| 1 | L1₹10.1 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹13.9 L+₹2.9 L (26.3%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹16.7 L+₹5.7 L (51.6%)Rejected-Finance | L3 | Rejected-Finance Due to L3 |
Tender Value
Refer Docs
EMD Value
₹39,800
Closing Date
19 Sept 2020, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAINTENANCE AND REPAIRS TO INTERNAL ELECTRIFICATION AND CONNECTED WORKS IN MAP QTRS AT AFS BIDAR.
2020_MES_371025_1
8232/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹39,800
Yes
5 Oct 2020
21 Aug 2020
21 Sept 2020
21 Aug 2020
19 Sept 2020
5 Sept 2020
Amount
S & F Switch piano flush, single pole, one way, 5/6 Amp, including taking down existing all as specified and directed.
S & F Ceiling rose surfaces bakelite 63.5 X 28mm three terminals including taking down existing all as specified and directed.
S & F switch socket outlet 3 Pin 5 Amp, flush type, including taking down existing all as specified and directed.
S & F switch socket outlet multipurpose, 3 Pin 15/16 and 3pin 5/6Amp, 240 Volt, controlled by one switch including taking down existing all as specified and directed.
S & F switch bell push piano, flush, single pole, 5/6 Amp, including taking down existing all as specified and directed.
S & F switch modular type single pole one way 6 Amp with all accessories including taking down existing all as specified and directed.
S & F switch modular type single pole one way 16 Amp with all accessories including taking down existing all as specified and directed.
S & F socket outlet 3 Pin 6 Amp modular type all accessories including taking down existing all as specified and directed.
S&F socket outlet multipurpose 3 Pin 16A modular type with all accessories including taking down existing all as specified and directed.
S&F Bell push modular type 6A with all accessories including taking down existing all as specified and directed.
S & F 240V, 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete including taking down existing all as specified and directed.
S & F RCBO 30 ma, having current carrying capacity 40 Amp, SPN including taking down existing all as specified and directed.
S & F MCB DB SPN 4 way, double door, including taking down existing all as specified and directed.
S & F MCB DB SPN 8 way, double door, including taking down existing all as specified and directed.
S & F MCB DB TPN 4 way, single door, including taking down existing all as specified and directed.
S & F MCB TPN 40 to 63 Amp 240 V 50 Hz AC Supply including taking down existing all as specified and directed.
S & F MCB TPN 6 to 32 Amp with proper size lugs aincluding taking down existing all as specified and directed.
S & F MCB SP 6 to 32 Amp including taking down existing all as specified and directed.
S & F MCB SPN 10 to 32 Amp 240 V 50 Hz AC Supply including taking down existing all as specified and directed.
S & F MCB SPN 40 to 63 Amp 240 V 50 Hz AC Supply including taking down existing all as specified and directed.
S & F bell AC 230 Volt Ding Dong type, 240 Volt AC supply, including taking down existing all as specified and directed.
S & F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium bldg security light luminaries with high power LED as light source of power 45 W, IP 66, system luminous efficacy >85 Lm/ W, life 50,000 hrs, surge protection 10 kV and zero maintenance including all light fittings etc. and connection from ceiling rose to light fitting by using three core 1.5 sq mm copper conductor cable complete including taking down existing all as specified and directed.
S & F MCCB 125 Amp 3 pole 25 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete including taking down existing all as specified and directed.
S & F MCCB 100 Amp 3 pole 25 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete including taking down existing all as specified and directed.
S & F MCCB 63 Amp 3 pole 16 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete including taking down existing all as specified and directed.
S & F fan regulator, AC, 230V, single pole electronic, step type, complete, including taking down existing all as specified and directed.
S & F Two module, Fan regulator, step type, AC ,230V, electronic, complete, including taking down existing all as specified and directed.
S & F One module, Fan regulator, step type, AC ,230V, electronic, complete, including taking down existing all as specified and directed.
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) compete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. all as directed.
Point wiring with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through in existing conduit and accessories, surface type on wall/ roof/ floor with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sqmm multistranded PVC insulated copper conductor cable for one light point /bell point /fan point controlled by one switch complete all as specified and directed.
All as per item No 30 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sqmm PVC insulated multistranded copper conductor cable all as directed.
All as per item No 30 here-in-before but for 5 Amp switch socket on independent board all as directed.
All as per item No 30 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable all as directed.
Sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through in existing conduit and accessories, one run of PVC insulated 4 sqmm copper conductor for earth continuity and taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through in existing conduit and accessories, one run of PVC insulated 6 sqmm copper conductor for earth continuity and taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 10sqmm, single core, PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through in existing conduit and accessories, one run of PVC insulated 10 sqmm copper conductor for earth continuity and taking down existing submain wiring complete all as specified and as directed. Note for item Nos. 34, 35 and 36: 2 runs 4/6/10sqmm single core copper conductor and 1 run of 4/6/10sqmm copper conductor earth wire will be measured as one unit
S & F 20/22 W LED Surface mounted, batten fixture, 1200mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink. The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K including taking down existing all as specified and directed.
S & F 10/12 W LED Surface mounted, batten fixture 600 mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink . The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K including taking down existing all as specified and directed.
Disconnection & taking down the unserviceable vintage high wattage Building security light fittings and Supply & fixing energy efficient Intergral type LED 70 W light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted on MCPCB and testing complete all as specified and directed
Disconnection & taking down the unserviceable GI bracket of size 40mm dia from the pole / building and M&L for street light bracket made out of 40mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding, drilling holes as required and fixing with flat iron clamps 50 x 6mm thick (2 Nos) with suitable nut, bolts and washers to steel tubular / concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc complete all as specified and directed
M.chandraiahsons
BHIMRAO PATIL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .