Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-Finance TELIWALA PADLI GUJJAR MILAP NAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-Finance L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | M/S AARIF CONTRACTOR L1 |
|---|---|---|---|---|
| 1.00 | Supply and installation of 12 mm thick Flux standing seam polycarbonate panel system of DPI daylighting or equivalent, supply and installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co-extruded UV protected multicell panels incorporated into a complete system. Co extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm min width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panles with alll fixing accessories to ensure best performance for wind uplift vibration, oil canning and visual apprearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid separately) with 2 numbers self drilling screws and trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull out load of min 7000N tested as per ISO 6892-1998 and IS 1608-2005 as per design requirement. Panels must satisfy dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min of 500 Hours as per ASTM G 155. 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2; 2018. Panel shall be with additional end cap/ aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel / MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the Engineer In-charge. | 630 | sqm | 3,650 ₹22,99,500 Lowest |
| 2.00Dismantling roofing including ridges, hips, valleys and gutters, etc. and stacking the material within 50 meters lead of: | ||||
| 3.00 | GS Sheet | 630 | sqm | 100 ₹63,000 Lowest |
| 4.00 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 980 | kg | 10 ₹9,800 Lowest |
| 5.00 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. | 194 | sqm | 70 ₹13,580 Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
5 Jan 2026, 1:00 pmClosed
Institute engineer
IWD IITR
Replacement of Polycarbonate sheet at Kasturba Bhawan in Zone C at IIT Roorkee
2025_IITR_889837_1
IWD/IE/2025-26/E Tender/C-18 Dated December 12 , 2025
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
Registrar
₹50,000
18 Feb 2026
15 Dec 2025
6 Jan 2026
15 Dec 2025
5 Jan 2026
22 Dec 2025
Supply and installation of 12 mm thick Flux standing seam polycarbonate panel system of DPI daylighting or equivalent, supply and installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co-extruded UV protected multicell panels incorporated into a complete system. Co extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm min width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panles with alll fixing accessories to ensure best performance for wind uplift vibration, oil canning and visual apprearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid separately) with 2 numbers self drilling screws and trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull out load of min 7000N tested as per ISO 6892-1998 and IS 1608-2005 as per design requirement. Panels must satisfy dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min of 500 Hours as per ASTM G 155. 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2; 2018. Panel shall be with additional end cap/ aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel / MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the Engineer In-charge.
Dismantling roofing including ridges, hips, valleys and gutters, etc. and stacking the material within 50 meters lead of:
GS Sheet
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
Tender_doc.pdf
Tender Documents • 3.46 MB
BOQ_935280.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .