Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.1 L+₹5,506.90 (0.92%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical L5 | |
| 5 | Rejected-Technical | - | Rejected-Technical L4 |
Tender Value
₹8.2 L
EMD Value
₹20,625
Closing Date
12 Dec 2024, 2:00 pmClosed
Executive Engineer
P H Division KWA Malaparamba
Deposit work PMGSY III Batch I 2023 24 Utility shifting along Puthiyedathu Thazham Chirakkuzhi Pavayil Cheerp Roadrevisedestimate Pipeline Work
2024_KWA_711519_1
EE/PHD/KKD/19/2024-25
Open Tender
Civil Works - Water Works
Item Rate
30 days
Chelannur
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,820
₹20,625
31 Jan 2025
3 Dec 2024
13 Dec 2024
3 Dec 2024
12 Dec 2024
3 Dec 2024
3 Dec 2024 - 12 Dec 2024
Amount
APP : B - Working charge
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
18.12.8:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore
OD83223/2024-2025:Providing interconnection from existing 90 mm PVC line to Newly laid 90 mm PVC line , rate including earth work excavation for tracing existing line , and interconnecting line , fencing , interconnection charge , Labour charge for fitting , testing line , cost of pipe specials etc complete
100.60.13.1.1:Providing 15mm (1/2 inch) house connection with 15mm water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5m using 20mm ( 1/2 inch ) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression / GM / Brass specials viz. brass ferrule, brass hexagonal nipple, GM full way wheel valve, bend, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.15.1.1:Providing additional length of house connection pipe using 20 mm (1/2 inch) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PN16 specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.
OD83224/2024-2025:Providing and fitting rect angular CI Surface box 30x20 cm size embeded in cement concrete of 1:2:4 , including fitting 200 mm PVC 6kg/cm2 covering pipe above the valve , earth work for locating valve , fitting surface box at correct position to operate the valve conveniently , rate including all labour and material charge etc complete
APP : A - Cost of Materials
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
OD83221/2024-2025:Supplying PVC Specials
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
OD83222/2024-2025:Supplying Tail Piece for valve
MUHAMMED UVAIS C H (BID ID -2014559)
Abc (BID ID -2015601)
SUBASH P K (BID ID -2015490)
jeshil.p (BID ID -2015470)
Bidder Name
jeshil.p
RAMACHANDRAN C K
SUBASH P K
MUHAMMED UVAIS C H
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .