size main cable and one run of 6.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi stranded copper conductors, 1100 volts grade, all drawn through and including suitable size rigid PVC conduit pipe & fittings/ accessories all fixed to the surface/recessed of wall/ceiling complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 5 runs of 6 Sqmm conductor and one run of PVC conduit shall be measured as one unit length.)
M&L for Sub main wiring with Four runs of 10.0 Sqmm size main cable and one run of 10.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi stranded copper conductors, 1100 volts grade,all drawn through and including suitable size rigid PVC conduit pipe & fittings/ accessories all fixed to the surface/recessed of wall/ceiling complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 5 runs of 10 Sqmm conductor and one run of PVC conduit shall be measured as one unit length.)
Supply and fix in replacement Modular metal flush box with white cover plate with frame of 03 Module, for mounting, switches, sockets, fan regulator, etc. 3 module Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items.
All as per Ser item No 50.00 but 6 module
All as per Ser item No 50.00 but 8 module but white cover plate only
All as per Ser item No 50.00 but 12 module but white cover plate only
Supply and fix in replacement switch modular 5/6 Amp single pole, one way 1 module complete all as specified.
Supply and fix in replacement switch modular 15/16 Amp single pole, one way 1 module complete all as specified.
Supply and fix in replacement Moduler switch 2 way 5/6 Amp 1 module complete all as specified.
Supply and fix in replacement Bell push modular 6 Amp single pole, one way 1 module complete all as specified.
Supply and fix in replacement Fan Regulator modular 120W single pole,one way 2 module complete all as specified.
Supply and fix in replacement Socket modular 5/6 Amp single pole, 2/3 pin 2 module complete all as specified.
Supply and fix in replacement Socket modular 6/16 Amp single pole, 2/3 pin 2 module complete all as specified.
Supply and fix in replacement Switch socket outlet modular multipurpose 3 Pin 6 Amp flush type controlled by one switch complete all as specified.
Supply and fix in replacement Switch socket outlet modular multipurpose 3 Pin 16 Amp and one pin 6 Amp controlled by one switch complete all as specified.
S&F in replacements Metal Clad Plug and socket with box 20 Amp with MCB single pole complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm as per specification complete all as specified.
Supply and fixing in replacement Metal plug and socket boths 20A 3 phase 3 pin as per IS 8804 suitable for existing metal clad box as per specification complete all as specified.
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep complete all as specified.
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175mmx100mmx50mm deep complete all as specified.
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mmx200mmx50mm deep complete all as specified.
Supply and fix in replacement PVC Junction box with cover 25mm as per site requirement complete all as specified.
Supply and fix in replacement PVC TV Socket 5 Amps 230 Volts complete all as specified.
Supply and fix in replacement PVC Telephone Socket 5 Amps 230 Volts complete all as specified.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified.
S&F in replacement of surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt, fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable which shall be passed through PVC flexible conduit complete all as specified.
S&F in replacement of surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x10 Watt, fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable which shall be passed through PVC flexible conduit complete all as specified.
Supply and fix replacement of LED recessed Round type down light fiiting 15W, 230V 50Hz ultra sleek low height false ceilingin round shape luminaire with high power LED long life aesthetically designed with symmetrical light distribution with IP-65 230 V complete with driver all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all acessories complete all as specified.
S&F in replacement of building security light LED fitting 35/45 watt 230V AC outdoor type with high pressure die cast housing and heat resistant complete with driver, epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including lamp LED 35/45 watt,IP-65/66 fixed / connect properly at directed location on building complete all as specified.
S&F in replacement 63 Amps,5 Pin, 3 Phase with (3P+N+E) Industrial DB Plug & socket Comied in metal enclosure singal door with MCB TP completed with on Wall with complete all as specified.
S&F in replacement 32 Amps,5 Pin, 3 Phase with (3P+N+E) Industrial DB Plug & socket Comied in metal enclosure singal door with MCB TP completed with on Wall with complete all as specified.
Supply,fixing and testing in replacement of LED 30/45W driver with surge protection complete connection to LED street light fitting with suitable wire complete all as specified.
Dismentalling old rusted earthing and M & L for building earthing in replacements complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron wire 4mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in hard/dence soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 complete all as specified.
S&F in replacement of Plastic laminated sheet 4" X 4" , 3mm thick fixed with screws complete all as specified.
S&F in replacement of Plastic laminated sheet 7" X 4" , 3mm thick fixed with screws complete all as specified.
S&F in replacement of Plastic laminated sheet 11" X 7" , 3mm thick fixed with screws complete all as specified.
S&F in replacement Fan capacitor 2.5 MFD complete all as specified.
Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 2.5 Sqmm and one run of size 2.5 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling complete all as specified. Note :- 3 runs of 2.5 Sqmm conductor and one run of steel conduit shall be measured as one unit length.
Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 6 Sqmm and one run of size 6 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling complete all as specified. Note :- 3 runs of 6 Sqmm conductor and one run of steel conduit shall be measured as one unit length.
Supply and fix in replacement flameproof switch socket and plug(2P+E) 16Amp 250V complete all as specified.
Supply and fix replacement flameproof switch socket and plug(3P+E) 16Amp 415V complete all as specified.
Supply and fix in replacement LED light fiiting 1x16 watt flame proof ,CMRI certified recommended for gas/vapor group of IIA & IIIB Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver,holder,connector etc,complete with all three core flexibble copper conductor cable with suitable size complete all as specified.
suply and fix in replacement flameproof rotary switch with cable terminal box in LM6 10 Amp single pole on-off complete all as specified.
suply and fix in replacement flameproof rotary switch with cable terminal box in LM6 16 Amp single pole on-off complete all as specified.
suply and fix in replacement flameproof Junction box 100 dia upto 4 way in LM6 complete all as specified.
vinayandsons (BID ID -3381680)
BHAGYALAXMI ENGINEERS (BID ID -3385112)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .