| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Being the First Lowest | |
| 2 | L2₹17.7 L+₹1.1 L (6.89%)Rejected-Finance 114 RAJEEV GANDHI NAGAR KOTA RAJ | KOTA | KOTA | RAJASTHAN | 324005 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹17.7 L+₹1.2 L (7.29%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹17.8 L+₹1.3 L (7.81%)Rejected-Finance 43 MANAK BHAVAN FIRST FLOOR GUMANPURA KOTA 324 007 RAJASTHAN | KOTA | KOTA | RAJASTHAN | 324007 | L4 | Rejected-Finance Other Than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Kota
Dadwara Complex, Military Station Kota - 324002
REPAIR/ MAINTENANCE OF LT ELECTRIFICATION ALONGWITH CONNECTED ITEMS IN SOUTHERN SECTOR AT MIL STN KOTA
2022_MES_550949_1
8666/E8
Open Tender
Electrical and Maintenance Works
Item Rate
275 days
KOTA
Contractor shall be enlisted with MES in Class E and above and category b(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Workload Return (WLR) or any other report circulated by competent engineer au
8 documents required · 8 mandatory
₹500
GE KOTA
₹40,000
Yes
26 Nov 2022
9 Sept 2022
8 Oct 2022
9 Sept 2022
6 Oct 2022
24 Sept 2022
9 Sept 2022 - 19 Sept 2022
60 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Add to item no 01.00 (here-in-before) for each additional 1.5m or part thereof in depth beyond the first 1.5m depth complete all as specified & directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removing excavated material (soil) n exc. 50m distance and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L dry clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint & including dismantling of old unserviceable cross arms of MS channel or angle sections etc complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, white , borwn or green insulator, including one galvanised mild steel spindle, two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia & including dismantling of old unserviceable insulator, complete all as specified and directed.
M&L for insulator disc type porcelain, vitreous, 100 mm high and 115 mm dia ball and socket type, white, brown or green, two in series assembly for tension with tension clamps for conductor, working pressure 1100 volts & including dismantling of old unserviceable insulator, complete all as specified and directed.
S&F in renewal of stay assembly complete comprising of galvlanised steel stay wire stranded 7/4 mm galvanised steel stay bow 400x20mm stay rod, 1800 mm long, 20 mm dia with nuts, bolts and washers, steel plate 300x300x6.0 mm two Nos thimble, including loop type insulator size 90 x 140 mm clearance hole of 20 mm dia including necessary excavation, earth work in any type of soil, PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation, disposal of surplus soil upto a distance of 50 m and fixed to stay clamp, complete all as specified in electrical plate No 1 of MES SSR part I and directed. (Stay clamps shall be measured separately in MS Work).
Supply, straining, streching and fixing ACSR conductor on HT/LT poles or on existing poles including binding and jointing to conductor/ insulator with and including suitable size of copper binding wire or aluminium tape and testing & including dismantling of old unserviceable ACSR conductors from the poles, complete all as specified and directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 32x6 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed.complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth lead strip upto 7.5 m.
S&F in renewal of earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
S&F in renewal of galvanised iron earth strip of size 25x4 mm, fixed to wall or pole, complete all as specified and directed.
S&F in renewal of 50 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
S&F in renewal of 80 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
S&F in renewal of 100 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade (ISI marked), laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 19.01 to 19.09 :- (i) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ. (ii) Rate deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. Cross Sectional area of cable 16 Sq mm 4 core
Cross Sectional area of cable 25 Sq mm 4 core
Cross Sectional area of cable 50 Sq mm 3.5 core
Cross Sectional area of cable 70 Sq mm 3.5 core
Cross Sectional area of cable 95 Sq mm 3.5 core
Cross Sectional area of cable 120 Sq mm 3.5 core
Cross Sectional area of cable 150 Sq mm 3.5 core
Cross Sectional area of cable 185 Sq mm 3.5 core
Cross Sectional area of cable 10 Sq mm 2 core
Taking down old unserviceable PCC pole/existing pole and Supply, transporting, erection and fixing steel tubular swaged pole, 9.00 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete, complete all as specified and directed.
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 9 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting 100 mm wide reflective red strickers in 3 lines around the pole, complete all as specified and directed.
S&F PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 4 line, complete all as specified and directed.
S&F PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 3 line, complete all as specified and directed.
M&L for cutting of bushes including trimming of tree, branches and cleaning the area around the sub station premises including two pole/four pole structures, complete all as specified and directed.
M&L trimming/cutting of tree branches to provide proper clerance around existing HT/LT over head line up to 5 lines with clearance of 3mtr on both the sides from center of OH line all as per technical requirement & including removing of cut tree branches from site and depositing at one place for burning/removing, complete all as specified and directed.
Restretching of existing aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc, complete all as specified and directed for any size of ACSR conductor. Note:- Each ACSR conductor in a circuit will be measured & paid sepretely.
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet steel of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 400 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including connection with LT cable with appropriate lugs, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 400 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 250 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 200 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 160 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 100 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 63 Amp, ultimate breaking capacity 10 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S&F in renewal of aluminium lugs, properly crimping and taping different colours, complete all as specified and dircted for the following size of cables: - 185 Sqmm
Supply only electrical insulating tape roll of length 25 metre and width 20 mm having high performance strength and good adhesive characteristics, complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .