Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC N A | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹49.2 L+₹1.2 L (2.42%)Rejected-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹43.8 L
EMD Value
₹87,500
Closing Date
17 Apr 2023, 6:00 pmClosed
Santosh Kumar Rai IDSE SE CWE NB
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
DESIGN AND CONSTRUCTION OF DEFICIENT TRAINING SHED NEAR GUN GRID AT INS DRONACHARYA
2023_MES_585204_1
81084
Open Tender
Civil Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹87,500
Yes
2 May 2023
10 Mar 2023
22 Apr 2023
10 Mar 2023
17 Apr 2023
31 Mar 2023
Amount
Planning, Design, supply, fabrication and Construction of training shed of size 20m x 10m x 4m(height at centre with slope towards sides) in Pre-stressed and Pre-Cast RCC Technology of permanent specification complete all as specifed and as directed up to the satisfaction of Engineer-in-Charge including preparation of Detailed Engineering for development of Architectural, Construction and Structural Drawings etc, structure analysis & design Planning, designing & execution of services i.e Topography survey, Soil Investigation , Site clearance and Site Development , internal water supply , Internal electrification work and other B/R and E/M services complete. Notes :- (i) The quoted rate includes preparation of conceptual plan/architectural/structural design and drawings and vetting through IIT College and obtaining prior approval from Accepting Officer before execution. (ii) Any other work/ services/utility, which is not included above but essential for the completion of the project,the same shall be deemed to be included in this item Lump sum price worked out by the Contractor. Obtaining all statutory clearances and certifications are included in the scope of work.
Material and labour for moorum/red bajri filling in floor or pavings laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specifed and as directed up to the satisfaction of Engineer-in-Charge.
Material and Labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed FRLSH copper conductor cable ISI marked, with and including continuos earth wire of size 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed FRLSH copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia of medium grade complete with ISI marked and including all PVC conduit accessories fixed on wall or roof and making good to the disturbed surfaces for one fan/light point controlled by one 6 Amps switch complete all as specifed and as directed up to the satisfaction of Engineer-in-Charge.
All as per item No. 3 here in before but one 3 pin 5 amps socket outlets on independent board with 1.5 sqmm size cable.
All as per item No. 3 here in before but one 3 pin 5 amps socket outlets on same board with other switches with 1.5 sqmm size cable.
All as per item No. 3 here in before but one 3 pin 15 amps socket outlets on independent board with 2.5 sqmm size cable.
Supply and Fix switch piano flush button type 5 amp single pole one way complete all as specified and directed.
Supply and Fix switch socket combination outlet multipurpose 2 in 1, 5 pin 6 Amps and 2 pin 6 Amps, flush type complete all as specified and directed.
Supply and Fix switch socket combination outlet multipurpose 6 Amps and 16 Amps, flush type complete all as specified and directed.
Supply and Fix socket outlet multipurpose 2 in 1, 5 pin 5 Amps and 2 pin 5 Amps complete all as specified and directed.
Supply and Fix ceiling rose two or three terminals PVC polycarbonate isolated body including connecting up complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix stepped type electronic fan regulator flush type complete all as specified and directed.
Supply and fix surface mounted LED integrated batten, 20/22 Watt with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure DB SPN AC 240 V, 8 way with 200 Amp rated bus bar and double door with necessary fixing arrangements complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP, AC, 6 to 32 AMP 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 40 AMP 415V breaking capacity 10KA, 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Material and labour for Submain wiring in surface/recessed with 2.5 Sqmm two single core using multistranded copper conductor FRLS insulated unsheathed 1100 volt with and incl one run of 2.5 Sqmm insulated unsheathed FRLS insulated multistranderd single core copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit medium grade ISI marked with accessories complete all as specified and as directed by the Engineer-in-Charge. Note: 2 runs of 2.5 Sqmm , one run of 2.5 Sqmm and one run of PVC conduit shall be measured as one run only.
Supply and fixing of LED building security light fitting 35 watts protection comprises of a pressure die cast aluminium housing, polycarbonate cover, high power LED with lenses, 10 KV built-in-surge protection, electronic driver, etc and all accesories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 sqmm, 3 core as required for connections and 32 mm bore light grade GI tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in 'L' shape and fixed to wall by means flat iron clamps, nuts, boltss and washers etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) including electric connection complete all as specified and as directed by Engineer in Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 metres below normal ground level with top edge of the earth plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main switch board/main DBs including excavation, earth work in soft/loose soil and removal upto 50m, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20mm bore for watering, GI sheet funnel with wire mesh, PCC chamber pit in PCC 1:3:6 type C-1, precast RCC 1:2:4, type B1 cover slab of 40mm thick reinforced with 6 mm dia TMT bars @ 75mm C/C on both sides and 12mm dia MS handle, angle iron 40 mmx 40 mm x 3 mm frame for pit cover complete all as specified and shown in Electric plate No.03 of SSR Part-I, connecting to earthing test point all as specified and directed including testing on completion.
Supply and lay XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having 25 Sqmm 2 core section area, 1100 volt grade, heavy grade conforming to IS:7098 (Part 1) laid in trenches/ducts or pasing through pipe or fixing on poles etc, complete all as specified and as directed by Engineer in Charge. Note: Necessary earth work, sand cushioning, cable protection cover, GI pipe etc, will be measured and paid eparately under relevent items.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq. m on plan and n exc 1.5 m in depth and getting out soft/loose soil etc. complete all as specified and as directed by Engineer in Charge.
Supply, fill and spread locally available dry sand in trenches compacting for sand cushioning and covering of UG cable complete all as specified and directed. Note: Only Punned thickness of 18 cm shall be measured for payment.
Supply and lay burnt bricks, sub class 'B' brick standard size for common burnt clay building bricks, designation 75 for cable protection, laid length of brick perpendicular to length of cable complete all as specifed and as directed up to the satisfaction of Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm etc. complete all as specified and as directed by Engineer in Charge.
Removing excavated material to a distancen exc 50 m and depositing where directed at level n exc 1.5 m above the starting point etc. complete all as specified and as directed by Engineer in Charge.
Material and labour for galvanised steel tubing 50 mm bore, light grade with bend laid in trenches or under roads/flooring/culverts and or fixing to electric poles with suitable size mild steel flat iron clamps, bolts, nuts, washers etc, complete all as specified and as directed by Engineer in Charge.
Kakolil Trade Agencies
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .